• Title/Summary/Keyword: sutures

Search Result 355, Processing Time 0.022 seconds

Evaluation of Anastomotic Strength and in-vitro Degradability with Microvascular Anastomosis Coupler Based on Injection Molding Condition made by Biodegradable Polycaprolactone(PCL) (생체분해성 폴리카프로락톤(PCL) 미세혈관 문합커플러의 사출성형조건에 따른 문합강도 및 in-vitro 분해능 평가)

  • Ahn, Geun-Seon;Han, Gig-Bong;Oh, Seung-Hyun;Park, Jong-Woong;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.167-177
    • /
    • 2013
  • The use of mechanical anastomosis coupler instead of sutures has been increasing in microvascular anastomosis surgery. However, non-biodegradable anastomosis coupler has problems such as not only inflammatory reaction but also remaining permanently in operation wound. Therefore, we fabricated biodegradable anastomosis coupler using injection molding process to overcome the limitation of non-biodegradable anastomosis coupler. In various injection molding process conditions, the shrinkage was calculated with different cylinder temperatures and injection molding pressures and anastomotic strength was measured. As a result, changes in shrinkage hole part larger than the pin part. In addition, the shrinkage in the cylinder at higher temperatures increase. However, the higher the injection pressure, shrinkage tends to decrease, respectively. In-vitro degradation behavior of PCL anastomotic coupler evaluated for 12 weeks, water uptake was increased and molecular weight was accompanied by a reduction in mass of the biological degradation and reduction of anastomotic strength was confirmed. However, decreased levels of anastomotic strength enough to exceed the requirements of preclinical surgery, PCL microvascular anastomosis coupler suitable candidate materials that could identify.

A Case of Raine Syndrome (Raine 증후군 1례)

  • Park, Hye Jin;Lee, Jeong Jin;Seo, Jeong Sik;Kim, Hyo Jin;Choi, Je Yong;Lee, Jun Hwa;Nho, Un Seok;Chung, Hai Lee;Kim, Woo Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.91-94
    • /
    • 2003
  • Raine syndrome was described as an unknown syndrome in 1989. It is characterized by severe craniofacial anomalies with microcephaly, hypoplastic nose, depressed nasal bridge, exophthamos/protosis, gum hypertrophy, cleft palate, low-set ears, small mandible, narrow chest, wide cranial sutures and choanal atresia or stenosis, by generalized osteosclerosis with subperiosteal thickening of ribs, clavicles and diaphysis of long bones, and by intracranial calcifications in the particularly periventricular area. It undergoes an autosomal recessive inheritance. Twelve cases of Raine syndrome have been reported in the literature. However, a case of Raine syndrome in Korea has not been reported yet. Therefore, we describe a female newborn with Raine syndrome with a brief review of the literatures.

Formulation of a reference coordinate system of three-dimensional (3D) head & neck images: Part I. Reproducibility of 3D cephalometric landmarks (3차원 두부영상의 기준좌표계 설정을 위한 연구: 1부 CT영상에서 3차원 계측점의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.388-397
    • /
    • 2005
  • The purpose of this study was to redefine the cephalometric landmarks in three-dimensional (3D) images, which are used in orthodontic cephalometric radiography, and to evaluate the reproducibility of each landmark for 3D cephalometric analysis. Eighteen CT scans were taken at the Department of Diagnostic Radiology at Seoul National University Dental Hospital and manipulated with V works 4.0(Cybermed Inc., Seoul, Korea). The coordinate system was established using 7 reference points, with no more than 4 points on the same plane. These 7 points were generated as a volume model, the voxel size of which was 4 by 4 by 2 (threshold value=639). The cephalometric landmarks were selected at the multiplanar reformation (MPR) window on the volume mode of V works 4.0. The selected landmarks were exported to V surgery (Cybermed Inc., Seoul, Korea) for the calculation of coordinate values. All the data were taken twice with a lapse of 2 weeks by one investigator The reproducibility of each landmark was $0.17\~1.21mm$ in the x axis, $0.30\~1.53mm$. In the y axis, and $0.27\~1.81mm$ in the z axis. In all three axes, the range of error was similar. These error ranges were acceptable with regards to the pixel space and slice thickness. The most reproducible points were 1 points which were selected on the basis of the volume model. The least reproducible points were J points that were defined by sutures.

