• Title/Summary/Keyword: synthetic wastewater

Search Result 340, Processing Time 0.023 seconds

Phosphorous Removal from Synthetic Wastewater Using a Continuous Flow Column Packed with Waste Lime Core (부산석회 Core로 충진된 연속식 칼럼을 이용한 인공폐수 내 인제거)

  • Lee Eui-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.709-714
    • /
    • 2006
  • The propose of this study was to investigate the feasibility of using waste lime core to remove phosphorus from wastewater in continuous flow reaction. The phosphorus was found to be removed from municipal wastewater by hydroxyapatite crystallization and precipation. Waste lime core size 1, 2 showed phosphorus removal rate of about 90% during early 11 hrs of run time. In addition, breakpoint time was decreased by increased inflow rate regardless of waste lime core size.

  • PDF

Study of Factors Influenced on denitrification in wastewater treatment (폐수처리 탈질 공정에 미치는 인자 연구)

  • Jeong, Gwi-Taek;Park, Seok-Hwan;Park, Jae-Hee;Bhang, Sung-Hun;Lim, Eun-Tae;Park, Don-Hee
    • KSBB Journal
    • /
    • v.23 no.6
    • /
    • pp.535-540
    • /
    • 2008
  • In this study, the effects of several factors such as initial nitrate concentration, C/N ratio, biomass amount and external carbon source on denitrification process were investigated using synthetic wastewater and sludge obtained from wastewater treatment facility. As a result, the condition of lower initial nitrate concentration was increased to the removal rate of nitrate than that of high concentration. The increases of C/N ratio and initial biomass amount were linearly enhanced the removal rate. The use of ethanol as external carbon source was shown the highest removal yield than that of others.

Applications of Ozone Micro- and Nanobubble Technologies in Water and Wastewater Treatment: Review (정수 및 폐수처리에서 오존 미세기포와 초미세기포 기술의 적용 : 리뷰)

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.481-490
    • /
    • 2017
  • Water and wastewater treatment has always been a challenging task due to the continuous increase in amount and the change in characteristics of the poorly biodegradable and highly colored organic matters, as well as harmful micro-organisms. Advanced techniques are therefore required to successfully remove these pollutants from water before reuse or discharge to receiving water bodies. Application of ozone, which is a powerful oxidant and disinfectant, alone or as part of advanced oxidation process depends on the complex kinetic reactions and the mass transfer of ozone involved. Micro- and nano bubbling considerably improves gas dissolution compared to conventional bubbles and hence mass transfer. It can also intensify generation of hydroxyl radical due to collapse of the bubbles, which in turn facilitates oxidation reaction under both alkaline as well as acidic conditions. This review gives the overview of application of micro- and nano bubble ozonation for purification of water and wastewater. The drawbacks of previously considered techniques and the application of the hydrodynamic ozonation to synthetic aqueous solutions and various industrial wastewaters are systematically reviewed.

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Factors affecting nitrite build-up in an intermittently decanted extended aeration process for wastewater treatment (하수처리를 위한 간헐 방류식 장기폭기 공정에서 아질산염의 축적에 영향을 미치는 인자)

  • Ahn, Kyu-Hong;Park, Ki-Young;Lee, Hyung-Jib
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.51-60
    • /
    • 1999
  • An intermittently-aerated, intermittently-decanted single-reactor process (KIDEA process : KIST intermittently decanted extended aeration process) was applied for nitrogen removal from wastewater. Synthetic wastewater with chemical oxygen demand (COD): nitrogen (N) ratio of approximately 5.25: 1 was used. The average COD removal efficiency reached above 95%, and under optimal conditions nitrogen removal efficiency also reached above 90%. This process consisted of 72 minute aeration, 48 minute settling and 24 minute effluent decanting with continuous feeding of influent wastewater from the bottom of the reactor, and did not require a separate anoxic mixing-phase. In this process, nitritation ($1^{st}$ step of nitrification) was induced but nitratation($2^{nd}$ step of nitrification) was suppressed. Main factors responsible for the accumulation of nitrite ion in the experimental condition were free ammonium and dissolved oxygen. This condition of nitrite build-up accelerated by continuous feed flow in the bottom of the KIDEA reactor because of high concentration of ammonia nitrogen in the influent. This research provides one of answers to control nitrate build-up.

  • PDF

Regeneration of nitrate and phosphate from toilet wastewater using waste alumina adsorbent for cultivation of Spirulina platensis

  • Lee, Sang-Jun;Park, Seonghwan;Noh, Won;Yeom, Dong-Hyuk;Kim, Sooyeon;Kim, Dae-wook;Kim, Jungmin
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.393-399
    • /
    • 2020
  • The use of different types of wastewater (WW) for the cultivation of microalgae and cyanobacteria during recent decades has provided important economic and environmental benefits. However, direct use of WW can lead to growth inhibition and biomass contamination. In the present study, we separated the key WW nutrients, namely nitrate and phosphate, by adsorption and regeneration and used the resulting regenerated water to cultivate the cyanobacterium Spirulina platensis. The adsorbent was granular γ-alumina derived from waste aluminum cans. This procedure recovered 19.9% of nitrate and 23.7% of phosphate from WW. The cyanobacterial cultures efficiently assimilated the nutrients from the medium prepared using regenerated WW, and the growth and nutrient uptake were similar to those in a synthetic medium. In addition, imposing nutrient limitations to increase carbohydrate productivity was easily achieved using regenerated wastewater nutrients, without requiring additional dilution or complex processing. In acute toxicity tests, the harvested biomass in a regenerated medium had similar toxicity levels compared to the biomass obtained from a synthetic medium. The proposed method of using regenerated WW to produce contamination-free biomass has broad potential applications.

