• Title/Summary/Keyword: surface heating

Search Result 1,615, Processing Time 0.034 seconds

The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams (고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 1995
  • Lithium Fluoride (LiF; TLD-100) crystal chips are normally used as thermolu minescence dosimeters (abbreviated as NC-100) for estimating the absorbed dose to the skin of a patient or in a solid water phantom undergoing radiotherapy with megavoltage photon (6 and 15MV) beams. In general, investigation has revealed a reduction in the sensitivity of NC-100 chips after many runs through heating cycles. A TLD-100 chip laminated with gold plate (140${\mu}{\textrm}{m}$) on the upper surface layer of its face toward the photon beam (abbreviated as GC-100) has properties different from that of a NC-100 chip activated by incident photons and contaminant electrons with various lower energies coming from the gantry head and air. Activation of the valence band electrons of GC-100 chips by incident photons, positrons and electrons-which come from the gold plate by mainly pair production process and partly from Compton scattering-results in more enhanced signal intensity, higher response per monitor unit, as well as a good linearity with monitor units and independence of dose rate. Since the electron beams (6 and 15 MeV) do not have the probability of pair production process with gold plate, there is only a small difference (about a 3.3% increase for 15 MeV) in the signal gaps in the TL readout for electron beams between GC- and NC-100 chips. The 3.3% increase is entirely due to the buildup caused by the 140 m gold plate. The sensitivity of GC-100 chips is much more susceptible to high energy photon beams than electron one because of pair production. The interaction of high energy photon with a material of high atomic number, such as the good plate in this case, results in a considerably significant probability of pair production. The gold plate on the NC-100 chips acts as not only an intensifier of their signals but also acts as a filter of contaminant electrons in therapeutic high energy X-ray beams.

  • PDF

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Determination of Estrone by Adsorptive Stripping Voltammetry (흡착 벗김 전압전류법에 의한 에스트론의 정량)

  • Hong, Taekee;Kyong, Jin Burm;Lee, Hyun Jung;Czae, Myung-Zoon
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-39
    • /
    • 1999
  • Estrone such as estriol and estradiol can not be determined by votammetric methods, because these are electrochemically inactive in the potential windows for mercury drop electrode. Nitro-derivatives of estrone are electro active and nitration of estrone is accomplished by heating the solution involving estrone and sodium nitrite in a water-bath at $100^{\circ}C$ for 30 min. Such nitro-derivatives are determined directly by voltammetry. The electrochemical behavior for nitrated estrone was investigated by cyclic voltammetry. The trace estrone was determinated by differential pulse adsorptive cathodic stripping voltammetry. Nitrated estrone gives a well defined voltammetric wave at ca. - 0.61 V (vs. Ag/AgCl electrode). The electrochemical reaction was irreversible process in sodium borate buffer at pH 11 and nitrated estrone was strongly adsorbed on the surface of mercury electrode. The optimal experimental conditions for the determination of nitrated esterone were found to be 0.05 M sodium nitrate, 0.01 M sodium borate, pH 11.0, and an accumlation potential of 0.10 V (vs. Ag/AgCl). The detection limit was as low as $1{\times}10^{-9}M$ for estrone with 2 min accumulation time.

  • PDF

Root zone environments in two cropping system within a year for Kyoho grapes (포도 '거봉'의 2기작 재배에서 근권환경 특성)

  • 오성도;김용현
    • Journal of Bio-Environment Control
    • /
    • v.6 no.4
    • /
    • pp.235-241
    • /
    • 1997
  • This study was performed to investigate the behaviour of root zone environments under the control of soil temperature and tension of soil moisture near the root Bone of 'Kyoho' grapes tree grown on restricted root zone system in plastic greenhouse. Maximum diurnal air temperature inside plastic greenhouse ranged between 25.1 and 32.7$^{\circ}C$, and the average of nocturnal air temperature inside plastic greenhouse maintained at 18$^{\circ}C$ in winter season. Also the minimum diurnal relative humidity ranged between 50 and 55%, and the maximum nocturnal relative humidity ranged between 84 to 87%. At a depth of 15cm from soil surface, the average soil temperature maintained at 25.6$^{\circ}C$ for under-ground heating, and appeared to 17.4$^{\circ}C$ for unheated condition. Although the tension of soil moisture just after irrigation sharply decreased to pF 1.5, the tension of soil moisture at the depth of 15cm maintained at pF 2.0~2.2. It is suggested that the tension of soil moisture at the depth of 15cm might be used as the standard for the determination of irrigation set point. Effective drainage system is needed to prevent the spindly and succulent growth of vine trees grown in restricted root zone system.

