• 제목/요약/키워드: surface-modification technology

검색결과 658건 처리시간 0.027초

Process Characteristics for $YB_{2}Cu_{3}O_{7-d}$ Films Fabricated by Single Target Sputter and Surface Modification Technique

  • Lee, Eue-Jae
    • 한국재료학회지
    • /
    • 제5권5호
    • /
    • pp.598-605
    • /
    • 1995
  • Thin films of $YB_{2}Cu_{3}O_{7-d}$ were prepared on various substrated of MgO(100), $SrTiO_{3}$, and $LaAlO_{3}$ by using off-axis magentron sputtering methods and annealing in-situ. The prarameters of film fabrication processes had been optimized through a "follow the lcoal maxima" strategy to yield good quality films in therms of the critical temperature $T_{c}$ and the critical current density $J_{c}$. Optimizedproecsses employing a plane magndtron and an cylindrical magnetron yielded $T_{c}$>90K along with $J_{c}$$10^{6}$A/$\textrm{cm}^2$ at 77K and > 2${\times}$$10^{7}$A/$\textrm{cm}^2$ at 5K. The sampels, however, showed degradationinthe properties, after chemical etching for fabrication of microbridges with the line width of 2-10 mocrons. In particular, the value of $T_{c}$ for the microbridges of 2microns was as small as 80%. The degradation was strongly dependent on the line width through a formula : $T_{c}$(e)=$T_{c}$)b) [1-a exp(-1000 bL)} where $T_{c}$(e) and $T_{c}$ (b) are the values of $T_{c}$ in the absolute scale measured after and before chemical etching, respectively and L is the line width in mm. By utilizing a best fitting technique, the proper constant values of a and to b were found as exp(-1.2) and 0.22, respectively. This formula was very useful in estimatiing the upper limit of the device operationtemperature.

  • PDF

대기압 플라즈마를 이용한 폴리우레탄 소재의 접착력 향상 (II) (Adhesion Enhancement of Polyurethane Foam Using Atmospheric Plasma (II))

  • 심동현;설수덕;오상택
    • 접착 및 계면
    • /
    • 제8권3호
    • /
    • pp.1-8
    • /
    • 2007
  • 폴리우레탄 폼 소재에 평판형 플라즈마 전처리 방식을 적용시켜 접촉각 및 접착력을 향상시켰다. 플라즈마 반응기의 최적의 반응조건을 조사하기 위해서 반응가스(질소, 아르곤, 산소, 공기), 가스의 유량(30~150 mL/min), 그리고 반응시간(0~30초) 등을 변화시켜 전처리하여 진공식 플라즈마 방식과 비교 검토하였다. 처리 후 소재의 표면 변화는 SEM과 ATR-FTIR을 이용하여 측정하였다. 폴리우레탄 폼에서 질소의 유량이 100 mL/min이고 반응시간이 10초일 때 접촉각의 저하에 따른 가장 좋은 접착력의 결과를 보여 주었다. 결과적으로 평판형 플라즈마 조작 방식에 의한 처리로 폴리우레탄 폼의 접촉각과 접착박리강도가 개선되었음을 확인하였다.

  • PDF

실리콘 아크릴레이트를 함유하고 있는 코팅필름의 물성 (Properties of Coating Film Containing Silicone acrylate)

  • 이봉우;방문수;홍진후;김대준;김현중
    • 접착 및 계면
    • /
    • 제3권4호
    • /
    • pp.10-18
    • /
    • 2002
  • 오늘날 플라스틱은 많은 분야에서 매우 중요한 역할을 하고 있으며, 플라스틱의 표면개질을 통해 경도, 마모, 내화학성과 같은 성질을 개선하여 성능을 향상시킬 수 있다. 본 연구의 목적은 polycarbonate, polymethylmethacrylate, acrylonitrilebutadienestyrene과 같은 플라스틱에 적용되는 기능성 하드코팅제를 개발하기 위한 것이다. 하드코팅제를 개발하기 위하여 먼저 실리콘아크릴레이트 올리고머(SAOE)를 합성하고, 이를 함유한 코팅필름을 PC 기재로 하였으며, 도막은 자외선경화에 의하였다. 실험의 결과에 의하면, SAOE를 함유하고 있는 도막의 물성이 SAOE를 함유하고 있지 않은 도막의 물성에 비해서 크게 향상되었다. 특히 코팅 조성물내에 1wt%의 SAOE가 함유되었을 때, 이로부터 얻어진 도막의 경도나 광택이 가장 우수함을 나타내었다.

