• Title/Summary/Keyword: switching failures

Search Result 54, Processing Time 0.027 seconds

MRFR - Multipath-based Routing Protocol with Fast-Recovery of Failures on MANETs

  • Ngo, Hoai Phong;Kim, Myung Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3081-3099
    • /
    • 2012
  • We propose a new multipath-based reliable routing protocol on MANETs, Multipath-based Reliable routing protocol with Fast-Recovery of failures (MRFR). For reliable message transmission, MRFR tries to find the most reliable path between a source and a destination considering the end-to-end packet reception reliability of the routes. The established path consists of a primary path that is used to transmit messages, and the secondary paths that are used to recover the path when detecting failures on the primary path. After establishing the path, the source transmits messages through the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to locally recover the route failure, the proposed protocol can handle the dynamic topological change of the MANETs efficiently. The simulation result using the QualNet simulator shows that the MRFR protocol performs better than other protocols in terms of the end-to-end message delivery ratio and fault-tolerance capability.

An Evolution of Reliability of large Scale Software of a Switching System (대형 교환 시스템의 소프트웨어 신뢰도 성장)

  • Lee, J.K.;Shin, S.K.;Nam, S.S.;Park, K.C.
    • Electronics and Telecommunications Trends
    • /
    • v.14 no.4 s.58
    • /
    • pp.1-9
    • /
    • 1999
  • In this paper, we summarize the lessons learned from the applications of the software reliability engineering to a large-scale software project. The considered software is the software system of the TDX-10 ISDN switching system. The considered software consists of many components, called functional blocks. These functional blocks serve as the unit of coding and test. The software is continuing to be developed by adding new functional blocks. We are mainly concerned with the analysis of the effects of these software components to software reliability and with the analysis of the reliability evolution. We analyze the static characteristics of the software related to software reliability using failure data collected during system test. We also discussed a pattern which represents a local and global growth of the software reliability as version evolves. To find the pattern of software of the TDX-10 ISDN system, we apply the S-shaped model to a collection of failure data sets of each evolutionary version and the Goel-Okumoto (G-O) model to a grouped overall failure data set. We expect this pattern analysis will be helpful to plan and manage necessary human/resources for a new similar software project which is developed under the same developing circumstances by estimating the total software failures with respect to its size and time.

Evaluation of Winding Insulation of IGBT PWM Inverter-Fed Low-Voltage Induction Motors

  • Park Doh-Young;Hwang Don-Ha;Kim Yong-Joo;Kang Do-Hyun;Lee Young-Hoon;Kim Dong-Hee;Lee In-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.470-474
    • /
    • 2001
  • IGBT inverters have switching rise times of 0.2-2 $\mu$ sec, and have been believed to cause insulation stresses and premature motor failures. Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted many concerns due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 19 low-voltage induction motors are presented. Different types of insulation techniques are applied to 19 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages are obtained.

  • PDF

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

A Study on the Insulation Performance Improvement of Induction Motors Fed by IGBT PWM Inverter (IGBT PWM 인버터 구동 유도전동기의 절연성능 향상기술 연구)

  • Hwang D.H.;Park D.Y.;Kim Y.J.;Lee Y.H.;Kim D.H.;Lee I.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.335-339
    • /
    • 2001
  • The recent advancements in power electronic switching devices have enabled high frequency switching operation and have improved the performance of pulse-width modulated (PWM) inverters for driving induction motors. But, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter. In this paper, the test results for evaluation on the stator winding insulation of low-voltage induction motors for IGBT PWM inverter applications are presented. The insulation characteristics are analyzed with partial discharge and dissipation factor tests. Also, insulation breakdown tests by switching pulse voltage are performed. An effective insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

Improving the Overall Efficiency for DC/DC Converter with LoV-HiC System

  • Han, Dong-Hwa;Lee, Young-Jin;Kwon, Wan-Sung;Bou-Rabee, Mohammed A.;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.418-428
    • /
    • 2012
  • It is very important to improve the overall efficiency of systems with a source of power that has low-voltage high-current terminal characteristics such as fuel cells. A resonant converter is required for high efficiency systems. However, the peak value of the switches current is large in a resonant converter. This peak current requires a large number of switches and results in system failures. In this paper, an analysis and experiments of a resonant isolation push-pull converter are performed. A switching loss analysis is performed in order to compare losses between a resonant push pull converter and a hard switching push-pull converter. Specially, the conduction loss is studied based on the ratio between the resonant frequency and the switching frequency. In addition, a method for improving the efficiency is implemented with conventional HF insolation converters.

