• Title/Summary/Keyword: surface-treated implant

Search Result 198, Processing Time 0.025 seconds

Prospective Clinical Trial of Survival Rate for Two Different Implant Surfaces Using the Osstem(R) SS II Non-submerged Implant System in Partially Edentulous Patients

  • Kim, Su-Gwan;Lim, Chae-Su;Oh, Min-Seok;Park, Jin-Sung;Kim, Seo-Yoon;Seol, Ka-Young
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.35-41
    • /
    • 2009
  • Objective : This study sought to investigate the clinical survival rate of two implants with different surfaces: resorbable blasting media (RBM)-treated and calcium metaphosphate (CMP)-coated implant. Study design : SSII non-submerged implants (Osstem, Seoul, Korea) were placed in a total of 48 patients with mean age of 38.8. At least 31 patients in the experimental group had a CMP-coated implant, and 1 patient in the control group received a, RBM surface implant. The evaluation period was between April 2006 and December 2007. Radiographs, periotest, clinical periodontal examination, and prosthetic adjustment and occlusion were used. Results : The survival rate of the experimental and control groups after 1 year was 97.2% and 100%, respectively. The Wald confidence interval reported for the experimental group was not inferior to the control group. Conclusion : No significant differences were found between the RBM and CMP groups. The observed data suggest that CMP-coated methods can provide favorable clinical results for the functioning and healing of dental implants.

  • PDF

Evaluation on the efficacy and safety of calcium metaphosphate coated fixture

  • Cho, In-Ho;Lee, Jae-Hoon;Song, Young-Gyun;Kim, Young-Mi;Jeon, So-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.172-178
    • /
    • 2013
  • PURPOSE. The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS. This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS. In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION. One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.

Hydrothermal Synthesis of $TiO_2$ Nanowire Array for Osteoblast Adhesion

  • Yun, Young-Sik;Kang, Eun-Hye;Hong, Min-Eui;Yun, In-Sik;Kim, Yong-Oock;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.275-275
    • /
    • 2013
  • Osteoblast is one of cells related with osseointegration and many research have conducted the adhesion of osteoblast onto the surface of implant. In the osseointegration, biocompatibility of the implant and cell adhesion to the surface are important factors. The researches related to cell adhesion have a direction from micro-scaled surface roughness to nano-scaled surface roughness with advancing nanotechnology. A cell reacts and sense to stimuli from extracellular matrix (ECM) and topography of the ECM [1]. Thus, for better osseointegration, we should provide an environment similar to ECM. In this study, we synthesize TiO2 nanowires using hydrothermal reaction because TiO2 provides inertness to titanium on its surface and enables it used as an implant material for the orthopedic treatment such as fixation of the bone fracture [2]. Ti substrate is immersed into NaOH aqueous solution. The solution are heated at $140{\sim}200^{\circ}C$ for various time (10~720 minutes). After heat treatment, we take out the sample and immerse it into HCl aqueous solution for 1 hour. The acid treated sample is heated again at $500^{\circ}C$ for 3 hours [3]. Then, we culture osteoblast on the TiO2 nanowires. For investigating cell adhesion onto nanostructured surface, we conduct several tests such as MTT assay, ALP (Alkaline phosphatase) activity assay, measuring calcium expression, and so on. These preliminary results of the cell culture on the nanowires are foundation for investigating cell-material interaction especially with nanostructure interaction.

  • PDF

Effect of Low Level Laser Irradiation on Osteoblast Cell Proliferation and Differentiation after Implant Placement

  • Oh, Min-Seok;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Lim, Sung-Chul;Son, Jun-Sik
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.42-47
    • /
    • 2009
  • Objective : The purpose of this study was to evaluate the effects of low level lasers on bone healing and new bone formation around titanium dental implants in canine models. 18 oxidized surface treated implants and a Dens-bio laser were used. Study design : Low level lasers were irradiated with a total of 8J for 4 minutes by pulse wave type and 1 minute by continuous type. For the experimental group, a low level laser was used to irradiate the first premolar implant's insertion area at the time of insertion, a low level laser was used to irradiate the second premolar implant's insertion area daily for one week after implant insertion, and a low level laser was used to irradiate the third molar implant's insertion area daily for 2 weeks postoperatively. At the conclusion of the study, sacrificed tissue sections were made from investing tissue and observed under an optical microscope. Results : The rate of new bone formation around the implant showed no significant difference between the control group and the experimental group. New bone formation rates of the control and experimental group 2 weeks following implant placement were higher than that of immediately after implant placement and 1 week after implant placement. Conclusions : Based on these results, a low-level laser showed no statistically significant increase in bone formation following implant placement.

