• Title/Summary/Keyword: symmetry index

Search Result 104, Processing Time 0.024 seconds

Simultaneous Reduction of Contralateral Malar Complex in Cases of Unilateral Zygoma Bone Fracture (편측 관골 골절에서 동시 반대측 관골 축소술)

  • Kim, Peter Chan-Woo;Lee, Byung-Kwon;Bae, Ji-Suk
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.851-860
    • /
    • 2011
  • Purpose: Reduction by simply assembling bones is recognized as treatment for a zygoma fracture. However, in patients who originally had a protruding zygoma, the fractured parts look like malarplasty after the edema subsides, giving a soft impression which patients notice. Thus, we created symmetry through simultaneous contralateral malar reduction in a unilateral zygoma fracture. Methods: In this study, the patients who had surgery between July, 2008 and December, 2009 with admission were object. In 76 patients with a zygoma fracture, the patients with bilateral zygoma fractures were excluded. Among 48 patients who had a reduction only after a unilateral zygoma fracture, the patients hoping for a reduction of their rough protruding zygoma were analyzed with front cephalometry. The study progressed on 22 patients who had simultaneous contralateral malar reduction in a unilateral zygoma fracture with consent. After fixing the fracture, we did a straight zygoma osteotomy through a 1.5 cm intraoral incision. After that, we created symmetry with a special ruler and fixed the broken zygomatic arch with a screw and plate. We evaluated the facial index and satisfaction with a statistical analysis before and after the surgery. Results: In 22 patients, there was no reoperation except for 1 patient who had a zygoma fracture. None of the patients were treated for infection or hematoma. Two patients complained of paresthesia after the malar reduction operation, but this subsided in 4 months. Most of them were satisfied with the malar reduction, especially the women, and we obtained a better mid facial contour with decreased facial width ($p$ <0.05). Conclusion: Existing zygoma fracture surgery focuses on anatomical reduction. However, we need to have a cosmetic viewpoint in fractures as interests of face contour arise. Thus, contralateral malar reduction got a 4.7 (range 0~5) from patients who had malar reduction surgery in our hospital. Although adjusting to all zygoma fractures has limitations, it can be a new method in zygoma fractures when there are limited indications of protruding zygoma and careful attention is given to patients' high demands.

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Correction of Upper Lip Depression Using Conchal Cartilage Graft in Unilateral Cleft Lip Deformity (일측구순열변형에서 이갑개연골이식술을 이용한 상구순 함몰의 교정)

  • Han, Ki-Hwan;Yun, Sang-Ho;Yeo, Hyun-Jung;Kim, Jun-Hyung;Son, Dae-Gu
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: To correct the upper lip depression after the correction of unilateral cleft lip, autologous grafts such as bone, dermal, fascial grafts and fat injections or alloplastic implants are used. Transplanted bones, dermis and fascia have a tendency to be absorbed and have donor morbidity. Fat injections are absorbed inconsistently and alloplastic implants have problems such as foreign body reactions, protrusions and infections. Authors corrected the upper lip depression using conchal cartilage graft in unilateral cleft lip deformity and the results was analysed with photos. Methods: 26-unilateral cleft lip and 2-microform cleft lip cases, totally 28 cases were performed. Their mean age was 21.89 years. The male and female cases were 12 and 16, respectively. Under anesthesia (general: 18 cases and local: 10 cases), cavum conchae (n=8), cymba conchae (n=16) and whole conchae (n=4) were harvested. Transversely cut the margin of the obtained cartilage, we cut out the most bent portion and put a partial-thickness incision on concave surface in cases of excessive convexity. Then, we performed the onlay graft of the conchal cartilage via scar revision site in unilateral cleft lip and via the reconstruction site of the cupid bow in microform cleft lip. The augmentation of the upper lip was evaluated with photos. Adapting the baseline connecting between the both cheilions as a horizontal standard line, we measured the highest point among the tangents between the upper lip and nose (point a), the lowest point (point c), the middle point between a and c (point b) and the vertical line from the alare (point d) to the horizontal standard line. To assess the postoperative symmetry, we compared cleft side upper lip contour index (%) A,B,C,D=(a,b,c,d)-ch ${\times}$ 100/(ch-ch) and non-cleft side upper lip contour index (%) A',B',C',D'= (a',b',c',d')-ch ${\times}$ 100 / (ch-ch).h) Results: After the surgery, no complication was found except in one case which double layers graft performed in the cleft lip deformity, the lateral portion was protruded. The upper lip contour index, the difference of A and A' were-0.83%, and thus the mild depression was persisted. Difference of B and B', C and C', D and D' were 0.83%, 1.07%, 0.90%. There were statistically significant difference, and thus the depression of upper lip were improved generally. Conclusion: Authors performed the onlay graft of the conchal cartilage in unilateral cleft lip deformity and found that the depression of the upper lip was well corrected except the uppermost part when photogrammetrically analyzed.