An investigation into the performance of a high-speed synthetic fiber filter employing different types of coagulants (응집제에 따른 합성섬유 여재를 충진한 고속필터의 여과특성에 관한 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.125-139
    • /
    • 2017
  • In this paper, the performance of a synthetic fiber filter aimed at high-speed operation and dosed with different coagulants or filter aids was investigated. Without a coagulant, the filter efficiency was about 62% which was greatly enhanced when three types of coagulants namely PAC, Alum, and $FeCl_3$ were used. Among the coagulants tested, PAC was the most effective, giving 91% filter efficiency, followed by Alum with 90%, and $FeCl_3$ with 78%. PAC worked effectively at a very small range of dose, but Alum was relatively effective in a wide range of concentration. Compared with PAC and Alum, $FeCl_3$ provided more or less contant efficiency regardless of its dose but gave the poorest filter efficiency. Moreover, as the inflow turbidity increased, headloss increased and the efficiency decreased at any dose and type of coagulant. The headloss recorded in this particular synthetic fiber filter is not significant as compared to that observed in typical granular filters. The recovery of solids estimated after filter cleaning was about 80% for both PAC and Alum, but poorer at 72% in the case of $FeCl_3$ due to the heavy and large floc characteristics. The recurrence of filter efficiency verified through repetitive filter runs was found to be satisfactory.

Treatment of Ethylene Glycol in Polyester Weight Loss Wastewater(I) - Reaction Characteristics - (Polyester감량폐수 중에 존재하는 Ethylene Glycol의 처리(I) - 반응 특성 -)

  • Kim, Jeong-Mog;Huh, Man-Woo;Han, Myung-Ho
    • Textile Coloration and Finishing
    • /
    • v.8 no.5
    • /
    • pp.84-89
    • /
    • 1996
  • This study carried out batch and continuous experiments using calcium hydroxide as neutralization agent and immobilization media for removing the ethylene glycol in the pretreated polyester weight loss wastewater. The $TCOD_{Mn}$ concentration in the treated wastewater using culture of iramobilization and suspension for the synthetic wastewater were found as 650mg/l and 1,250mg/l after 48hours, respectively. SVI(Sludge Volume Index) and $TCOD_{Mn}$ concentration were 74 and 73mg/l at optimum F/M ratio, 1.32kg-TCO $D_{Mn}$ /day. kg-MLVSS. The $TCOD_{Mn}$ concentration and removal efficiency were 213mg/l and 93.5% by continuous experiments in the air-lift bioreactor, respectively. The $TCOD_{Mn}$ concentration was 82mg/l, and also the MLVSS concentration was 2,550mg/l, when the volumetric loading rate was 3.04kg-$TCOD_{Mn}/m^{2}$ day for real polyester weight loss wastewater.

  • PDF

Polyvinyl Alcohol 분해 공생 균주에 의한 염색 폐수 중의 PVA 제거

  • Kim, Chul Ki;Choi, Yong-Jin;Lee, Chul-Woo;Rim, Yeon-Taek;Ryu, Jae-Keun
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.1
    • /
    • pp.89-95
    • /
    • 1997
  • The current processer of the textile wastewater treatment are mostly consisted of a combination of a physico-chemical and a biological treatment. The overall efficiency of these processes is, however, assessed to be fairly low. It is even worse during the summer season when temperature of the wastewater rises above 40$\circ $C. Therefore, a feasible process of the textile wastewater treatment which can work efficiently at higher temperatures was investigated in this work. We used a bench scale reactor consisted of one 4 liter anaerobic and one 8 liter aerobic tank, and the thermophilic symbiotic PVA degraders, Pasteruella hemolytica KMG1 and Pseudomonas sp. KMG6 that had been isolated in our laboratory. In the preliminary flask experiments, we observed that the thermophilic symbiotic PVA degraders could not grow in the wastewater substrate. Then, we isolated the mutant strains by acclimating the KMG1and KMG6 strains to the wastewater medium. The mutant symbionts (KMG1-1 and KMG6-1) were isolated through 6 times successive transfers into the fresh wastewater medium after 5 days culture for each. The mutant strains obtained grew well in the mixed medium composed of 75% wastewater and 25% synthetic medium, and supplemented with 0.5% PVA as a sole carbon source. During the culture for 14 days at pH 7.0 and 40$\CIRC $C, the bacteria assimilated about 89% of the added PVA. The symbionts degraded equally well all the PVA substrates of different molecular weight (nd=500~30000). In contrast to the flask experiments, in the reactor system the mutant strains showed very low levels of the PVA and COD removal rates. However, the new reactor system with an additional aerobic tank attained 82% removal rate of COD, 94% of PVA degradation and 71% of color index under the conditions of 5% inoculm on the tank 2, incubation temperature of 40$\circ $C, dissolved oxygen level of 2~3 mg/l and retention time of 30 hours. This result ensures that the process described above could be an efficient and feasible treatment for the PVA contained textile wastewater at higher temperatures.

  • PDF

Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration (저압나노여과에 의한 각종 중금속의 제거 특성)

  • Oh, Jeong-Ik;Kim, Han-Seung;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.