Large-area imaging evolution of micro-scale configuration of conducting filaments in resistive switching materials using a light-emitting diode

  • Lee, Keundong;Tchoe, Youngbin;Yoon, Hosang;Baek, Hyeonjun;Chung, Kunook;Lee, Sangik;Yoon, Chansoo;Park, Bae Ho;Yi, Gyu-Chul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.285-285
    • /
    • 2016
  • Resistive random access memory devices have been widely studied due to their high performance characteristics, such as high scalability, fast switching, and low power consumption. However, fluctuation in operational parameters remains a critical weakness that leads to device failures. Although the random formation and rupture of conducting filaments (CFs) in an oxide matrix during resistive switching processes have been proposed as the origin of such fluctuations, direct observations of the formation and rupture of CFs at the device scale during resistive switching processes have been limited by the lack of real-time large-area imaging methods. Here, a novel imaging method is proposed for monitoring CF formation and rupture across the whole area of a memory cell during resistive switching. A hybrid structure consisting of a resistive random access memory and a light-emitting diode enables real-time monitoring of CF configuration during various resistive switching processes including forming, semi-forming, stable/unstable set/reset switching, and repetitive set switching over 50 cycles.

  • PDF

Reliability Modeling and Analysis for a Unit with Multiple Causes of Failure (다수의 고장 원인을 갖는 기기의 신뢰성 모형화 및 분석)

  • Baek, Sang-Yeop;Lim, Tae-Jin;Lie, Chang-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.21 no.4
    • /
    • pp.609-628
    • /
    • 1995
  • This paper presents a reliability model and a data-analytic procedure for a repairable unit subject to failures due to multiple non-identifiable causes. We regard a failure cause as a state and assume the life distribution for each cause to be exponential. Then we represent the dependency among the causes by a Markov switching model(MSM) and estimate the transition probabilities and failure rates by maximum likelihood(ML) method. The failure data are incomplete due to masked causes of failures. We propose a specific version of EM(expectation and maximization) algorithm for finding maximum likelihood estimator(MLE) under this situation. We also develop statistical procedures for determining the number of significant states and for testing independency between state transitions. Our model requires only the successive failure times of a unit to perform the statistical analysis. It works well even when the causes of failures are fully masked, which overcomes the major deficiency of competing risk models. It does not require the assumption of stationarity or independency which is essential in mixture models. The stationary probabilities of states can be easily calculated from the transition probabilities estimated in our model, so it covers mixture models in general. The results of simulations show the consistency of estimation and accuracy gradually increasing according to the difference of failure rates and the frequency of transitions among the states.

  • PDF

Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재사고 사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Nam-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

Negative Emotions and Coping Behaviors of Passenger in the Airline Industry, Vietnam

  • HOANG, Canh Chi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.865-874
    • /
    • 2020
  • In Vietnam, the airline service sector plays an important economic role. However, it is a complicated industry that is open to failures. Negative emotions are an essential variable for the airline service industry because they can trigger a variety of coping behaviors that affect consumer loyalty as well as the image and reputation of the airline service providers. However, negative emotions and the accompanying coping behaviors are often investigated partially or as separate issues, thus leading to an incomplete understanding. This study is conducted to fill this gap by proposing and testing the causal relationship between negative emotions (anger, frustration, regret) and coping behaviors (complaint, negative word-of-mouth (WOM), and switching intention) in the context of the airline industry. Eight research hypotheses are tested. Using the partial least squares structural equation modeling (PLS-SEM) on a sample of 587 passengers in Vietnam, the empirical results show that anger and frustration influence complaints, negative WOM, and switching intention, while regret leads to switching intention and negative WOM. Thus, the research has important academic and practical implications. The empirical outcome could be of major importance for airline companies in planning to provide new services and achieve high performance in the long run.