A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

  • Pak, Chang Sik;Chang, Lan Sook;Lee, Hobin;Jeong, Jae Hoon;Jeong, Jinwook;Yoon, Eul-Sik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.572-579
    • /
    • 2015
  • Background Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Methods Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. Results The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Conclusions Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

The Effects of Needle Electrode Electrical Stimulation on Cellular Necrosis Blocking the Hippocampus after Induction of Ischemia (침전극저주파 자극이 해마의 세포사 차단에 미치는 영향)

  • Lee, Jung-Sook;Kim, Byung-Ki;Kim, Sung-Won;Kim, Ji-Sung;Kim, Dong-Il;Song, Chi-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.2
    • /
    • pp.111-120
    • /
    • 2009
  • Objectives : This study was performed to investigate the effects of Needle Electrode Electrical Stimulation (NEES) on ischemia-induced cerebrovascular accidents. After obstruction and reperfusion of ${\ast}{\ast}$ arteries in white mice, the amounts of necrosis and inflammation related substances IL-6, Caspase-3, and PARP, C-fos were measured in neurons of the hippocampus. The following results were obtained. Methods : This study used 21 male specific pathogen free (SPF) SD (Sprague Dawley) rats, 8 weeks of age and approximately 300 g in weight, that were given at least 1 week to adapt to the lab environment Each exposed artery was completely occluded with non-absorbent suture thread and kept in that state for 5 minutes. The sutures were then removed to allow reperfusion of blood. Test group is control group for comparison with the common carotid artery occlusion models, a GI group that underwent common carotid artery occlusion, and a needle electrode electrical stimulation (NEES) group that underwent NEES after artery occlusion. The GI and NEES groups were given 12, 24, or 48 hours of reperfusion before NEES. NEES device (PG6, ITO, Japan, 9V, current, 2Hz) was used to stimulate the right and left acupoint ST36 of the SD rats for 30 minutes while they were sedated with 3% isoflurane. An immunohistochemistry test was done on the forebrains of the GI induced rats. All the data collected from this study was symbolized and analyzed using a statistics processing program (SPSS 12.0K/PC). The level of significance was set at ${\alpha}$=0.05 and a T-TEST analysis was used to find out the effects of treatment on each of the groups: the normal group, the CVA induced group, and the treatment after CVA induction group. Results : Both PARP and C-fos immuno-reactive cells, related to apoptosis, were greater in the GI groups than the NEES group. Caspase and IL-6 immuno-reactive cells, related to inflammation, were greater in the GI and NEES groups than the control group. Conclusions : This research was conducted to study the effects of NEES on CVA due to ischemia. Occlusion and reperfusion was performed on the common carotid arteries of white rats, after which amounts of substances related to neuron necrosis and inflammation - PARP, IL-6, Caspase-3, and C-fos - were measured in the Hippocampus

  • PDF

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Surgical Repair for Ebstein's Anomaly (Ebstein 기형의 수술 -2례 보고-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

