• Title/Summary/Keyword: suture

Search Result 1,070, Processing Time 0.034 seconds

Fixation with Suture Material in Akin Osteotomy (봉합사 고정을 이용한 Akin 절골술)

  • Young, Ki-Won;Lee, Kyung-Tai;Kim, Jae-Young;Cha, Seung-Do;Kim, Eung-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.138-141
    • /
    • 2004
  • Purpose: The purpose of this study was to document the results of fixation with ethibond suture in akin osteotomy and its advantages. Materials and Methods: From May 2001 to January 2004, Akin osteotomy was performed in 218 patients. We reviewed 110 patients (114 feet) who were possible radiographic evaluation more than 6 months after operation. 110 feet had hallux valgus and 4 feet had hallux valgus interphalangeus. 105 patients were female and 5 were male. The average age was 43.8 years old (18 to 68 years old). The average follow up was 9 months (6 to 23 months). After performing the Akin osteotomy at 7 mm from the proximal articular surface of the proximal phalanx, one hole is made on either side of the osteotomy site with a K-wire. The passer was passed through the both holes and the ethibond was passed. And then, the ethibond was tied tightly. 2 sutures in 66 feet and 1 suture in 48 feet were made. Radiographic bone union at 6 months follow up was regarded as success and loss of the reduction, nonunion was regarded as failed. Results: In the radiographic evaluation, bony union were made at 6 months follow up in all feet. There was no difference between 2 sutures and 1 suture, and the knots were removed in 3 feet because of skin irritation. Conclusion: The fixation of the osteotomy site using suture material was an effective method in Akin osteotomy. The advantage of this procedure was unnecessity of the material removal.

  • PDF

Fixation with Absorbable Suture Material in Akin Osteotomy (흡수성 봉합사를 이용한 무지외반증 Akin 절골술)

  • Song, Moo-Ho;Kim, Bu-Hwan;Ahn, Seong-Jun;Yoo, Seong-Ho;Lee, Doo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.149-152
    • /
    • 2011
  • Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also, any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.

A STUDY OF THE SUTURAL FACIAL BONE GROWTH OF RABBIT : SERIAL ROENTGENOGRAPHIC STUDY BY MEANS OF MEANS OF IMPLANTS (금속매식법(金屬埋植法)에 의(依)한 가토(家兎)의 봉합성(縫合性) 안면골성장(顔面骨成長)에 관(關)한 X-선학적(線學的) 연구(硏究))

  • Lee, Won Chul
    • The korean journal of orthodontics
    • /
    • v.9 no.1
    • /
    • pp.23-35
    • /
    • 1979
  • The present study has the purpose of investigating various growth and developmental aspects of rabbit snout with the aid of metallic implantation and of improving on the indirect method of growth and developmental studies of its skull. Sixty-eight growing albino rabbits were used. A head holder, film holder, cephalometer, metallic implanting device and implant materials were designed and constructed by the author. Eight metallic pins were implanted with a metallic implanting device in the rabbit snout under general anesthesia. Two metallic pins were implanted on each side of the interfrontal suture and another two were put on each side of the internasal suture near the frontonasal suture. Serial cephalograms were taken with a two-week interval, using the head holder, film holder and cephalometer. Eight items of linear measurement were obtained from the film. On the base of the results of the study, the following conclusions are obtained: 1. The metallic implant method is better than the other indirect methods for growth and developmental studies of the rabbit skull. 2. Most of the vertical growth of the rabbit snout is due to sutural growth at the frontonasal suture and the horizontal growth is at the interfrontal and the internasal suture. 3. The vertical growth of the rabbit snout is greater than the horizontal growth. 4. The horizontal growth of the rabbit snout is greater at the nasal bone than at the frontal bone. 5. The amount of vertical growth of the rabbit snout is almost same at inner and outer side of the interfrontal and internasal suture line, 6. Growth rate of the sutural growth of the rabbit snout tends to decrease by the growth of the rabbit. 7. Implant materials do not disturb growth and development of the rabbit snout, except a slight trauma effect during the first week of metallic implantation.

  • PDF

The Correction of Inverted Nipple Using Modified Purse-string Suture (변형된 쌈지봉합을 이용한 함몰 유두의 교정)

  • Oh, Sang-Ha;Woo, Jong Seol;Lee, Seung Ryul;Kim, Jae Ryoung
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.687-691
    • /
    • 2008
  • Purpose: An inverted nipple presents both cosmetic and functional problems. It is a source of repeated irritation and inflammation, and interferes with nursing. In addition, its abnormal appearance may cause psychological distress. With consideration of its underlying pathophysiologic components and severity, a number of techniques have been introduced for correction of this anomaly. The diversity of techniques indicates the lack of a good, sustainable, and durable solution for this quite common problem. We report our method as an alternative solution for correcting of the inverted nipple. Methods: From August 2003 to November 2007, 273 nipples in 147 patients were treated. 126 patients had bilateral inverted nipples. Patient age at the operation ranged from 21 to 63 years(mean age, 34 years). All nipples were congenital anomaly. 45 nipples were graded as grade I, 179 nipples as II, and 49 nipples as III. In the our study, we made some modification to the classic purse-string suture: (1) twice purse-string suture: (2) excision of diamond-shaped skin at the nipple neck: (3) buried suture of the breast parenchyma at the nipple base: (4) some timely release of retraction using Bovie's electrocautery dissection at inner surface of the nipple neck. Results: The operation time averaged 15 minutes. The mean follow-up period ranged from 3 to 48 months, with an average of 8.4 months. There were no complications associated with the surgery, such as infection, hematoma, permanent sensory disturbance, or total nipple necrosis except temporary sensory loss in 9 cases, partial nipple necrosis in 7 cases, and recurred inversion in 15 cases. All patients except recurred inversion were satisfied with their results. Conclusion: We believe that our modified purse-string suture is a reliable, simple, safe, and effective method for correcting the inverted nipple.

Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion (Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료)

  • Kim, Jae Won;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

Modified Suturing Techniques in Carotid Endarterectomy for Reducing the Cerebral Ischemic Time

  • Joo, Sung-Pil;Cho, Yong-Hwan;Lee, Yong-Jun;Kim, You-Sub;Kim, Tae-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.834-840
    • /
    • 2020
  • Objective : Carotid endarterectomy (CEA) is an effective surgical procedure for treating symptomatic or asymptomatic patients with carotid stenosis. Many neurosurgeons use a shunt to reduce perioperative ischemic complications. However, the use of shunting is still controversial, and the shunt procedure can cause several complications. In our institution, we used two types of modified arteriotomy suture techniques instead of using a shunt. Methods : In technique 1, to prevent ischemic complications, we sutured a third of the arteriotomy site from both ends after removing the plaque. Afterward, the unsutured middle third was isolated from the arterial lumen by placing a curved Satinsky clamp. And then, we opened all the clamped carotid arteries before finishing the suture. In technique 2, we sutured the arteriotomy site at the common carotid artery (CCA). We then placed a curved Satinsky clamp crossing from the sutured site to the carotid bifurcation, isolating the unsutured site at the internal carotid artery (ICA). After placing the Satinsky clamp, the CCA and external carotid artery (ECA) were opened to allow blood flow from CCA to ECA. By opening the ECA, ECA collateral flow via ECA-ICA anastomoses could help to reduce cerebral ischemia. Results : The modified suture methods can reduce the cerebral ischemia directly (technique 1) or via using collaterals (technique 2). The modified arteriotomy suture techniques are simple, safe, and applicable to almost all cases of CEA. Conclusion : Two modified arteriotomy suture techniques could reduce perioperative ischemic complications by reducing the cerebral ischemic time.

Arthroscopic All-Inside Repair of Medial Meniscus Root Tear Using 18 Gauge Spinal Needle and Suture Anchor -A Report of Surgical Technique- (18 Gauge 척수 주사 바늘과 Suture Anchor를 이용한 내측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술 술기 보고 -)

  • Kim, Jong-Min;Jung, Sung-Hoon;Lee, Sang-Ho;Park, Byeong-Mun;Lee, Kil-Hyeong;Jeon, Ho-Seung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.1
    • /
    • pp.66-71
    • /
    • 2012
  • The posterior root of medial meniscus maintains normal meniscal function by circumferential hoop tension and prevents extrusion of meniscus and progression of osteoarthritis. A complete tear of posterior root of medial meniscus leads to loss of hoop tension, it is important to repair it and preserve the function of the medial meniscus. Recently, a variety of arthroscopic assisted reduction and repair techniques have been used. We create an arthroscopic all-inside suture technique using a 18 gauge spinal needle and suture anchor that is easier and more convenient compared with the previous techniques. So we report this technique with a review of current literatures.

