A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

Transaortic Mitral Commissuroplasty with a Bentall Procedure or Artic Valve Replacement (대동맥 판막 치환술과 벤탈 수술 환자에서 대동맥 근부를 통한 승모판막 교련 성형술)

  • Kim, Si-Wook;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.727-732
    • /
    • 2007
  • Background: The reciptents of aortic valve replacement or a Bentall operation usually display various degrees of mitral regurgitation. When deciding whether or not to correct the mitral regurgitation, one must consider its severity, underlying causes and operative risk. Recently, the operation method for correcting the concomitant mitral regurgitation has been done through aortic root to reduce the operation time and the cardiac trauma. We report our experiences that transaortic mitral valve commissuroplasty done with aortic valve replacement or a Bentall operation has been a simple, less invasive, effective method in the operative management of mitral valve regurgitation without significant organic changes. Material and Method: Between June 2002 and June 2005, twenty patients under-went mitral valve commissuroplasty via the aortic root with aortic valve replacement (n=14) or a Bentall operation (n=7). The mitral valve regurgitation of the patients didn't exceed a moderate (grade 2) degree and there was no significant organic disease. The preoperative diagnosis of MR was established by TTE and intraoperative TEE, and the patients were followed postoperatively by TTE. The operative technique was a simple anterolateral commissuroplasty of the mitral valve with a single mattress suture via the transaortic annular approach after excision of the aortic valve leaflets. Result: The mean patient age was 56.2 years and 65% (n=13) were male. The preoperative MR was mild (grade 1) in 9 (45%), mild to moderate in 8 (40%), and moderate (grade 2) in 3 (15%) patients. There were no operative mortalities. The MR improved in all patients (p=0.002) and the left ventricular ejection fraction (LV EF) improved in 14 (70%) patients (p=0.005). The mean cross-clamp time for the patients who under- went aortic valve replacement with transaortic mitral repair was $62.1{\pm}13.9 min$ and this was $137.5{\pm}7.2 min$ for the patients who underwent a Bentall operation with transaortic mitral repair. Conclusion: For selected patients without significant mitral organic disease, transaortic mitral valve commissuroplasty combined with aortic valve replacement or a Bentall operation may be a feasible, effective method without adding significant aortic cross clamping time and more cardiotomy.

A STUDY ON PROFILE CHANGE OF SKELETAL CLASS III MALOCCLUSION PATIENTS AFTER WEARING PROTRACTION HEAD GEAR (골격성 제III급 부정교합 환자에서 상악골 전방견인장치 사용후 측모 변화에 대한 연구)

  • Lim, Joong-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.375-401
    • /
    • 1995
  • Cause of skeletal Class III malocclusion in growing patients can be classified into maxillary deficiency, mandibular overgrowth, and combination of the two. Use of Protraction Head Gear(P.H.G.) has been recommended for treatment of growing Class III malocclusion patients, for it results in forward & downward movement of maxilla and backward & downward rotation of mandible. Numerous animal experiments were performed and clinical study data have been reported ; nevertheless, studies on soft tissue profile change and comparison of treatment effects among the patients who had undergone treatment are considered to be somewhat insufficient. The author selected 93 patients, who had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with P.H.G. ; the sample group was divided according to sex, treatment beginning age, palatal suture opening(intraoral appliance), and facial growth pattern. For each group, changing patterns of hard and soft tissue profile observed, and comparision with 20 normal group(Angle's Class I) patients of statistical significance in amount of growth and treatment of hard and soft tissue was done. The following results were obtained. 1. Skeletal, dental, and soft tissue measurements indicated that more growth changes was induced in the sample group that used P.H.G. compared to the growth amount of normal group. 2. No statistical significance was observed in the amounts of maxillary forward movement and mandibular backward & downward rotation depending on treatment beginning age in both sex group. 3. R.P.E. showed more significant maxillary forward movement and less protrusion of upper incisor than La-Li. 4. There was no statistical significance in the amount of maxillary forward movement depending on facial growth pattern. On the other hand, measurements indicating mandibular downward & backward rotation indicated greater change in counterclockwise growth pattern group than the clockwise. 5. Changes in upper and lower lip thicknesses showed a close relationship with positional changes in underlying bone tissue and upper and lower teeth, and upper lip height and nasolabial angle increased and mentolabial angle decreased.

  • PDF

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF

Arthroscopic Decompression of Spinoglenoid Ganglion Cyst (견갑골 극관절와 결절종의 관절경하 감압술)

  • Hwang, Tae Hyok;Wang, Tae Hyun;Cho, Hyung Lae;Kim, Keun Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • Purpose: We describe a all-arthroscopic technique for decompression of spinoglenoid ganglion cyst and present our clinical results for this procedure. Materials and Methods: From March 2006 to June 2009, eight patients (7 males, 1 female; mean age 40.6 years; range: 21~61) were included who underwent arthroscopic decompression of spinoglenoid ganglion cyst. The most common symptoms were vague shoulder pain and external rotation weakness, which lasted 6.4 months (range: 3~8) on average. Five of eight patients were noted abnormalities on electromyographic (EMG) examination to have suprascapular nerve neuropathy and magnetic resonance imaging (MRI) showed spinoglenoid ganglion cysts in all eight patients and the cyst size was 2.6 cm (range: 1.8~3.6). Labral pathology was identified intraoperatively in all patients and the cysts were decompressed by the posterosuperior capsulotomy under arthroscopic control and labral repair with suture anchors was performed in six patients. Results: The average clinical outcome scores including Constant and Murley, Simple shoulder test (SST) all improved significantly at the time of the final follow-up and there were no complications resulting from the procedures. All patients including the patients with abnormal EMG study recovered strength on isokinetic strength testing. Follow-up MRI scans were performed on all patients at a mean of 5.2 months postoperatively (range: 3~12) revealed complete resolution of the cysts and no evidence of recurrences were seen at an average of 18 months (range: 12~26) of follow-up. Conclusion: Arthroscopic decompression of spinoglenoid ganglion cyst effectively restores patient function and all patients in this study showed improvement in their postoperative MRI findings. Arthroscopic decompression is also useful in the appropriate treatment for labral pathology and may contribute to decreased risk of cyst recurrence.