흉총창에 의한 심방파열 치험 2례

  • Lee, Doo-Yun;Kwack, Sang-Ryong
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.60-65
    • /
    • 1980
  • We have experienced 2 cases of the hunshot wound sof the chest involving cardiac injuries at department of the thoracic surgery, Capital Armed Forces General Hospital during I year from April I 1979 to Jan. 1980. In one case of two patients , he was a 22 years old man who was transported to this emergency room 4 hour 10 minutes after having gunshot wound of the left chest by helicopter. Physical examination showed small inlet in left 3rd ICS and left parasternal border, large outlet in left 8th ICS and left scapular line, no breath sound on left side and distant heart sound. chest roentgenography demonstrated marked pleural effusion in left side and mediastinum shifted to right. As soon as chest X-ray was taken, the bleeding through penetrating wound became profuse and cardiac arrest ensued. Closed chest cardiac massage was started and vigorous transfusion continued, but no effective cardiac activity could not be obtained. The patient was pronounced dead due to exsanguinating hemorrhage from wuwpected cardiac wounds. In this critically injured patient with evidence of intrathoracic hemorrhage and suspected cardiac penetration, only emergency thoracic exploration and immediate surgical control of bleeding points might offer the maximum possibility of survival. The other case was a 23 years old man who was transferred to the emergency room 4 hours 50 minutes after having kmultiple communicated fractures of sternum and linear fracture of right mandible by a missile. Examination revealed about 30% skin loss of the anterior chest wall, weak pulse of 96 beats/min., distant heart sound and decreased breath sounds bilaterally. finding on the chest X-ray films showed multiple sternal fractures, marked pericardial effusion indicating hemopericardium. So, the patient was moved immediately to the operation room where, after endotracheal tube inserted, a median sternotomy was performced. A hemorrhagic congestion of the right upper lobe and marked bulging pericardium were disclosed. The pericardium was opened anterior to right phrenic nerve and exsanguinating hemorrhage ensued from the 0.5cm lacerated wound in the auricle of right atrium. The rupture site of right atrium was occluded with non-crushing vascular clamps and then was over sewn with interrupted sutures. It was thought to be highly possible that he was alive long enough to have cardiorrhaphy because of cardiac tamponade, which prevented exsanguinating hemorrhage. He was taken closed reduction for linear fracture of right mandible 2 weeks after repair of ruptured right auricle in dental clinic. This patient's post-operative course was not eventful.

  • PDF

Cervical Esophago-Enteric Anastomosis with Straight Endostapler (식도 재건술 시 흉강경용기계문합기을 이용한 경부식-장문합술)

  • Kim, Il-Hyeon;Kim, Kwang-Taik;Park, Sung-Min;Lee, Seung-Yeoll;Baek, Man-Jong;Sun, Kyung;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.924-929
    • /
    • 1999
  • Background: The use of the stapler n esophageal reconstruction after esophageal resection for benign or malignant esophageal diseases has become popular because it has less leakage at the anastomotic site and shorter operation time than manual sutures. However, the use of classic circular stapler has some complications such as stenosis and dysphagia that requires additional treatment. Such complications are closely related to the inner diameter of the anastomotic sites. In this study, the diameter of anastomotic site was compared after the use of circular stapler(EEA) and straight endoscopic stapler(endo GIA). Material and Method: The patients who received esophageal reconstruction by stapler from August 1995 to September 1997 were reviewed. The patients were divided into 2 groups. One group need the circular stapler, and the other group the straight endo GIA(14 cases with endo GIA 30mm, 24 with endo GIA 45mm). After a cervical esophago-enteric anastomosis, the stricture of anastomotic site and the incidence of dysphagia were compared between the 2 groups using an esophagography and the patient's symptoms. The follow-up period was 12months in average. Result: In the former group in which the circular stapler was used, 2 cases of anastomotic stenosis were reported. In comparison, none were reported in the latter group. Dysphagia were reported in 8 cases of the former group, and in 3 cases of the latter group(1 case in endo GIA 30 mm, 2 cases in endo GIA 45 mm). Conclusion: The use of endo GIA in esophago-enteric anastomosis resulted in a wider diameter of the anastomotic site, lesser stricture, and lesser incidence of dysphagia compared to the use of former circular stapler. Therefore, it is thought to be a better method in esophageal reconstructions.

  • PDF

Alternative Technique of Aortic Valve Replacement -Implantation of Mechanical Aortic Valve at a Supra-Annular Level- (기계판막을 판륜상연에 위치시킨 대동맥판 치환술)

  • 최종범;이삼윤
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.504-509
    • /
    • 1996
  • When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.

  • PDF