A Study on the Body Surface Area of Korean Women (Part I) Body Surface Area and It's Rational Rate (한국여성의 체표면적에 관한 연구(제1보) -체포면적 및 그의 안분비율에 대하여-)

  • Im Soon;Cha Ok Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.3 s.28
    • /
    • pp.277-284
    • /
    • 1988
  • The purpose of study was to measure to body Surface area and the rational rate of Korean adult's women. The subjects are 20 years old to 49 years old women (Their bust width ranges from 74.5 to 101.5 cm, the height from 144.6 to 163.3 cm, the weight from 44.2 to 74.0 kg, Rohrer Index from 1. 02 to 1. 89). As the experimental method, both the gypsum method, by which the shape of body can be copied as it is, and weighing method, from which planed body surface area can be measured with consistant thickness of polypropylene film used. The results were obtained as follows. 1. After dividing the Korean adult's women into four groups (single and married women in their twenties, those in their thirties, those in their fourties). The change of body surface area was reviewed in accordance with age groups. No great difference among age group was showed in whole body surface area. 2. average value of body surface area is 1, 514m^2 and the part of trunk shows the biggest difference to the age groups. 3. After dividing the middle of body into two groups, the relation of symmetry of each parts is reviewed with difference in body surface area. The results shows that the part of head & neck and lower limbs are symmetrical. The part of trunk and upper limbs are unsymmetrical. 4. Regional rates of each part of whole body surface area are follows. head $4.98\%$, each-lobes $0.46\%$, neck $2.01\%$, face$2.48\%$, upper trunk $19.64\%$, lower trunk $13.91\%$, upper armpits $1.76\%$, lower armpits $12.52\%$, hands $4.64\%$, thighs $18.89\%$, lower legs$13.10\%$, feet $6.01\%$.

  • PDF

A Novel Asymmetric Vertical Directional Coupler Switch (비대칭 수직 방향성 결합기 스위치)

  • Jo, Seong-Chan;Jeong, Byeong-Min;Kim, Bu-Gyun;Choe, Ji-Yeon;Hwang, Hyeong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.31-40
    • /
    • 2002
  • We propose a novel ultra-short asymmetric vertical directional coupler switch (VDCS) with high extinction ratios larger than 30㏈ composed of switching operation induced section (SOIS), extinction ratio adjusted section (ERAS), and extinction ratio enhanced section (ERES). In this VDCSs, switching operation is achieved by changing the refractive index of one core in SOIS. The improvement of extinction ratios larger than 30㏈ for both cross and bar states is achieved by controlling the asymmetry of refractive indices between both cores in ERES. After propagating through ERAS with symmetry in the structure, different extinction ratios between cross and bar states at the end of SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of cores to have the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines to achieve high extinction ratios with large tolerances are presented.

Infrared Spectroscopic Studies on Dickite and Pyrophyllite: Far-IR and Mid-IR Regions (딕카이트와 엽납석에 대한 적외선 분광학적 연구: 원적외선 및 중간적외선 영역)

  • 추창오;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.119-127
    • /
    • 2001
  • FTIR spectroscopic study was undertaken on dickite and pyrophyllite with Si and Al cations in the far-infrared(Far-IR) and mid-infrared (Mid-IR) regions, respectively. Attempts were made to present bonding information and make assignments on the absorption bands of dickite in the Far-IR region. Dickites contain a small proportions or kaolinite or nacrite layers. FTIR can be used as a potential tool for characterizing the presence of mixed-layer with different polytypes of the kaolin minerals. There is no clear relationship between Hinckley index and crystallinity of dickite. Although pyrophyllite shows a strong OH stretching band at 3673-3676 $cm^{-1}$ / corresponding to an inner hydroxyl group, the weak band at $3645-3648 cm^{-1}$ seems to be due to the symmetric vibration if the symmetry of the structure is not ideal, probably due to the presence of trace Fe or mixture phases of 1Tc and 2M polytypes.

  • PDF

Effects of the Random Fluctuation in Grating Period on the Characteristics of DFB Lasers (회절격자 주기의 랜덤 변이가 DFB 레이저 특성에 미치는 영향)

  • Han, Jae-Woong;Kim, Sang-Bae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.76-85
    • /
    • 2000
  • Effects of the random fluctuation in grating half-period have been studied by an effective index transfer matrix method in DFB lasers. The laser facets are assumed to be perfectly antireflection coated, and the period fluctuation is modeled as a Gaussian random variable. The random fluctuation breaks spectral symmetry in both uniform-grating and quarter-wavelength -shifted(QWS) DFB lasers, and decreases the effective coupling coefficient. This leads to increased average mirror loss of ${\pm}$1 modes and reduced stopband width in uniform grating DFB lasers, and degradation in the wavelength accuracy and the single mode stability in QWS-DFB lasers. Threshold gain difference decreases with increasing period fluctuation irrespective of grating coupling coefficient in QWS-DFB lasers, while spatial hole-burning effect is exacerbated or alleviated when the normalized coupling coefficient is lower and higher than 1.5, respectively.

