• Title/Summary/Keyword: switching power loss

Search Result 780, Processing Time 0.035 seconds

A Study on the Output Noise Reduction of 3-Phase Multilevel Inverter (3상 멀티레벨 인버터 출력노이즈 저감에 관한 연구)

  • Kim, Soo-Hong;Jin, Kang-Hwan;Kin, Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.101-103
    • /
    • 2007
  • Since they use the low switching frequency in multilevel inverter systems, they generate the high low frequency harmonic components. Generally, LC filter is used at the output terminal of inverter systems to solve this problem. But it causes a voltage drop at the output terminal by use of damping resistors, and causes the problem in which system efficiency decreases due to power loss of the damping resistor. In this paper, we proposed an output filter design method for NPC three-level inverter systems with low switching frequency. And we analyzed the efficiency of the proposed filter system, and the effectiveness of the proposed system is verified by simulation and experimental results.

  • PDF

Thermal analysis of the active-front-end rectifier for solid-state-transformer applications (반도체 변압기용 AFE 정류기의 열해석 연구)

  • WANG, SHANSHAN;Kang, Kyoung Pil;Baek, Ju Won;Kim, juyong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.435-436
    • /
    • 2017
  • This papaer is study on thermal analysis of the active-front-end(AFE) rectifier for solid-state-transformer(SST) applications. finite element analysis simulation model is combined by switching component model, power diode and heat-sink model. thermal model is calculated by computer program and feedback the result. using simulation result analysis switching loss and compare to thermal diffusion of the heat in the model for steady-state operation.

  • PDF

Switching Loss and Performance Analysis of the Buck Converter using Si and SiC devices (Si 및 SiC 소자를 이용한 벅 컨버터의 스위칭 손실 및 성능 분석)

  • Lim, J.W.;Choe, J.M.;Cho, Y.H.;Cheo, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.411-412
    • /
    • 2014
  • In this paper, the switching losses and performances of Silicon Carbide(SiC) and Silicon based on the MOSFETs have been compared. To do this experiment, the buck converter using both SiC and Si devices have been built and tested. As a result, it has been confirmed that the converter with SiC devices shows better efficiency and performance compared with the converter using Si devices.

  • PDF

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

A Study on Output Voltage Stabilization of 20W Class Multi-output QR Flyback Converter for Auxiliary Power (20W급 보조전원용 다출력 QR 플라이백 컨버터의 출력전압 안정화에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Kim, Hyun Bae;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.157-160
    • /
    • 2021
  • In this paper, a 20W class multi-output QR flyback converter for auxiliary power supply was designed to stabilize 4 output voltages, and the efficiency and load characteristics were compared and analyzed. It was checked if each output affects other output characteristics through experiment. As a result, the experimental circuit reached a high efficiency of 82.5% or more at a load power of over 20W, and the maximum power loss was 2.6W. Consequently, it was confirmed that all of 4 output voltages of the multi-output QR flyback converter constructed in this paper were stabilized within 0.5% in full-load range, and each output was independently controlled in an electrically isolated state.

A Study on the efficiency analysis of CCM boost converter (전류연속모드 승압형 컨버터의 효율 분석에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Lee, Eun-Young;Kwon, Soon-Do;Cho, Kyu-Man;Eom, Tae-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.920-921
    • /
    • 2008
  • This paper presents the efficiency analysis of CCM(Continuous Current Mode) boost converter. A thorough efficiency analysis of a boost converter taking into account the conduction losses, the diode power loss, the switching losses, the gate-drive loss and the capacitive switching loss, for both continuous conduction mode is presented.

  • PDF

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

A Study on Reactor Capacitance Estimation Algorithm and 5kW Plasma Power Supply Design for Linear Output Control of Wide Range (넓은 범위의 선형 출력 제어를 위한 5kW 플라즈마 전원장치 설계 및 반응기 커패시턴스 추정 알고리즘의 관한 연구)

  • Noh, Hyun-Kyu;Lee, Jun-Young;Kim, Min-Jea
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • This work suggests a study on 5 kW plasma power supply design and reactor capacitance estimation algorithm for a wide range of linear output control to operate a plasma reactor. The suggested study is designed to use a two-stage circuit and control the full-bridge circuit of the two-stage circuit using the buck converter output voltage of the single-stage circuit. The switching frequency of the full-bridge circuit is designed to operate through high-frequency switching and obtain maximum output using LC parallel resonance. Soft switching technique(ZVS) is used to reduce the loss caused by high-frequency switching, and duty control of the buck converter is applied to control a wide range of linear output. The internal capacitance of the reactor cannot easily be extracted, and thus, the reactor cannot be operated in an optimized resonant state. To address this issue, this work designs the internal capacitance of the reactor such that estimations can be performed with the developed reactor capacitance estimation algorithm applied to the internal capacitance of the reactor. A 5 kW plasma power supply is designed for a wide range of linear output control, and the validity of the study on the reactor capacitance estimation algorithm is verified.

A Parallel Hybrid Soft Switching Converter with Low Circulating Current Losses and a Low Current Ripple

  • Lin, Bor-Ren;Chen, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1429-1437
    • /
    • 2015
  • A new parallel hybrid soft switching converter with low circulating current losses during the freewheeling state and a low output current ripple is presented in this paper. Two circuit modules are connected in parallel using the interleaved pulse-width modulation scheme to provide more power to the output load and to reduce the output current ripple. Each circuit module includes a three-level converter and a half-bridge converter sharing the same lagging-leg switches. A resonant capacitor is adopted on the primary side of the three-level converter to reduce the circulating current to zero in the freewheeling state. Thus, the high circulating current loss in conventional three-level converters is alleviated. A half-bridge converter is adopted to extend the ZVS range. Therefore, the lagging-leg switches can be turned on under zero voltage switching from light load to full load conditions. The secondary windings of the two converters are connected in series so that the rectified voltage is positive instead of zero during the freewheeling interval. Hence, the output inductance of the three-level converter can be reduced. The circuit configuration, operation principles and circuit characteristics are presented in detail. Experiments based on a 1920W prototype are provided to verify the effectiveness of the proposed converter.

Performance Improvement of a Buck Converter using a End-order Space Dithered Sigma-Delta Modulation based Random PWM Switching Scheme (2차 Space Dithered Sigma-Delta Modulation 기반의 Random PWM 스위칭 기법을 이용한 강압형 DC-DC 컨버터의 성능 개선)

  • Kim, Seo-Hyeong;Ju, Seong-Tak;Jung, Hea-Gwang;Lee, Kyo-Beum;Jung, Gyu-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2009
  • This paper proposes the 2nd-order SDSDM (Space Dithered Sigma-Delta Modulation) for performance improvement of a buck converter. The PWM (Pulse Width Modulation) has a drawback in that power spectrum tends to be concentrated around the switching frequency. The resulting harmonic spikes cause a EMI(Electromagnetic Interference) and switching loss in semiconductor, etc. The 1st-order SDSDM scheme is a kind of DSDM for reducing these harmonic spikes. In this scheme, a switching frequency is spread through random dither generator placed on input part. In experimental result, the proposed 2nd-order SDSDM is confirmed by applying to a buck converter.