  • PDF

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Mid-term Results of the Congenital Bicuspid Aortic Valve Repair (선천성 이엽성 대동맥판막질환에 대한 판막성형술의 중기 성적)

  • 조광리;곽재건;안혁
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.833-838
    • /
    • 2004
  • Background: Despite the excellent early results after the repair of congenital bicuspid aortic valve (BAV) disease, the mid-term durability of the repaired valve has still controversies. Material and Method: To evaluate the mid-term results of BAV repair, retrospective review of medical records and echocardiographic data were done. Between 1994 and 2003, twenty-two patients underwent reparative procedure for either regurgitant or stenotic congenital bicuspid aortic valve (BAV). Result: Mean age was $41\pm14$ years with male predominance (Male=17, Female=5). The pathophysiologies of the BAV were regurgitation-dominant in 20 (91%) and stenosis-dominant in 2 (9%) cases. Various repair techniques were used for raphe, prolapsed leaflet, thickened leaflet, and commissures; 1) release of raphe in 19 (86%), 2) wedge resection and primary repair in 11 (50%), pericardial patch reinforcement after plication of the leaflet in 6 (27%), and plication of the leaflet in 3 (14%), 3) slicing of thickened leaflet was used in 12 (55%) cases, 4) commissuroplasty in 8 (36%), and commissurotomy in 6 (27%) cases. There was no in-hospital mortality. During the mean follow-up of $38\pm17$ months, one patient underwent aortic valve replacement after developing acute severe regurgitation from dehiscence of the suture on postoperative 2 months. New York Heart Association functional class was improved from $1.9\pm0.6$ to $1.2\pm0.5$ (p<0.01). Left ventricular end-systolic and diastolic dimension (LVESD/LVEDD) were also improved from $45\pm9$ and $67\pm10$ to $37\pm10$ and $56\pm10,$ respectively (p<0.01). The grade of aortic regurgitation (AR) was improved from preoperative $(3.1\pm1.2)$ to post-bypass $(0.9\pm0.7).$ However, the grade at last follow-up $(1.7\pm1.1)$ was deteriorated during the follow-up period (p<0.01). Freedom from grade III and more AR at one, three, and four year were 89.7%, 89.7%, and 39.9% respectively. Conclusion: Midterm clinical result of the BAV repair was favorable. But, the durability of the repaired valve was not satisfactory.

Bivalvation Valvuloplasty for Common Atrioventricular Valve Regurgitation in Functional Single Ventricle; Early and Mid-term Results (기능적 단심설에서 공통방실판 역류의 판막성형술; 판막 이분성형술(bivalvation)의 조기 및 중기 결과)

  • Chang, Yun-Hee;Sung, Si-Chan;Kim, Seon-Hee;Lee, Hyoung-Doo;Ban, Ji-Eun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.597-603
    • /
    • 2009
  • Background: Atrioventricular valve regurgitation in pediatric patients with a functional single ventricles (FSV) - has been known as one of the important risk factors for death and unfavorable long-term results after a Fontan operation. We evaluated early and mid-term results of bivalvation valvuloplasty in FSV patients. Material and Method: We retrospectively evaluated 11 patients with a functional single ventricle who underwent bivalvationvalvuloplasty between 1999 and 2007. The degree of common atrioventricular valve regurgitation (CAVVR) was determined by color Doppler echocardiography (regurgitation grade scoring, trivial; 1, mild; 2, moderate; 3, severe; 4). Mean age at valve surgery was $6.9{\pm}7.0$ months (median 4 months, 24 days$\sim$21 months)and mean body weight was $6.2{\pm}2.8\;kg$ ($3.1{\sim}11.3\;kg$). Nine patients had isomerism heart and two of them had TAPVC. The concomitant procedures were performed in all but one patient. Additional commissural closure was performed in 3 patients and commissural annuloplasty in another 3 patients. Result: There was one hospital death after. surgery. A 32-day old patient who had been preoperatively dependent on a ventilator died of air way and lung problems 4.3 months after pulmonary artery banding and bivalvation valvuloplasty. Mean follow-up duration was 40 months ($4.3{\sim}114$ months). Mean preoperative CAVVR score was $3.3{\pm}0.6$, which decreased to $1.9{\pm}0.7$ postoperatively (p<0.0001). This residual regurgitation slightly increased to $2.2{\pm}0.4$ (no statistical significance) after a mean follow-up of 1.4.3 months. Six patients (60%) required re-operations for residual regurgitation at a subsequent bidirectionalcavopulmonary shunt or Fontan operation. One patient with Ebsteinoid malformation of the right sided atrioventricular valve required valve replacement due to stenoinsufficiency. Another patient required edge-to-edge repair at the right sided AV valve (between the right mural leaflet and the bridging leaflets). The remaining 4 patients required additional suture placements between bridging leaflets with or without commissural annuloplasty. All survivor had trivial or mild CAVVR at the latest follow-up. Conclusion: Bivalvation valvuloplasty for CAVVR in FSV patients is. an effective and safe procedure. However, significant numbers of the patients have small residual regurgitation and require additional valve procedures at subsequent operations. Long-term observations to monitor progression of the CAVVR is mandatory.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF