• 제목/요약/키워드: surface treatments

검색결과 1,426건 처리시간 0.03초

고력볼트 접합부표면의 방식도장변수에 따른 체결력 평가 (Evaluation on Clamping Force of High Strength Bolts By Coating Parameters of Faying Surfaces)

  • 나환선;이현주
    • Corrosion Science and Technology
    • /
    • 제11권2호
    • /
    • pp.48-55
    • /
    • 2012
  • Clamping force of a high strength bolt is reduced by a certain period of time after the initial set-up. In case of special treatments on faying surfaces such as protective coating, clamping force is relaxed more severely. Tests for slip critical joints subject to various faying surface parameters were conducted. Five different surface treatments were tested including mill scale surface, blast surface, rust surface and coated surfaces. Each specimen was composed of F10T M20 of high strength bolts and steel plates. Based on the result of slip coefficient test, blast treatment surface showed 0.59, rust treatment surface showed 0.54 and inorganic zinc treatment surface exhibited 0.44. Clean mill treatment surface and red lead paint treatment surface were 0.23, 0.21 respectively. It is identified that the slip coefficient in Korean structural design guide should be determined for various surface conditions. Subsequently from long term relaxation test of ASTM A 490 high strength bolts, relaxation of no-coated surfaces such as blast, clean mill, rust treatment, the loss of initial clamping load was 10.5%, 13.6% and 7.9% for 1,000 hours, while the loss of initial clamping force was reached as 15.0%, 18.7% more than the required redundancy 10% in case of inorganic zinc and red lead painted treatment. It is required that the limit of relaxation on coated faying surface should be established separately for various surfaces.

표면처리용 형광증백제의 정량분석법에 대한 연구 (Development of Quantitative Analysis of the Fluorescent Whitening Agents Used for Surface Treatments)

  • 이지영;김철환;박종혜;김은혜;위상욱;성용주;허영준;김연오;황인영
    • 펄프종이기술
    • /
    • 제47권3호
    • /
    • pp.34-39
    • /
    • 2015
  • Fluorescent whitening agents (FWAs) are widely applied in the papermaking process to improve the CIE whiteness and the ISO brightness of papers. Large amounts of FWAs are used in the paper and paperboard industry, but no standard method exists for quantitative FWA analysis. Therefore, a new method is needed to analyze the presence of FWAs in paper and paperboard to control their additions and applications. In particular, FWA analysis must concentrate on those used for surface treatment of paper because their use in surface applications has increased recently. The purposes of this study were to measure the optical properties of papers surface-treated with oxidized starch containing FWAs and to deduce the regression equations for the quantitative analysis of FWAs used for surface treatments. Surface sizing was carried out to treat the surface of a base paper with T-FWA and H-FWA, and the pickup weight of the surface sized paper was measured to determine the real weight of FWAs transferred onto the paper surface. After surface sizing and preconditioning, the paper was evaluated for CIE whiteness, ISO brightness, fluorescence index, and reflectance at 440 nm using an Elrepho spectrophotometer. The CIE whiteness and the ISO brightness increased linearly as FWA content increased. The fluorescence index and the reflectance showed linear relationships with T-FWA and H-FWA. Linear regression equations were determined for the quantitative analysis of FWAs used for surface treatments.

인공강우 시 나지교란사면 토사유출에 미치는 다짐처리의 영향 (Effects of Surface Compaction Treatment on Soil Loss from Disturbed Bare Slopes under Simulated Rainfalls)

  • 박상덕;신승숙;김선정;최병구
    • 한국수자원학회논문집
    • /
    • 제46권5호
    • /
    • pp.559-568
    • /
    • 2013
  • 토양의 다짐은 강우 시 지표유출 및 토사유출에 큰 영향을 끼친다. 다짐은 체적밀도 증가, 전단강도 증가, 공극률 변형, 투수계수 등과 같은 토양특성 변화를 야기하기 때문이다. 본 연구는 인공강우 실험을 활용하여 개발지의 사면조건과 유사한 나지교란사면에서 표면의 다짐처리가 지표유출 및 토사유출에 미치는 영향을 파악하였다. 표면처리(다짐, 비다짐), 강우강도(68.5mm/hr, 95.6mm/hr), 사면경사($5^{\circ}$, $12.5^{\circ}$, $20^{\circ}$)의 각 조건별 3회 반복하여 총 36회의 강우모의에 따른 지표유출 및 토사유출을 측정하였다. 연구결과, 다짐처리 후 토양의 체적밀도 및 전단강도는 유의적으로 증가하였다. 그러나 이러한 물리적 특성의 변화가 지표유출에 미치는 영향은 강우강도와 사면경사에 따라 다르게 반응하였다. 평균 토사유출량은 강우강도와 사면경사가 증가함에 따라 유의적으로 증가하였다. 또한, 토사유출량은 강우강도와 사면경사 별 다짐처리 유 무에 따라 다른 반응을 보였다. 완경사($5^{\circ}$)에서는 다짐처리에서 더 많은 토사가 유출되었으나, 급경사($20^{\circ}$)에서의 다짐처리는 토사유출을 감소시키는 역할을 한 것으로 나타났다. 나지교란사면에서는 토사유출에 대한 다짐효과의 천이구간이 존재하는 것으로 파악되며, 본 연구의토양조건 및 강우조건에서 천이구간은 완경사와 급경사 사이로서 사면경사 $10{\sim}15^{\circ}$ 범위에 존재하는 것으로 판단된다.

Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials

  • Lee, Ki-Sun;Shin, Myoung-Sik;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.350-357
    • /
    • 2017
  • PURPOSE. The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS. One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with $50{\mu}m$ alumina, and airborne abrasion with $110{\mu}m$ silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS. Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION. Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.

Surface treatment, liquid, and aging effects on color and surface properties of monolithic ceramics

  • Sertac Sariyer;Meryem Gulce Subasi
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.174-188
    • /
    • 2024
  • PURPOSE. The purpose of this study was to investigate the effects of surface treatments, liquids, and aging on color, translucency, and surface properties of monolithic ceramics. MATERIALS AND METHODS. Lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) ceramics (n = 135 each) were cut and divided into three groups [crystallization+glaze (single stage), crystallization-glaze (two stages), and crystallization-polish (two stages)]. One sample from each group was examined using scanning electron microscopy (SEM). Remaining samples were divided into four subgroups (distilled water, coffee, grape juice, and smoothie) (n = 11 each), stored for 12 d in the respective liquids, and thermally aged. One sample from each subgroup was analyzed using SEM. The color, gloss, and roughness values of the samples were analyzed after surface treatment (initial) and storage under different liquids+aging conditions. The initial data and both the aged data and data change values were analyzed using robust two- and three-way analyses of variance. RESULTS. The glazed groups exhibited smoother surfaces. Ceramic type and ceramic-surface treatment interactions affected the initial translucency parameter (TP) (P < .001) and the initial and aged roughness values (P ≤ .001). Surface treatment type affected the color change (P < .001), and ceramic type affected the aged TP values (P < .001). Type of ceramic, surface treatment, and their interactions affected both the initial and aged gloss (P ≤ .001) and TP change values (P ≤ .015). Surface treatment type and ceramic-surface treatment interactions affected the gloss change values (P ≤ .001). CONCLUSION. Although both ceramics and all surface treatments are clinically applicable, crystallization-glaze is recommended. When gloss and smoothness are important or when translucency is important, ZLS or LDS may be preferred, respectively.

수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구 (The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants)

  • 김선봉;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF