• Title/Summary/Keyword: suture material

Search Result 103, Processing Time 0.032 seconds

Surgical Removal of the Lung Lobe Metal Foreign Body in a Dog

  • Hwang, Yawon;Kang, Jihoun;Chang, Dongwoo;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.108-111
    • /
    • 2017
  • A 4-year-old, weighing 7.6 kg, castrated male, Pug presented with ingestion of gastric cavity foreign body. Physical examination revealed panting, retching and hyper-salivation. Blood chemistry and complete blood cell count were normal, but hypophosphatemia was observed. An abdominal radiograph revealed the foreign body (FB), round shape and 2 cm length, at the pyloric region of stomach. A thoracic radiograph revealed an incidental metal FB, 3.5 cm length, at the cranial portion of the diaphragm. An upper gastrointestinal endoscopy was performed to remove the FB in the stomach and then a peach-pit was removed. However the metal FB was not found in the esophagus therefore a lateral thoracotomy was performed. A right lateral thoracotomy through the $7^{th}$ intercostal space was accomplished to expose the right caudal lung lobe. After open the thoracic cavity, foreign body was not observed by gross evaluation and caudal lung lobe was attached to the diaphragm. The FB was identified inside the lung lobe and surrounded by granulation tissue. The metal FB (sewing needle) was removed with blunt dissection and incised lung lobe was sutured using absorbable suture material PDS 4-0 with interrupted suture. A thoracotomy tube was inserted into the thoracic cavity during surgery. Patient's respiration became stable after surgery. A chest tube was removed 3 days after surgery. No complications were noted and the dog was discharged 4 days after surgery. In small animal, foreign body ingestion is a common reason for emergency. After ingestion of the FB, perforation through the esophagus and migration to inside the lung lobe is not common in small animals. In this case, thoracic metal FB was identified incidentally and removal of a thoracic FB with thoracotomy was performed successfully.

The effect of suture by absorbable material on corneal astigmatism after phacoemulsification

  • Yoo, Jae Ho;Lee, Sang Joon
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.318-327
    • /
    • 2018
  • Objectives: To investigate the effect of absorbable suture on surgically-induced corneal astigmatism in 3.0-mm sclera tunnel cataract surgeries. Methods: Medical records of patients who underwent phacoemulsification cataract surgery using a 3.0-mm sclera tunnel incision made by a single surgeon were reviewed. Uncorrected distant visual acuity, corneal astigmatism and surgically-induced astigmatism were measured in 56 patients' eyes that underwent sclera tunnel cataract surgery with absorbable sutures (sutured group) and in 23 patients' eyes without sutures (unsutured group). Uncorrected visual acuity, intraocular pressure, slit lamp examination, and automated keratometry were evaluated preoperatively and at 3 days, 2 weeks, 4 weeks, and 8 weeks after cataract operation. Results: There were no significant differences in preoperative average uncorrected distant visual acuity of the two groups (sutured group: $0.79{\pm}0.64$, unsutured group: $0.68{\pm}0.72$, P = 0.145). Corneal astigmatism measured using keratometry in the sutured and unsutured group at postoperative day 3 were $2.27{\pm}2.12D$ versus $0.83{\pm}0.55D$ at (P < 0.001), a difference which had disappeared after 4 weeks. Surgically induced astigmatism using the Holladay and Vector methods showed similar outcomes, suggesting that the sutured group exhibited higher astigmatism compared with the unsutured group until 2 weeks post-surgery. Conclusions: TPatients undergoing scleral tunnel cataract surgery with absorbable sutures have greater surgically induced astigmatism, especially in the early postoperative period, compared with those without sutures. However, this surgically induced astigmatism due to absorbable sutures in scleral tunnel cataract surgery is temporary and disappears at 4 weeks post-surgery.