  • PDF

Treatment of Acute Achilles Tendon Rupture Using Krackow Suture Technique (Krackow 봉합술을 이용한 아킬레스 건 급성 파열의 치료)

  • Kim, Hyong-Nyun;Park, Ki-Hoon;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2009
  • Purpose: We try to evaluate the clinical results of the acute Achilles tendon rupture treated with Krackow suture technique. Materials and Methods: We reviewed 27 patients with acute Achilles tendon rupture treated between October 2005 and September 2007. There were 26 complete ruptures and 1 incomplete rupture. All were ruptured at tendinous area. There were 21 men and 6 women, and mean age was 38 years. We repaired ruptured Achilles tendon with Krackow suture technique. The results were evaluated with Arner-Lindholm scale for patients' satisfaction, strength of calf muscle power, calf circumference, and ankle motion. The average follow-up was 29 months. Results: The patients' subjective clinical results was excellent in 25 cases and good in 2 cases. There were 15 cases of less than 1 cm, 6 cases of 1${\sim}$3 cm, and 1 case of more than 3 cm in the calf circumference difference between the normal and affected leg. There were 20 cases of less than 5 degrees, and 2 cases of more 5 degrees in the difference of range of motion between the normal and affected ankle. We had an experience of postoperative deep infection in one diabetic patient. Conclusion: We had a good clinical result for acute Achilles tendon rupture treated with Krackow suture method. So we recommand Krackow suture technique for acute Achilles tendon rupture.

  • PDF

Surgical Treatment of Ahilles Tendon Rupture Using Modified Lynn Method (변형 Lynn씨 방법에 의한 아킬레스건 파열의 수술적 치료)

  • Kang, Jae-Do;Kim, Kwang-Yul;Kim, Hyung-Chun;Kim, Jin-Hyung;Choi, Shin-Kwon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.223-231
    • /
    • 2003
  • Purpose: Achilles tendon rupture has become more common in the recent years. As suture with foreign material has been blamed for impaired healing, better results should be expected from the use of autogenous material such as plantaris tendon. We have evaluated the surgical results of end-to-end anastomosis using the plantaris tendon as suture material. Materials and Methods: Between Jan 1997 and Jan 2002, the 60 patients were included this study during one year follow-up. We performed the operations with end-to-end suture technique using modified Lynn's method. The plantaris tendon has been used as a autogenous suture material and can be utilized in the end-to-end anastomosis of ruptured Achilles tendon with modifed Bunnel suture technique. We used a clinical scoring system reported by Leppilahti to evaluate the results. Results: The overall results were excellent in thirty eight(63.3%), good in sixteen(26.6%), fair in five(8.3%) cases, and poor in only one (1.6%) case. Fifty four cases(90%) had the score more than good. We had no deep infection, rerupture, deep vein thrombosis, and skin necrosis as major complication. In just 2 cases, although there were superficial skin infection, the wounds did not proceed necrosis due to using antibiotics. Conclusion: End-to-end anastomosis using the plantaris tendon as suture material was good treatment option that had low infection rate and no foreign body reaction because of using autogenous material, and therefore we can get rapid healing of ruptured tendon due to early ragne of motion and accerlerated rehabilitation.

  • PDF

Short-Term Results of a Modified Kidner Procedure Using a Suture Bridge Technique for Symptomatic Type II Accessory Navicular (증상을 동반한 제 2형 부주상골에서 교량형 봉합술을 이용한 변형 Kidner 술식의 단기 치료 결과)

  • Kim, Eungsoo;Moon, Jinseon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.2
    • /
    • pp.73-77
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the clinical outcome of a modified Kidner procedure using a suture bridge technique in symptomatic type II accessory navicular. Materials and Methods: Between January 2013 and December 2014, a total of 35 cases with symptomatic type II accessory navicular were treated with a modified Kidner procedure using the suture bridge technique. The patients were evaluated preoperatively, 3 months after surgery, and at the latest follow-up (at least six months postoperatively) clinically via the American Orthopaedic Foot and Ankle Society (AOFAS) midfoot score, visual analogue scale (VAS), and the self-subjective satisfaction score. Results: The mean AOFAS midfoot score demonstrated significant improvement from a mean of 45.3 preoperatively to a mean of 89.2 at 3 months after surgery. At the latest follow-up, the mean AOFAS midfoot score was 92.6 (p<0.001). The mean VAS also improved significantly, decreasing from 6.7 out of 10 preoperatively to 1.8 at 3 months after surgery. At the latest follow-up, the VAS was 1.2 (p<0.001). The mean time of a single-limb heel raise was 4.6 months postoperatively and the self-subjective satisfaction score was 1.4 out of 4 at the latest follow-up. Conclusion: The short-term surgical results of the modified Kidner procedure with a suture bridge technique for symptomatic type II accessory navicular were good to excellent in terms of pain, functional and clinical assessments. In conclusion, the modified Kidner procedure with the suture bridge technique is a reasonable treatment option for symptomatic type II accessory navicular.