  • PDF

Classification accuracy measures with minimum error rate for normal mixture (정규혼합분포에서 최소오류의 분류정확도 측도)

  • Hong, C.S.;Lin, Meihua;Hong, S.W.;Kim, G.C.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.4
    • /
    • pp.619-630
    • /
    • 2011
  • In order to estimate an appropriate threshold and evaluate its performance for the data mixed with two different distributions, nine kinds of well-known classification accuracy measures such as MVD, Youden's index, the closest-to- (0,1) criterion, the amended closest-to- (0,1) criterion, SSS, symmetry point, accuracy area, TA, TR are clustered into five categories on the basis of their characters. In credit evaluation study, it is assumed that the score random variable follows normal mixture distributions of the default and non-default states. For various normal mixtures, optimal cut-off points for classification measures belong to each category are obtained and type I and II error rates corresponding to these cut-off points are calculated. Then we explore the cases when these error rates are minimized. If normal mixtures might be estimated for these kinds of real data, we could make use of results of this study to select the best classification accuracy measure which has the minimum error rate.

Optical Properties of Y3Al5O12;Ce3+,Pr3+ Transparent Ceramic Phosphor for High Power White Lighting (고출력 백색 광원용 Y3Al5O12;Ce3+,Pr3+ 투명 세라믹 형광체의 광학특성)

  • Kang, Taewook;Lim, Seokgyu;Kim, Jongsu;Jeong, Yongseok
    • Korean Journal of Materials Research
    • /
    • v.29 no.2
    • /
    • pp.116-120
    • /
    • 2019
  • We prepared $Y_3Al_5O_{12};Ce^{3+},Pr3^{+}$ transparent ceramic phosphor using a solid state reaction method. By XRD pattern analysis and SEM measurement, our phosphors reveal an Ia-3d(230) space group of cubic structure, and the transparent ceramic phosphor has a polycrystal state with some internal cracks and pores. In the Raman scattering measurement with an increasing temperature, lattice vibrations of the transparent ceramic phosphor decrease due to its more perfect crystal structure and symmetry. Thus, low phonon generation is possible at high temperature. Optical properties of the transparent ceramic phosphor have broader excitation spectra due to a large internal reflection. There is a wide emission band from the green to yellow region, and the red color emission between 610 nm and 640 nm is also observed. The red-yellow phosphor optical characteristics enable a high Color Rendering Index (CRI) in combination with blue emitting LED or LD. Due to its good thermal properties of low phonon generation at high temperature and a wide emission range for high CRI characteristics, the transparent ceramic phosphor is shown to be a good candidate for high power solid state white lighting.

Effects of Isometric Exercise on Muscle Activity and Body Balance Ability in Asymmetrical Walkers

  • Young Ae, KWON;Mun Young, HEO;Jeong Weon, KIM;Hwang Woon, MOON
    • Journal of Sport and Applied Science
    • /
    • v.7 no.1
    • /
    • pp.21-29
    • /
    • 2023
  • Purpose: This study was to investigate the effects of isometric exercise on muscle activity and body balance ability in asymmetrical walkers. Research design, data, and methodology: Twenty gait asymmetry people were divided to unilateral exercise group (UG, n=10) and bilateral exercise group (BG, n=10). UG were performed unilateral exercise for 60 minutes, three times a week, and 16 weeks, and BG were performed one side and then the other side alternately for 60 minutes, three times a week, and 16 weeks. Muscle activity and body balance ability were measured before, after 4 and 16 weeks isometric exercise. Moreover, SI (symmetry index; SI) was calculated from the measured value of SL (step length). Statistical analyses were conducted using one-way ANOVA and two-way ANOVA with repeated measures, a paired t-test, and multiple comparisons according to Scheffe. Results: In the muscle activity, ST decreased significantly in short step length(S-SL) and BG of LS compared to before isometric exercise(p<.05), and GCM decreased significantly in BG of S-SL(p<.05). As for body balance ability, the mSEBT-A difference between L-SL and S-SL was decreased significantly in UG(p<.05). And the respective total scores of L-SL and S-SL, mSEBT-PM and mSEBT-PL were increased significantly in BG(p<.05). Conclusions: As a result, in this study above, it was confirmed that isometric exercise improved muscle activity and body balance ability in asymmetrical walkers.