The Safety and Usefulness of Synthetic Absorbable Monofilament, Glycoside-$\varepsilon$-caprolactonetrimethylene Carbonate Interpolymer, in Gastrointestinal Anastomosis and Closure (위장관문합 및 봉합 시 인공 흡수성 단사인 Glycoside-$\varepsilon$- caprolactone-trimethylene Carbonate 혼성중합체의 안정성 및 유용성)

  • Lee Hyuk-Joon;Kim Yoon Ho;Yang Han-Kwang;Lee Kuhn Uk;Choe Kuk Jin
    • Journal of Gastric Cancer
    • /
    • v.3 no.2
    • /
    • pp.93-96
    • /
    • 2003
  • Purpose: Synthetic absorbable monofilaments offer excellent glide characteristics and cause minimal tissue trauma as a result of their smooth monofilament structure and gradual absorption within the healing tissues. For these reasons, these suture materials are commonly used in various surgical fields such as gastroenterology, urology, gynecology, and plastic surgery. The aim of this study was to evaluate the safety and usefulness of a new synthetic absorbable monofilament, Glycoside-..-caprolactone-trimethylene carbonate interpolymer (GCT), in gastrointestinal anastomosis and closure. Materials and Methods: We evaluated 55 gastrointestinal anastomoses and closures using GCT $MONOSYN^{R}$, B. Braun, Germany) in 47 patients who underwent gastric surgery between December 2001 and May 2002 at Seoul National University Hospital. Patient's characteristics, operative procedure, surgeon's opinion of handling properties of GCT, and suture-related complications were analyzed. Results: There were 34 males and 13 females (M:F= 2.6:1) with an average age of 54.2 years old. Forty-five cases of gastrointestinal anastomosis (20 gastrojejunostomies and 25 jejunojejunostomies) and 10 cases of intestinal closure (7 gastrostomy closures and 3 duodenal stump closures) were performed in 41 cases of stomach cancer, three of peptic ulcer disease, two of GIST, and one MALToma. The handling properties of GCT according to the criteria of knot breaking load, knot security, and placing property were always scored with 7 to 9 points (10=excellent, 1=very poor). Two cases of postoperative complications ($3.6\%$) were noted. One was a leak of the gastrojejunostomy site which was successfully managed conservatively, and the other was a stricture of the gastrojejunostomy site which was managed by reoperation (side-to-side jejunojejunostomy). Conclusion: GCT seems to be an applicable suture material for various gastrointestinal anastomoses and closures.

  • PDF

Factors Affecting Patency Rate in Microvascular Anastomosis of the Femoral Artery in Rat (쥐 대퇴 동맥의 미세 문합시 개존성에 영향을 미치는 인자)

  • Lee, Jun-Mo;Seo, Kyu-Bum
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.1
    • /
    • pp.63-66
    • /
    • 2002
  • Microvascular anastomosis is too important to reduce the failure in operating room because of no choice in case of failure and prognosis of the failure would be more worse than any other success ones. Factors for microsurgery trainee influencing patency in microvascular anastomosis at the laboratory are numerous but three basic prerequisites are magnification, instruments and suture material and training. First Author trained microsurgical technique to the second author using femoral artery of the rat and patency of the anastomosis was evaluated by the milking test. Period which microsurgeon successes femoral arterial anastomosis in rat in both of 5 and 30 minutes was 7th week at the laboratory which has done 2 vessels a week under the supervise of the skilled first author.

  • PDF

Degumming of Antheraea yamamai silkworm cocoon

  • Shin, Bong-Seob;Jeon, Jong-Young;Kim, Jong-Ho
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.31 no.2
    • /
    • pp.127-131
    • /
    • 2015
  • Oak silkworm, Antheraea yamamai (A. yamamai), has been used for clothing and surgical suture and considered as biomaterial due to RGD tripeptide. This paper reported the degumming conditions of A. yamamai using sodium oleate, high pressure and temperature, and sodium carbonate. Degumming ratio of A. yamamai cocoon using sodium oleate was less than 10%. High pressure and temperature treatment induced 30% weight loss of A. yamamai cocoon. The concentration, treatment temperature and time using sodium carbonate was examined and revealed the following conditions for degumming; 5% owf, 60 min at 100℃. The degummed solution was confirmed using UV and FT-IR spectrometer. Our results can be used to handle A. yamamai silkworm cocoon for further application including material processing.

Training of Microanastomosis with Chicken Wing Brachial Artery (닭 날개 혈관을 이용한 혈관문합술의 교육)

  • Kwon, Soon Sung;Jeong, Jae Hoon;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.274-277
    • /
    • 2007
  • Purpose: Microsuturing is a difficult job for beginners of microsurgery. It is because they are not familiar with microscopic environment and, it needs much time for them to get used to microanastomosis. Before the real microsurgery, sometimes a surgeon wants rehearsal. But, microsurgical exercise has been performed with surgical glove, silastic drain or rat femoral artery. Rat femoral artery is a very good training material. But, it needs animal laboratory, anesthesia and its keeping facilities. And the surgeon should appoint the time to exercise with the laboratory. Methods: We used chicken wing brachial artery for education material of microsuturing. The artery is 5 cm long and the diameter is about 1 mm. Monofilament 10-0 was used for suture material. Results: Six persons of Seoul National University medical school students and one resident attended in this program. Each of them performed arterial anastomosis ten times. They were satisfied with chicken wing brachial artery for anastomosis training under the magnification environment. Conclusion: We think that chicken wing brachial artery is a very cheap and an effective training material for the beginners of microsurgery.

Firing Conditions and Material Characteristics of Neolithic Potteries from the Goseong Munamri Sites, Korea (고성 문암리 출토 신석기 토기의 재질특성과 소성조건)

  • Kim, Su Kyoung;Jang, Sungyoon;Lee, Chan Hee
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.197-212
    • /
    • 2020
  • This study was carried out material characteristics and firing conditions for some potteries in early and middle Neolithic period at the Munamri sites, where the first farmland remails were found in Korea. It is divided into six kinds of surface patterns for potteries such as the raised, bamboo tube and red painted (patternless) from the early Neolithic period (BC 4000 to 6000), and the patterns of horizontal herringbone, short slanted lined or lattice and incised thick line in the middle Neolithic period (BC 3000 to 4000), respectively. Based on the color measures, redness and yellowness of potteries were relatively high as condition of oxidation firings, were also observed black cores on the cross section of potteries. The firing temperature is divided into two groups having under 800℃ and 800to 900℃, the difference in patterns of the potteries are not confirmed. As a microtextures, the bamboo tube pattern potteries show the sericitization biotite, the quartz have developed a suture line textures, and altered alkali feldspars are occurred. X-ray diffraction analysis shows that the main minerals contained in potteries are chlorite and amphibole besides quartz, alkali feldspar and biotite. Considering the geology around the Munamri area is the biotite amphibole granite and soil layers within 10km radius are used as the raw materials for the potteries. The raw materials are presumed that the sources from the metamorphic rocks along the water systems through the mountains around the sites on the basis of well developed suture line textured quartz in potteries. Results on normalized geochemical compositions, the potteries by surface patterns are very similar to sources, and it is judged that was made by using the surrounding soils despite the long time difference from the early to middle in the Neolithic period.

Histological comparison of different compressive forces on particulate grafts during alveolar ridge preservation: a prospective proof-of-concept study

  • Lee, Sung-Jo;Kang, Dae-Young;Cho, In-Woo;Shin, Hyun-Seung;Shin, Seung-Il;Fischer, Kai R.;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.3
    • /
    • pp.197-206
    • /
    • 2020
  • Purpose: The aim of this study was to determine the impact of different compressive forces on deproteinized bovine bone mineral (DBBM) particles covered by native bilayer collagen membrane (NBCM) during alveolar ridge preservation (ARP) in the molar area, and to identify any histomorphometric and clinical differences according to the compressive force applied. Methods: Sockets were filled with DBBM after tooth extraction, and different compressive forces (30 N and 5 N, respectively) were applied to the graft material in the test (30 N) and control (5 N) groups. The DBBM in both groups was covered with NBCM in a double-layered fashion. A crossed horizontal mattress suture (hidden X) was then made. A core biopsy was performed using a trephine bur without flap elevation at the implant placement site for histomorphometric evaluations after 4 months. The change of the marginal bone level was measured using radiography. Results: Twelve patients completed the study. The histomorphometric analysis demonstrated that the mean ratios of the areas of new bone, residual graft material, and soft tissue and the implant stability quotient did not differ significantly between the groups (P>0.05). However, the mean size of the residual graft material showed a significant intergroup difference (P<0.05). Conclusions: The application of 2 compressive forces (5 N, 30 N) on particulate DBBM grafts during open-healing ARP in the posterior area led to comparable new bone formation, implant feasibility and peri-implant bone level.

Reduction Aortoplasty with Suture Plication Technique for Dilatation of the Ascending Aorta associated with Aortic Valve Disease (대동맥판막 질환과 동반된 상행대동맥 확장에 대한 봉합봉축법에 의한 대동맥 축소성형술)

  • Na Chan-Young;Oh Sam-Sae;Lee Chang-Ha;Whang Seong Wook;Lee Cheol;Lim Hong Gook;Kim Jae Hyun;Seo Hong Ju;Kim Gun Gyk;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.221-228
    • /
    • 2005
  • Reduction aortoplasty has been advocated for dilatation of the ascending aorta associated with aortic valve disease in older, high-risk patients. We report our results with modification of reduction aortoplasty and aortic valve replacement. Material and Method: Between July 2001 and December 2002, 14 consecutive patients who underwent modification of reduction aortoplasty, suture plication technique without excision of the dilated aortic wall, were reviewed. The mean age was 63.7$\pm$6.7 (50 to 75) years. Ten patients had congenital bicuspid aortic valve, Twelve patients had severe aortic valve stenosis and 6 had regurgitation of grade III$\~$IV. The diameter of the ascending aorta was measured before and immediately after surgery and 6 and 12 months postoperatively using echocardiography or computed tomography. Follow-up was complete in an average of 14.7$\~$5.4 (7 to 24) months. Result: There were no early postoperative deaths and no bleeding complications. Reduction aortoplasty with suture plication technique decreased the diameter of ascending aorta from 49.4$\pm$3.5 mm preoperatively to 33.2$\pm$3.4 mm postoperatively (p <0.001). During follow-up, there were no late deaths and no aneurysm recurrence on the ascending aorta. Conclusion: Suture plication technique of reduction aortoplasty without excision of the dilated aortic wall offers good early and short-term results in older, high-risk patients with dilatation of the ascending aorta associated with aortic valve disease. Surgical long-term results of our technique should be evaluated in further studies.

Uptake of Fibroin Microspheres by 3T3 Cells (3T3 세포에 의한 피브로인 마이크로스피어의 흡수)

  • Lee, Jin Sil;Go, Nam Kyung;Lee, Shin Young;Hur, Won
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Vehicle toxicity is one of the main obstacles for intracellular delivery of bioactive compounds. Silk fibroin is a natural polymer proven to have high biocompatibility since being used as suture material. In this report, fibroin microspheres were prepared without any chemical modification or cross-linking not to affect its biocompatibility. The microspheres were taken up by more than 90% of 3T3 cells. Cellular uptake continued after medium replenishment with a different-colored fluorescent microsphere, suggesting that simultaneous ingestion and exocytosis occurred. Cellular uptake of fibroin microspheres did not affect cell viability. Intracellular trafficking of the microspheres using lysosome-specific fluorescent dye revealed that fibroin microspheres were localized both in the cytoplasm and in the lysosome. Accordingly, fibroin microspheres can be a potential vehicle for intracytoplasmic delivery of large cargos, such as mixtures of proteins, nutrients or artificial organelles.