내식성 및 표면경도 향상을 위한 AISI 304L 스테인리스강의 저온 플라즈마질화 프로세스 (Low Temperature Plasma Nitriding Process of AISI 304L Austenitic Stainless Steels for Improving Surface Hardness and Corrosion Resistance)

  • 이인섭
    • 대한금속재료학회지
    • /
    • 제47권10호
    • /
    • pp.629-634
    • /
    • 2009
  • The effects of processing parameters on the surface properties of the hardened layers processed by the low temperature plasma nitrocarburizing and the low temperature two-step plama treatment (carburizing+nitriding) were investigated. The nitrogen-enriched expanded austenite structure (${\gamma}_N$) or S phase was formed on all of the treated surface. The surface hardness reached up to 1200 $HV_{0.025}$, which is about 5 times higher than that of untreated sample (250 $HV_{0.1}$). The thickness of hardened layer of the low temperature plasma nitrocarburized layer treated at $400^{\circ}C$ for 40 hour was only $15{\mu}m$, while the layer thicknesss in the two-step plama treatment for the 30 hour treatment increased up to about $30{\mu}m$. The surface thickness and hardness increased with increasing treatment temperature and time. In addition, the corrosion resistance was enhanced than untreated samples due to a high concentration of N on the surface. However, higher treatment temperature and longer treatment time resulted in the formation of $Cr_2N$ precipitates, which causes the degradation of corrosion resistance.

Analysis of Extreme Sea Surface Temperature along the Western Coastal area of Chungnam: Current Status and Future Projections

  • Byoung-Jun Lim;You-Soon Chang
    • 한국지구과학회지
    • /
    • 제44권4호
    • /
    • pp.255-263
    • /
    • 2023
  • Western coastal area of Chungnam, including Cheonsu Bay and Garorim Bay, has suffered from hot and cold extremes. In this study, the extreme sea surface temperature on the western coast of Chungnam was analyzed using the quantile regression method, which extracts the linear regression values in all quantiles. The regional MOHID (MOdelo HIDrodinâmico) model, with a high resolution on a 1/60° grid, was constructed to reproduce the extreme sea surface temperature. For future prediction, the SSP5-8.5 scenario data of the CMIP6 model were used to simulate sea surface temperature variability. Results showed that the extreme sea surface temperature of Cheonsu Bay in August 2017 was successfully simulated, and this extreme sea surface temperature had a significant negative correlation with the Pacific decadal variability index. As a result of future climate prediction, it was found that an average of 2.9℃ increased during the simulation period of 86 years in the Chungnam west coast and there was a seasonal difference (3.2℃ in summer, 2.4℃ in winter). These seasonal differences indicate an increase in the annual temperature range, suggesting that extreme events may occur more frequently in the future.

지표 특성 변화에 대한 평형온도의 반응 연구 : EBM 연구 (On response of Surface Equilibrium Temperature for Change of Surface Characteristics : An EBM Study)

