• Title/Summary/Keyword: switch control

Search Result 1,253, Processing Time 0.03 seconds

A Cognitive Evaluation of Hand Switch Layouts in the Main Control Board of Nuclear Power Plants (원자력 발전소 주 제어반의 제어 스위치 배치에 대한 인지적 수행도 평가)

  • Byun, Seong-Nam;Lee, Dong-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.136-145
    • /
    • 2000
  • The objective of this study is to evaluate the human performance relating to the layouts of the two different hand switch types with two and three buttons in the nuclear power plants. Using a computer simulation, the cognitive performance for the hand switch layouts was measured on the basis of response and task completion times. Comparative analyses were performed with three different layouts representing the current switch arrangements in the Yonggwang nuclear plants 5 and 6 and Ulchin 3 and 4, respectively. Statistical analyses revealed that the performance of the two-buttoned switch layouts was found to be better than those of the three-buttoned switch. Furthermore, the superiority of the two-buttoned switch type is consistent regardless of various layout types. These results imply that the difference of the cognitive performance can be attributable to the switch types rather than to the switch layouts. Therefore, from the cognitive perspective, the two-buttoned switch type is recommended for future power nuclear plants.

  • PDF

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

The Function of Multiple Pribnow Box on the Aerobic-Anaerobic Switch Control of aeg-46.5 Gene Expression

  • Gang, In O;Jeong, Yeon Ju;Choe, Mu Hyeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.903-908
    • /
    • 2001
  • The gene aeg-46.5, which is expressed under anaerobic condition, has putative triple -10 regions and four transcription start sites. The mRNA transcription level and its start point change depending on the aerobic/anaerobic growth condition. RNA polymerase and its regulatory proteins must choose which of three -10 region to use. The putative triple 10 region was mutated to make only one of them function with consensus -10 region sequence (TATAAT) and the other two as non-functional region. The results show that the second and third -10 regions are used for the aerobic/anaerobic expression. The third -10 region is responsible for the high aerobic to anaerobic switch ratio. This suggests that only the last two of the putative triple -10 region have functions on aeg-46.5 gene expression switch control. The phenotype of the mutated promoter was tested in the wild type cell and narL - cell. The results indicate that the control by NarL is independent from the selection of -10 region. The expression patterns on multi-copy plasmids and on single-copy chromosome were compared. These results show that the aerobic/anaerobic switch control of aeg-46.5 is through the choice of -10 region. The mechanism of choosing different -10 region remains to be seen.

A buffer readout scheduling for ABR traffic control (ABR 트랙픽 제어를 위한 버퍼 readout 스케쥴링)

  • 구창회;이재호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.25-33
    • /
    • 1997
  • The end-to-end rate-based control mechanism is used for the flow control of the ABR service to allow much more flexibility in ATM switching system. To accommodate the ABR service effciently many algorithms such as EFCI, EPRCA, ERICA, and CAPC2 have been proposed for the switch algorithm. ABR cells and related RM cells are received at the ATM switch fabric transparently without any processing. And then cells received from the traffic source are queued in the ABR buffer of switching system. The ABR buffer usually has some thresholds for easy congestion control signal transmission. Whatever we use, therefore, these can be many ABR traffic control algorithms to implement the ABR transfer capability. The genertion of congestion indicate signal for ABR control algorithms is determined by ABR buffer satus. And ABR buffer status is determined by ABR cells transfer ratio in ATM switch fabrics. In this paper, we presented the functional structures for control of the ABR traffic capability, proposed the readout scheduling, cell slot allocation of output link and the buffer allocation model for effective ABR traffic guranteeing with considering CBR/VBR traffics in ATM switch. Since the proposed readout scheduling scheme can provide more avaliable space to ABR buffer than existing readout scheduling scheme, generation rate of a SEND signal, that is, BCN signal in destination node can be increased for ABR call connection. Therefore, the proposed scheme, in this paper, can be appropriate as algorithm for effective ABR traffic service on output link of ATM switching node.

  • PDF

Computer Generated Hologram for Beam Control of LCOS based Wavelength Selective Switch (LCOS기반의 파장선택스위치 빔제어용 컴퓨터 생성 홀로그램)

  • Lee, Yong-Min;Han, Chang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.744-749
    • /
    • 2016
  • This paper presents the design of a computer-generated hologram for beam control of an LCOS-based wavelength selective switch, which is the core technology for next-generation ROADM. By introducing a computer-generated hologram instead of general grating patterns to control the LCOS device, we contribute to building a more efficient wavelength selective switch. With the use of phase modulation properties of LCOS devices, we designed the hologram for five-port output and a 40-channel wavelength selective switch. We applied a multi-level phase modulation technique with the Gerchberg-Saxton algorithm to produce the hologram, which is easily scalable to any different type of wavelength selective switch. With an experimental setup, we verified the usability of the hologram designed for five-port output. We also suggest a hologram design technique for beam control of a 40-channel wavelength selective switch.

Hybrid LVDC Circuit Breakers (저압직류용 하이브리드 차단기)

  • Hyo-Sung, Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.489-497
    • /
    • 2022
  • This work investigates the commutation characteristics of the current flowing through an electrical-contact-type switch to the semiconductor switch branch during the breaking operation of hybrid DC switchgear. A simple, reliable, low-cost natural commutation method is proposed, and the current commutation characteristics are analyzed in accordance with the conduction voltage drop of the semiconductor switch branch through experiments. A prototype 400 V/10 A class natural commutation type hybrid DC switchgear is set up. Its performance is verified, and its characteristics are analyzed.

An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants (주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가)

  • Byun, Seung-Nam
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF

Implementation of Integration Dimming Switch for Home Network Using Z-Wave Mesh Network (Z-Wave Mesh Network 방식을 이용한 홈네트워크용 통합 디밍스위치의 구현)

  • Hwang, Gi-Hyun;Sul, Jae-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1198-1206
    • /
    • 2011
  • In this paper, we proposed a home network integrated dimmer switch using Z-wave Mesh Network. The dimmer switch come with wired and wireless network-based intelligent lighting switch that can be installed in a apartments with home network technologies. This switch is ease to install and operate. Furthermore, it provide power saving through efficient control of light using motion detect sensor and light intensity sensor. In order to evaluate the performance of our developed home network integrated dimmer switch, we performed a load performance test and from our result, it showed excellent performance in terms of lighting control and communication speed.

A Current Control Algorithm for Torque Ripple Reduction of Four-Switch Three-Phase Brushless DC Motors (4스위치 3상 BLDC 전동기의 토크 리플 저감을 위한 전류제어 알고리즘)

  • 박상현;김태성;이병국;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.126-133
    • /
    • 2004
  • In this paper, a new current control algorithm is proposed for four-switch three-phase brushless DC(BLDC) motor drives, which are suitable for low cost applications. A current reference generation scheme is developed and implemented to obtain high performance characteristics in the four-switch system, such as small torque ripple and fast dynamic speed/torque response. Especially, the proposed scheme can successfully reduce the torque ripple during commutations, so that it can be expected that the four-switch system can be much more practically applied for the industrial application areas.