• 제목/요약/키워드: switch control

검색결과 1,253건 처리시간 0.029초

원자력 발전소 주 제어반의 제어 스위치 배치에 대한 인지적 수행도 평가 (A Cognitive Evaluation of Hand Switch Layouts in the Main Control Board of Nuclear Power Plants)

  • 변승남;이동훈
    • 대한산업공학회지
    • /
    • 제26권2호
    • /
    • pp.136-145
    • /
    • 2000
  • The objective of this study is to evaluate the human performance relating to the layouts of the two different hand switch types with two and three buttons in the nuclear power plants. Using a computer simulation, the cognitive performance for the hand switch layouts was measured on the basis of response and task completion times. Comparative analyses were performed with three different layouts representing the current switch arrangements in the Yonggwang nuclear plants 5 and 6 and Ulchin 3 and 4, respectively. Statistical analyses revealed that the performance of the two-buttoned switch layouts was found to be better than those of the three-buttoned switch. Furthermore, the superiority of the two-buttoned switch type is consistent regardless of various layout types. These results imply that the difference of the cognitive performance can be attributable to the switch types rather than to the switch layouts. Therefore, from the cognitive perspective, the two-buttoned switch type is recommended for future power nuclear plants.

  • PDF

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

The Function of Multiple Pribnow Box on the Aerobic-Anaerobic Switch Control of aeg-46.5 Gene Expression

  • 강인오;정연주;최무현
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.903-908
    • /
    • 2001
  • The gene aeg-46.5, which is expressed under anaerobic condition, has putative triple -10 regions and four transcription start sites. The mRNA transcription level and its start point change depending on the aerobic/anaerobic growth condition. RNA polymerase and its regulatory proteins must choose which of three -10 region to use. The putative triple 10 region was mutated to make only one of them function with consensus -10 region sequence (TATAAT) and the other two as non-functional region. The results show that the second and third -10 regions are used for the aerobic/anaerobic expression. The third -10 region is responsible for the high aerobic to anaerobic switch ratio. This suggests that only the last two of the putative triple -10 region have functions on aeg-46.5 gene expression switch control. The phenotype of the mutated promoter was tested in the wild type cell and narL - cell. The results indicate that the control by NarL is independent from the selection of -10 region. The expression patterns on multi-copy plasmids and on single-copy chromosome were compared. These results show that the aerobic/anaerobic switch control of aeg-46.5 is through the choice of -10 region. The mechanism of choosing different -10 region remains to be seen.

ABR 트랙픽 제어를 위한 버퍼 readout 스케쥴링 (A buffer readout scheduling for ABR traffic control)

  • 구창회;이재호
    • 전자공학회논문지S
    • /
    • 제34S권11호
    • /
    • pp.25-33
    • /
    • 1997
  • The end-to-end rate-based control mechanism is used for the flow control of the ABR service to allow much more flexibility in ATM switching system. To accommodate the ABR service effciently many algorithms such as EFCI, EPRCA, ERICA, and CAPC2 have been proposed for the switch algorithm. ABR cells and related RM cells are received at the ATM switch fabric transparently without any processing. And then cells received from the traffic source are queued in the ABR buffer of switching system. The ABR buffer usually has some thresholds for easy congestion control signal transmission. Whatever we use, therefore, these can be many ABR traffic control algorithms to implement the ABR transfer capability. The genertion of congestion indicate signal for ABR control algorithms is determined by ABR buffer satus. And ABR buffer status is determined by ABR cells transfer ratio in ATM switch fabrics. In this paper, we presented the functional structures for control of the ABR traffic capability, proposed the readout scheduling, cell slot allocation of output link and the buffer allocation model for effective ABR traffic guranteeing with considering CBR/VBR traffics in ATM switch. Since the proposed readout scheduling scheme can provide more avaliable space to ABR buffer than existing readout scheduling scheme, generation rate of a SEND signal, that is, BCN signal in destination node can be increased for ABR call connection. Therefore, the proposed scheme, in this paper, can be appropriate as algorithm for effective ABR traffic service on output link of ATM switching node.

  • PDF

LCOS기반의 파장선택스위치 빔제어용 컴퓨터 생성 홀로그램 (Computer Generated Hologram for Beam Control of LCOS based Wavelength Selective Switch)

  • 이용민;한창호
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.744-749
    • /
    • 2016
  • 본 논문은 차세대 ROADM을 구성하는 핵심기술인 LCOS를 이용한 파장선택 스위치에서 LCOS 소자의 빔 제어방법으로 컴퓨터 생성 홀로그램 설계에 관한 논문이다. LCOS 소자를 이용한 빔 제어방법으로 일반적으로 grating 패턴을 사용하지만 본 논문에서는 컴퓨터 생성 홀로그램을 도입하여 보다 높은 광효율의 파장선택 스위치 구현이 가능하도록 하였다. LCOS 소자의 위상변조 특성을 이용하여 5개의 출력 포트와 40 채널의 다중파장의 빔 제어를 할 수 있는 파장선택 스위치의 홀로그램 설계방법을 제시하였다. Gerchberg-Saxton 알고리즘을 적용한 멀티레벨 위상변조 홀로그램을 설계하였으며 다른 출력 포트와 채널을 갖는 파장선택 스위치 시스템에도 쉽게 적용이 가능하다. 타겟 이미지의 밝기정보를 사전에 입력하고 역프리에 변환을 통해 위상정보를 추출하여 홀로그램에 저장한 후 임의의 광원의 밝기정보를 합성하여 프리에 변환하는 방법으로 타겟 이미지의 밝기정보를 예측하는 방법을 사용한다. 5개의 출력포트용 홀로그램을 제작하여 검증실험장치의 재생 이미지의 출력특성을 통해 본 연구방법으로 설계된 홀로그램의 유용성을 검증하였고 40채널 파장선택 스위치 제어용 홀로그램 설계방법을 제시하였다.

저압직류용 하이브리드 차단기 (Hybrid LVDC Circuit Breakers)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.489-497
    • /
    • 2022
  • This work investigates the commutation characteristics of the current flowing through an electrical-contact-type switch to the semiconductor switch branch during the breaking operation of hybrid DC switchgear. A simple, reliable, low-cost natural commutation method is proposed, and the current commutation characteristics are analyzed in accordance with the conduction voltage drop of the semiconductor switch branch through experiments. A prototype 400 V/10 A class natural commutation type hybrid DC switchgear is set up. Its performance is verified, and its characteristics are analyzed.

주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가 (An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants)

  • 변승남
    • 대한산업공학회지
    • /
    • 제26권1호
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF

Z-Wave Mesh Network 방식을 이용한 홈네트워크용 통합 디밍스위치의 구현 (Implementation of Integration Dimming Switch for Home Network Using Z-Wave Mesh Network)

  • 황기현;설재훈
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1198-1206
    • /
    • 2011
  • 본 논문에서 개발한 Z-Wave Mesh Network 방식을 이용한 홈네트워크 통합 디밍스위치는 현재 홈 네트워크 기술이 적용된 아파트를 대상으로 설치가 되고 있는 네트워크 방식의 스위치로써, 조명스위치 사용에 대한 시공자 설비의 편의성, 사용자의 조작 편의성 제공과 동체감지센서 및 광세기 검출센서를 이용한 조명의 효율적 제어를 통한 전력절감 효과가 기대되는 유무선 네트워크가 가능한 지능형 통합디밍 조명스위치이다. 본 논문에서 개발한 통합 디밍스위치의 유용성을 평가하기 위하여 실험시스템을 구현하였고, 부하성능 평가, 조명제어, 통신속도 면에서 우수한 성능을 보였다.

4스위치 3상 BLDC 전동기의 토크 리플 저감을 위한 전류제어 알고리즘 (A Current Control Algorithm for Torque Ripple Reduction of Four-Switch Three-Phase Brushless DC Motors)

  • 박상현;김태성;이병국;현동석
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.126-133
    • /
    • 2004
  • 본 연구에서는 저 비용 응용분야에 적합한 4스위치 3상 BLDC 전동기의 새로운 전류 제어 알고리즘을 제안하였다. 4스위치 시스템에서 빠른 속도 및 토크 응답 그리고 적은 토크 리플과 같은 좋은 동작 특성을 얻기 위한 기준 전류 발생 기법을 제안하였다. 특히, 제안한 기법은 전류 전환시 발생되는 토크 리플을 현저히 저감시켜 4스위치 시스템을 산업 응용 분야에 보다 널리 적용할 수 있을 것으로 기대한다.