  • 서예원;추정은;하경자
    • 한국제4기학회지
    • /
    • 제24권2호
    • /
    • pp.1-11
    • /
    • 2010
  • 지표 특성 차이에 따라 외부강제력에 대한 차별적인 반응을 보이는 지표 평형온도 분포를 실험하기 위해 에너지 균형 모형(Energy Balance Model, EBM)이 사용되었다. EBM은 입사되는 복사에너지가 각 위도별로 수송되는 에너지와 방출되는 복사에너지의 합과 균형을 이루었을 때의 온도를 산출한다. 지구의 에너지 원천인 태양복사에너지를 전지구 에너지 균형에 있어 중요하게 취급하기 위하여 위도별 알베도 변화뿐만 아니라 해륙의 분포 차이에 따른 에너지 균형을 고려한 지구 평형온도 분포에 관한 실험이 수행되었으며, 입사되는 태양복사에너지량을 강제력으로 하여 위도별 알베도의 선형적인 증감, 극지역 알베도의 5%, 10%, 15% 증감에 대한 반응, 극과 중위도 지역에서의 상반된 증감에 대한 반응을 실험하였다. 그리고 얼음-알베도 피드백의 유무에 대한 실험도 수행되었다. 극지역의 알베도를 증가시키면 입사되는 태양에너지를 차단시켜 위도별 열수송을 감소시키는데 이는 극지역을 저에너지 상태로 유지시킴으로써 저위도에서부터의 에너지 수송을 강화시킨다. 이러한 수송량의 차이로 인해 중위도 지역의 온도 변화는 극지역에 비해 크게 나타난다. 육지는 해양에 비해 열용량이 작기 때문에 평형온도에 도달하는 시간이 짧으며 알베도에 따른 온도변화에 민감하여 해양과의 온도차이를 유발시킨다. 따라서 평형온도는 지표가 가지는 특성인 알베도와 열용량의 차이에 따라 다르게 나타나며 알베도가 증가함에 따라 감소하고 열용량이 작을수록 변화율이 큰 특징이 있다. 얼음-알베도 피드백은 알베도의 선형적인 증가에 따른 지구 평형온도의 감소를 가속화시키지만 국지적으로는 비선형적인 감소를 보인다.

  • PDF

GRID/GIS 및 RS 자료를 이용한 에너지 평형 모형으로부터의 국지적 지표 온도 산출 (Estimation of Local Surface Temperature from EBM with the Use of GRID/GIS and Remote Sensed data)

  • 신선희;하경자;김재환;오현미;조명희
    • 대한원격탐사학회지
    • /
    • 제20권2호
    • /
    • pp.103-116
    • /
    • 2004
  • 지표 온도를 산출하는 중규모 대기 모형은 일반적으로 태양 복사의 직달 일사량에 대하여 경사진 지형의 효과를 고려하지 않는다. 이는 실제 태양 복사량의 국지적 차이를 나타내지 못하며, 그 결과 국지적인 지표 온도에서의 큰 오차를 가져온다. 따라서 지형의 기하학적 특성뿐만 아니라 지표의 식생 특성을 고려함으로써, 정확한 국지적 지표 온도를 나타내고자 하였다. 본 연구의 목적은 GIS의 그리드 모형을 적용한 에너지 균형 모형(EBM)을 사용하여 진단적으로 지역적 지표 온도를 산출하는 것이다. 본 연구에서, 한반도 남부 지역의 지형적 비균질성은 그리드 내의 지형 방위각과 경사각의 함수인 조도각의 항으로써 흡수된 지표 일사량 계산에 고려되었다. 또한 지표 온도 변화에 주요한 변수가 되는 지표의 식생 특성이 NDVI의 항으로 사용하였다. 지표의 경사진 지형의 효과와 식생 특성이 고려된 지표 온도의 상세한 지역적 분포가 연구 결과로써 제시되었다. 이러한 지역적 지표 온도 분포는 저층 대기에서 지형에 의한 지역 순환을 형성할 수 있으며, 실제 자연에서의 지역 순환을 더욱 잘 설명할 수 있을 것이다.

Downscaling of MODIS Land Surface Temperature to LANDSAT Scale Using Multi-layer Perceptron

  • Choe, Yu-Jeong;Yom, Jae-Hong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.313-318
    • /
    • 2017
  • Land surface temperature is essential for monitoring abnormal climate phenomena such as UHI (Urban Heat Islands), and for modeling weather patterns. However, the quality of surface temperature obtained from the optical space imagery is affected by many factors such as, revisit period of the satellite, instance of capture, spatial resolution, and cloud coverage. Landsat 8 imagery, often used to obtain surface temperatures, has a high resolution of 30 meters (100 meters rearranged to 30 meters) and a revisit frequency of 16 days. On the contrary, MODIS imagery can be acquired daily with a spatial resolution of about 1 kilometer. Many past attempts have been made using both Landsat and MODIS imagery to complement each other to produce an imagery of improved temporal and spatial resolution. This paper applied machine learning methods and performed downscaling which can obtain daily based land surface temperature imagery of 30 meters.