  • PDF

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

EFFECT OF CHEMICAL TREATMENT ON THE BIOACTIVITY OF TITANIUM (화학적 처리가 티타늄의 생체활성도에 미치는 영향)

  • Min Kwan-Sik;Lee Min-Ho;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.562-572
    • /
    • 2005
  • Statement of problem : Titanium is widely used as an implant material lot artificial teeth. Also, studies on surface treatment to form a fine passive film on the surface of commercial titanium or its alloys and improving bioactivity with bone have been carried out. However, there is insufficient data about the biocompatibility of the implant materials in the body. Purpose: The purpose of this study was to examine whether the precipitation of apatite on titanium metal is affected by surface modification. Materials and methods: Specimens chemically washed for 2 minute in a 1:1:1.5 (in vol%) mixture of 48% HF 60% $HNO_3$ and distilled water. Specimens were then chemically treated with a solution containing 97% $H_2SO_4$ and 30% $H_2O_2$ at $40^{\circ}C$S for 1 hour, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface were examined with TF-XRD, SEM, EDX and XPS. Also, commercial purity Ti specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. Conventional aluminium and stainless steel 316L were also implanted for comparison. Results and conclusions : The results obtained were summarized as follows. 1. An amorphous titania gel layer was formed on the titanium surface after the titanium specimen was treated with a $H_2SO_4$ and $H_2O_2$ solution. The average roughness was $2.175{\mu}m$ after chemical surface treatment. 2. The amorphous titania was subsequently transformed into anatase by heat treatment at $400^{\circ}C$ for 1 hour. 3. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $46.98{\mu}m$ in chemically-treated Ti, and 52.20, 168.65 and $100.95{\mu}m$ respectively in commercial pure Ti, aluminum and stainless steel 316L without any treatment.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE (기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰)

  • Whang, Yun-Hi;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.741-755
    • /
    • 1995
  • Currently titanium is the material of choice for implants because of its biological acceptance. This high degree of biocompatibility is thought to result, in part, from the protective and stable oxide layer that presumably aids in the bonding of the extracellular matrix at the implant-tissue interface. Endosseous dental implants are interfaced with bone, connective tissue, and epithelium when implanted into the jaw bone. The soft tissue interface including connective tissue and epithelium is one of the most critical factors in the determination of implant maintenance and prognosis. For maintenance of failing or failed implants, it is essential to treat the implant fixture surface to remove bacterial endotoxins and make a surface tolerated by surrounding soft and hard tissues. In this study, the effect of mechanical treatment on titanium plasma sprayed implant on adhesiveness and proliferation of human gingival fibroblasts and changed surface characteristics were studied. titanium plasma sprayed discs manufactured by Friedrichsfeld company were treated with loaw speed stone bur, a rubber point and a jetpolisher. Its surface components were analyzed with Energy dispersive X-ray spectroscopy to evaluate whether the surface characteristics were altered or not. To observe the spreading pattern of the human gingival fibroblasts which attached to the all specimens author used the scanning electron microscope. The results were as follows : Pure titanium and plasma sprayed titanium, stone polished titanium showed titanium peak and small amout of aluminum, so there was no alteration on surface characteristics. Under the scanning electron microscopic examination in the initial attachment of human gingival fibroblast, there was a slight enhancement in pure titanium, stone polished titanium than plasma sprayed titanium. After 6 hours, the pure titanium and stone polished titanium showed human gingival fibroblasts were elongated and connected with numerous processes. Human gingival fibroblasts were more intimately attached on the pure titanium discs than on the other discs. The human gingival fibroblasts attached on the plasma sprayed titanium by thin and elongated processes. After 24 hours, the human gingival fibroblasts connected with each other via numerous processes and compeletly covered the pure titanium and stone polshed titanium discs. Human gingival fibroblasts had multiple point contacts with more long and thin lamellopodia and showed a little bare surface on plasma sprayed titanium discs.

  • PDF

Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption (임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료)

  • Choi, Yu-Sung
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

Treatment of Peri-implantitis: Cases Report (임플란트 주위염의 치료: 증례보고)

  • Sung, Hun-Mo;Kim, Kyoung-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.112-123
    • /
    • 2013
  • This study aims to investigate the clinical outcome following treatment of peri-implantitis lesions. Five subjects with 7 implants were treated with surgical approach. Four subjects with 6 implants were initially treated with non-surgical approach or hygiene control. However, inflammation was not resolved and more bone loss was found. Therefore, surgical treatment was performed. After surgical exposure of the defect, granulation tissue was removed and implant surface was treated using tetracycline and chlorhexidine. Then, the flaps were sutured. The wound healing was performed in a non-submerged mode. The present finding demonstrates stable results without progression of bone loss. In one subject, deep V shaped bone defect was filled with bone substitute (ICB, CanCellous Bone, Rockey Mountain Tissue Bank, USA), and resorbable membrane (Lyoplant$^{(R)}$, B.Braun Aesculap AG, Germany) was placed over the grafted defect and healing abutment was connected. However, the inflammation was not resolved and more bone loss was found. At one month after regenerative surgery, the implant was removed.