• 제목/요약/키워드: surface superconductivity

검색결과 265건 처리시간 0.019초

Estimation of surface emissivity for conduction-cooled metal plates at cryogenic temperatures

  • Chang, Ho-Myung;Lee, Gyong-Hyon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.38-41
    • /
    • 2008
  • The relation between surface emissivity and temperature distribution is experimentally and analytically investigated for a conduction-cooled metal plate in vacuum. Experimental set-up consists of a rectangular metal plate placed vertically in a cryostat and thermally anchored to the coldhead of a GM cryocooler at the top. Temperature is measured at a number of locations over the plate with platinum resistors mounted on the plate. A parallel analysis on the balance of heat conduction through the plate and thermal radiation on its surface is performed to numerically calculate the temperature distribution having the same boundary conditions as experiment. By comparing the two results, an average emissivity of the plate is roughly estimated for different metal plates and different surface conditions. The estimated emissivity in present study is less than the listed values for highly polished stainless steel, and meets a fairly good agreement for oxidized copper surface.

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • 제2권1호
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Organic Superconductors

  • Kang, W.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2003년도 High Temperature Superconductivity Vol.XIII
    • /
    • pp.24-24
    • /
    • 2003
  • PDF

광전자실험을 이용한 $Y(Pr)Ba_2Cu_4O_8$ 물질의 체인 전자 구조분석 (Photoemission Studies on Chain Electronic Structures of $Y(Pr)Ba_2Cu_4O_8$)

  • 부영건;정원식;한가람;김창영
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.158-162
    • /
    • 2012
  • $Y(Pr)Ba_2Cu_4O_8$ system is one of the most studied high temperature superconductors. Substitution of Pr for Y in this system suppresses $T_c$ and superconductivity finally disappears at a high Pr doping. There are competing theories for the suppression of $T_c$ but systematic experimental results are very rare. In order to find the change in Fermi surface topology which can affect the superconductivity, we have performed angle-resolved photoemission studies on single crystal samples of $YBa_2Cu_4O_8$ and $PrBa_2Cu_4O_8$. While the Fermi surface of $YBa_2Cu_4O_8$ shows a similar topology to those of other cuprates, we observe only 1D like band structures in $PrBa_2Cu_4O_8$. We find no significant differences in the chain band for both samples.

액체질소의 연면 방전 기초 특성 연구 (Basic Study on Characteristics of Surface Flashover in L$N_{2}$)

  • 정종만;백승명;김영석;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.237-240
    • /
    • 2002
  • Fiberglass - reinforced plastic (FRP) can have high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen(L$N_{2}$). In this study, we discussed the characteristics of surface flashover on FRP in L$N_{2}$ for applying it to spacer of a superconducting power equipment. We distinguished four types of surface flashover along solid insulator with arrangement of electrodes and tested the surface flashover voltage of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property.

  • PDF

Evaluation of Mg size dependence on superconductivity of MgB2

  • Sinha, B.B.;Jang, S.H.;Chung, K.C.;Kim, J.H.;Dou, S.X.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.39-43
    • /
    • 2013
  • $MgB_2$ bulk samples are synthesized through solid state reaction route using Mg precursors with different particle size by keeping the boron precursor unchanged. Scanning electron microscopy study of the fractured surface for all the samples depicts quite distinct structure depending on the Mg precursor. Big size of Mg precursor resulted in to largely elongated and deep pores while smaller one gave roughly ellipsoidal and shallow pore structure. Influence of the Mg particle size on the grain to grain connectivity reflected in the critical current density value which was greater for samples with smaller Mg precursor. All the synthesized samples undergo a superconducting transition at around 36.5 K irrespective of different Mg precursor particle size.

A Study on the Electrical and Mechanical Properties of Conduction Cooling HTS SMES

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Shin, H.S.;Kim, H.J.;Seong, K.C.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.29-32
    • /
    • 2009
  • The conduction cooling HTS SMES magnet is operated in cryogenic temperature. The insulation design at cryogenic temperature is an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction cooling HTS SMES. Specially, this paper was studied about high vacuum and cryogenic temperature breakdown and flashover discharge characteristics between cryocooler and magnet-coil. The breakdown and surface flashover discharge characteristics were experimented at cryogenic temperature and vacuum. Also, we were experimented about mechanical properties of 4-point bending test. From the results, we confirmed that about research between cryocooler and magnet-coil established basic data in the insulation design.

2축 정렬된 Ni 선재 위에 MOCVD법에 의한 NiO의 조직 및 표면 분석 (Texture and surface analysis of NiO prepared on biaxially textured Ni substrates by MOCVD method)

  • 선종원;김형섭;지봉기;박해웅;홍계원;박순동;정충환;전병혁;김찬중
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2002
  • The NiO buffer layers for YBCO coated conductor were prepared on textured Ni substrates by MOCVD method and the degree of texturizing and the surface roughness were analyzed X-ray pole figure and AFM and SEM. Processing variables were oxygen partial pressure and substrate temperature. (200) textured NiO layer was formed at 450~$470^{\circ}C$ and oxygen partial pressure of 1.67 Torr. Out-of-plane($\omega$-scan) and in-plane($\Phi$-scan) texture were $10.34^{\circ}$ and $10.00^{\circ}$ respectively. The surface roughness estimated by atomic force microscopy was in the range of 3.1~4.6 nm.

  • PDF

극저온냉동기 직냉형 진공시스템의 냉동부하 평가 (Evaluation of the required cooling capacity of the Cryocooler in the vacuum system)

  • 홍용주;박성제;김효봉;최영돈
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.171-173
    • /
    • 2003
  • The cryostat or dewar have been widely used for making and maintaining cryogenic and vacuum environments. The thermal performances of such cryogenic vacuum system mainly depend on the radiation heat transfer between hot and cold surface The characteristics of radiation heat transfer are complicated, because amounts of heat transfer depend on view factor, emissivities, and areas of thermal elements. In this study, the analysis of the radiation heat transfer in the small cryogenic vacuum system was performed using the surface to surface radiation model for evaluation of the required cooling capacity of the cryocooler.

  • PDF