  • PDF

Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies

  • Zhang, Ting;Zhang, Xinwei;Mao, Mengyun;Li, Jiayi;Wei, Ting;Sun, Huiqiang
    • Journal of Periodontal and Implant Science
    • /
    • 제50권6호
    • /
    • pp.392-405
    • /
    • 2020
  • Purpose: Titanium implants are widely used in the treatment of dentition defects; however, due to problems such as osseointegration failure, peri-implant bone resorption, and periimplant inflammation, their application is subject to certain restrictions. The surface modification of titanium implants can improve the implant success rate and meet the needs of clinical applications. The goal of this study was to evaluate the effect of the use of porous titanium with a chitosan/hydroxyapatite coating on osseointegration. Methods: Titanium implants with a dense core and a porous outer structure were prepared using a computer-aided design model and selective laser sintering technology, with a fabricated chitosan/hydroxyapatite composite coating on their surfaces. In vivo and in vitro experiments were used to assess osteogenesis. Results: The quasi-elastic gradient and compressive strength of porous titanium implants were observed to decrease as the porosity increased. The in vitro experiments demonstrated that, the porous titanium implants had no biological toxicity; additionally, the porous structure was shown to be superior to dense titanium with regard to facilitating the adhesion and proliferation of osteoblast-like MC3T3-E1 cells. The in vivo experimental results also showed that the porous structure was beneficial, as bone tissue could grow into the pores, thereby exhibiting good osseointegration. Conclusions: Porous titanium with a chitosan/hydroxyapatite coating promoted MC3T3-E1 cell proliferation and differentiation, and also improved osseointegration in vitro. This study has meaningful implications for research into ways of improving the surface structures of implants and promoting implant osseointegration.

Assembly of Magnetic Nano-Fe3O4@GSH-Au NCs Core-Shell Microspheres for the Visualization of Latent Fingerprints

  • Huang, Rui;Tang, Tingting
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850128.1-1850128.10
    • /
    • 2018
  • Glutathione (GSH), the protective agent and reducing agent, has been widely used to prepare gold nanoclusters (GSH-Au NCs) with stable fluorescence properties and negative charge of the surface. Meanwhile, polyethyleneimine (PEI) was used as the modification agent to synthesize magnetic ferroferric oxide nanoparticles ($Fe_3O_4$) with fantastic dispersibility and positive charge of the surface. Based on the electrostatic adsorption force, magnetic nano-$Fe_3O_4@GSH-Au$ NCs core-shell microspheres composed of magnetic $Fe_3O_4$ nanoparticles modified by PEI as the core and GSH-Au NCs as the shell were assembled. The prepared $Fe_3O_4@GSH-Au$ NCs microspheres harbored a uniform size (88.6 nm), high magnetization (29.2 emu/g) and excellent fluorescence. Due to the coordination bond action between Au atom and sulfhydryl (-SH), amino ($-NH_2$), carboxyl (-COOH) in sweat, $Fe_3O_4@GSH-Au$ NCs could combine with latent fingerprints. In addition, $Fe_3O_4@GSH-Au$ NCs with good fluorescence and magnetism could detect fingerprints on various objects. Significantly, the powders were not easy to suspend in the air, which avoided the damage to the health of forensic experts and the fingerprints by only powder contacting. Above all, $Fe_3O_4@GSH-Au$ NCs was successfully applied to the latent fingerprint visualization, which has great potential in forensic science.

전자선 조사에 의한 온도응답성 나노섬유 표면의 제조 및 특성분석 (Fabrication and Characterization of Thermo-responsive Nanofibrous Surfaces Using Electron Beam Irradiation)

  • 전현애;오환희;김영진;고재억;정호윤;강인규;김원일;권오형
    • 폴리머
    • /
    • 제32권4호
    • /
    • pp.359-365
    • /
    • 2008
  • 전기방사법에 의해 미생물 유래의 나노섬유 부직포를 제조하였고, 전자선조사에 의해 나노섬유상에 poly(N-isopropylacrylamide)(PIPAAm)을 그래프트함으로써 온도응답성 나노섬유표면을 제조하였다. 얻어진 나노섬유는 랜덤하게 배열되었으며 평균직경이 400 nm이었다. ATR-FTIR 및 ESCA 분석에 의해서 PIPAAm이 나노섬유 표면에 성공적으로 그래프트되었음을 확인하였다. PIPAAm을 그래프트 하지 않은 표면에서는 물접촉각의 변화가 없었으나, PIPAAm이 그래프트된 나노섬유 표면에서는 온도가 $37^{\circ}C$에서 $20^{\circ}C$로 바뀜에 따라 물접촉각이 감소하였다. 이러한 결과는 PIPAAm이 그래프트된 표면에서 높은 온도에서는 소수성의 특성을 가지다가, 낮은 온도에서는 PIPAAm 사슬이 수화되면서 친수성으로 바뀌었기 때문이다. 제조한 온도응답성 나노섬유는 조직적합성이 우수하였으며, 저온처리에 의해 배양세포가 원활히 탈착 회수됨을 알 수 있었다.

Negative ion beam sputter 법으로 증착한 DLC 박막의 특성 (I) (Properties of Diamond-like Carbon(DLC) Thin Films deposited by Negative Ion Beam Sputter (I))

  • 김대연;강계원;최병호
    • 한국재료학회지
    • /
    • 제10권7호
    • /
    • pp.459-463
    • /
    • 2000
  • 순수한 동적 결합반응이고 전하 누적이 없는 이온 임플란테이션, 새로운 재료 개발 등에 음이온을 직접 사용하는 새로운 연구가 진행되고 있으며, 이러한 관점에서 새로운 고체상의 Cs이온 법이 실험실 규모로 연구되고 있다. 본 논문에서는 음이온 Cs gun으로 DLC 박막을 실리콘 위에 제조하였다. 이 시스템은 가스가 필요없으므로, 고 진공에서 증착이 일어난다. C(sup)-빔 에너지는 80~150eV 사이에서 조절이 우수하였다. Raman 분석결과 박막의 DLC 지수, 즉$sp^3$비율은 이온 에너지 증가에 따라 증가하였으며, 미소 경도값 또한 7에서 14GPa로 증가하였다. DLC박막의 표면 평균거칠기(Ra)는 ~1$\AA$정도로 아주 매끈하였으며, 불순물이 내재되지 않는 박막을 얻을 수 있었다.

  • PDF

투명 유-무기 하이브리드 하드코팅 필름 제조 및 SiO2 또는 ZrO2함량에 따른 필름의 물성 (Preparation of Transparent Organic-Inorganic Hybrid Hard Coating Films and Physical Properties by the Content of SiO2 or ZrO2 in Their Films)

  • 설현태;나호성;권동주;김정섭;김대성
    • 한국재료학회지
    • /
    • 제27권1호
    • /
    • pp.12-18
    • /
    • 2017
  • Transparent organic-inorganic hybrid hard coating films were prepared by the addition of $SiO_2$ or $ZrO_2$, as an inorganic filler to improve the hardness property, filler was highly dispersed in the acrylic resin. To improve the compatibility in the acrylic resin, $SiO_2$ or $ZrO_2$ is surface-modified using various silanes with variation of the modification time and silane content. Depending on the content and kind of the modified inorganic oxide, transparent modified inorganic sols were formulated in acryl resin. Then, the sols were bar coated and cured on PET films to investigate the optical and mechanical properties. The optimized film, which has a modified $ZrO_2$ content of 4 wt% markedly improved in terms of the hardness, haze, and transparency as compared to neat acrylate resin and acrylate resin containing modified $SiO_2$ content of 8 wt%. Meanwhile, the low transparency and high haze of these films slowly appeared at $SiO_2$ content above 10 wt% and $ZrO_2$ content of 5 wt%, but the hardness values were maintained at 2H and 3H, respectively, in comparison with the HB of neat acrylate resin.

Acrylonitrile/Sodium Allylsulfonate 공중합체 방사선 접목을 이용한 다공성 Polytetrafluoroethylene 지지체의 친수화 (Hydrophilization of a Porous Polytetrafluoroethylene Supporter by Radiation Grafting Poly(Acrylonitrile-co-Sodium Allylsulfonate))

  • 박병희;손준용;윤기석;신준화
    • 폴리머
    • /
    • 제38권3호
    • /
    • pp.293-298
    • /
    • 2014
  • 본 연구에서는 방사선을 이용하여 다공성 polytetrafluoroethylene(PTFE) 지지체에 acrylonitrile(AN)과 친수성 작용기를 가진 sodium allylsulfonate(SAS)를 접목시켜 복합 연료전지막의 지지체로 사용되는 친수화 다공성 지지체를 제조하였다. SAS/AN의 몰비율, 단량체 농도, 방사선의 조사선량에 변화를 주어 제조된 지지체의 물성을 평가하였다. 제조된 지지체의 FTIR 분석을 통하여 각 단량체들이 다공성 PTFE 지지체에 성공적으로 그래프팅되었음을 확인하였다. 또한 FE-SEM과 gurley number 측정을 이용하여 그래프트율이 증가할수록 지지체 표면의 기공이 감소하는 것을 관찰하였고, 그래프트율, 접촉각, TBO(toluidine blue O) uptake 분석을 통해 그래프트율이 증가됨에 따라 제조된 지지체의 친수화도가 증가하는 것을 확인하였다.

CAD/CAM 전문 인력 양성을 위한 교육 및 업무의 필요성 (The Need of Education and Practice to Bring Up CAD/CAM Experts)

  • 나정숙
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.365-380
    • /
    • 2016
  • Purpose: The purpose of this study was to ascertain the need to reform curriculums for digital experts in a way that include the practical and educational aspects of dental labs by determining why educational reforms are needed to comply with changes in dental technology business that are brought by the applications of digital scanning and what changes are being actually brought by the use of CAD/CAM. Methods: This study analyzed the need of education and practice in relation to CAD/CAM by using the independent sample t-test and One-way ANOVA. in accordance with the participants demographic characteristics and job-related variables and factors related to CAD/CAM, and provided only some of the analysis results that were found statistically significant. Concerning the need of education and practice in relation to CAD/CAM, the study also used the independent sample t-test to measure difference in the perception of that need within each of the three groups, or those of job performance, job efficiency and knowledge gain at the signficance level of ${\alpha}=.05$. Results: Dental technologists surveyed here were perceiving that the use of CAD/CAM would bring changes in their job performance, job efficiency and knowledge gain. They were expecting that the biggest changes would be made in work climate and product quality as sub-areas of job performance. However, they said that in terms of job efficiency, the use of CAD/CAM would change job contribution, job satisfaction and job efficiency, but not lead to staffing. These results suggest that more special programs for CAD/CAM education are needed to bring up CAD/CAM experts who are more specialized. Conclusion: Among 13 skills related to CAD/CAM, what is most needed to be educated to dental technologists was "molding the occlusal surface" (M=4.19), followed by "designing the 3-D work" (M=4.17), "final shape modification" (M=4.16), "molding the border" (M=4.15) and "checking the fit of prothesis" (M=4.14) in order.