개의 體熱에 대한 연구 (A Study on Canine Body Surface Temperature)

  • 서지민;송근호;이버들;조성남;김덕환;이영원;김명철;조규완;김승호
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.121-124
    • /
    • 2002
  • This study was performed to examine the distribution of mean body surface temperature in 11 clinically healthy dogs. In stable state, ventral and dorsal part of each individual is scanned by digital infrared thermography. The body surface temperature of dorsocranial(DCr), dorsocaudal(DCd), ventrocranial(VCr) and ventrocaudal(VCd) regions were measured by Region Of Interersts(ROI). The mean body surface temperatures of adult dogs were higher than those of puppies in each regions. In addition mean body surface temperature of the ventral region was higher than that of dorsal region.

대형 틸팅패드 저어널베어링의 THD 성능에 관한 실험적 연구 (Experimental Investigation on the THD Preformance of a Large Tilting Pad Journal Bearing)

  • 하현천;김경웅;김영춘;김호종
    • Tribology and Lubricants
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1993
  • The thermohydrodynamic(THD) performance of a large tilting pad journal bearing in laminar and turbulent flow regions is investigated experimentally. The continuous shaft surface temperature, and bearing surface temperature are measured along with the shaft speed and the bearing load for various flow rates. It is observed that the shaft surface temperature is constant in the circumferential direction and increases with the increase of shaft speed in both low and high shaft speed region, however, there exist transition region where the shaft surface temperature decreases with the increase of shaft speed. When the turbulence occurs in the lubricant film, both the inlet and maximum bearing surface temperature steeply increase and the temperature gradient in the circumferential direction decreases.

표면온도 및 조도분포가 있는 경우 난류경계층의 완충층 거동에 관한 연구 (A Study on the Behavior of Buffer Layer in Turbulent Boundary Layer with Variation of Surface Temperature and Roughness)

  • 정동빈
    • 수산해양기술연구
    • /
    • 제35권1호
    • /
    • pp.83-92
    • /
    • 1999
  • In this paper, the wind tunnel test was carried to investigate the behavior of buffer layer in turbulent boundary layer with variation of surface temperature and roughness. The results were as follows; 1. The velocity in turbulent boundary layer was increased when the roughness height within viscous sublayer thickness was increased. 2. When the surface temperature was increased, the density of air was decreased and the velocity in turbulent boundary layer was increased. Thus, the thickness of turbulent boundary layer was decreased. 3. When the roughness height and surface temperature was increased simultaneously, the thickness of turbulent boundary layer was decreased. 4. The decrement of the thickness of turbulent boundary layer was more effected by the increment of the roughness height rather than the increment of surface temperature. 5. In this study, it was found that the condition of the highest velocity n turbulent boundary layer was the temperature 333K and roughness #100.

  • PDF

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

전기자극이 정상인과 요통환자의 체표면 온도 변화에 미치는 영향 (The Effect of Electrical Stimulation on the Changes of Skin Temperature in Normal and Low Back Pain Patients)

  • 박돈목;임정도
    • 대한물리치료과학회지
    • /
    • 제5권4호
    • /
    • pp.817-830
    • /
    • 1998
  • The purpose of this study is to investigate the relationship between effects of TENS (Transcutaneous Electrical Nerve Stimulation) and IFC(Interferrential Current Therapy) to the change of body surface temperature. Cases are 22 normal persons and 22 patients with low back pain. Digital Infrared Thermal Imaging system was used for the detection of body surface temperature. 50Hz in frequency and 25-35mA in intensity were applied to TENS and IFC, 15 and 10 minutes on each. The results were follows ; 1. TENS and IFC has on effect of decreasing surface temperature, which would be from cardiovascular factors. (P<0.001) 2. The influence of IFC to the body surface temperature is greater than TENS, and it seems to be vasoconstriction of sympathetic activity. 3. There were no significant differences of body surface temperature between the two groups before and after electrical stimulation.

  • PDF