  • PDF

Gold Colored Coating of TiO2 thin film on Nickel-Silver by Sol-Gel Process (양백에 코팅된 비정질 TiO2 박막의 특성에 관한 연구)

  • Lim, Yongmu;Kim, Sangmoon;Shim, Moonsik;Jang, Heejin;Shin, Jongyoon;Hwang, Kyuseog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.51-56
    • /
    • 1999
  • $TiO_2$ thin films were spin coated on commercial Nickel-Silver with 2%Ti-naphthanate toluene solution by sol-gel process. The thin films were heat-treated at $500^{\circ}C$ for 2min and then decorative-protective coating was obtained. The conditions for gold colored coating, and the morphology, microstructure and color of the coating surface were have been characterized by Optical microscope, Photospectrometer and XRD. The heating temperature of colored-$TiO_2$ coating was $500^{\circ}C$ and was preferable. The average thickness of 1 time coating was $0.24{\mu}m$ and the total thickness increased linearly as a function of the coating time. The color of amorphous colored-$TiO_2$ coating was changed from gold to dark redish gold with coating time. 'L' as lightness and 'b' were decreased to red, but 'a' was decreased to blue after increase with coating time.

  • PDF

Properties of Cenosphere Particle in the Fly Ash Generated from the Pulverized Coal Power Plant (석탄화력 발전소에서 생성되는 석탄회에서 Cenosphere 입자의 특성에 관한 연구)

  • Lee, Jung-Eun;Lee, Jae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1881-1891
    • /
    • 2000
  • Cenosphere particles of different fly ash formed at the pulverized coal power plant were hollow sphere or filled with small particles inside solid particles. And size was relatively larger than other fly ash particles as well as specific gravity was small to suspend in the water. In this paper, it was demonstrated to contain a variety of morphological particle type, and the physical and chemical properties related to the cenosphere and fly ash particles. Furthermore it was estimated the possibility to reuse the cenosphere particles on the base of cenosphere properties. Cenosphere formation resulted from melting of mineral inclusion in coal, and then gas generation inside the molten droplet. As the aluminosilicate particle was progressively heated, a molten surface layer developed around the solid core. Further heating leaded to cause the formation of fine particles at the core. The mass median diameter(MMD) of cenosphere particles was $123.11{\mu}m$ and the range of size distribution was $100{\sim}200{\mu}m$ with single modal. It was represented that specific density was $0.67g/cm^3$ fineness was $1135g/cm^3$. The chemical components of cenosphere were similar to other fly ash including $SiO_2$, $Al_2O_3$, but the amount of the chemical component was different respectively. In the case of fly ash, $SiO_2$ concentration was 54.75%, and $Al_2O_3$ concentration was 21.96%, so this two components was found in 76.71% of the total concentration. But in the case of cenosphere, it was represented that $SiO_2$ concentration was 59.17% and $Al_2O_3$ concentration was 30.16%, so this two components was found in 89.33% of the total concentration. Glassy component formed by the aluminosilicate was high in the cenosphere, so that it was suitable to use insulating heat material.

  • PDF

Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement (아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가)

  • So, Kyung-Rock;Lee, Hyun-Jong;Baek, Jong-Eun;Lee, Sang-Yum
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.19-28
    • /
    • 2011
  • This study developed a solar radiation reflection pavement, so called a cool pavement, to lessen the urban heat island effect by coating a pavement surface with acrylic resins mixed with light-colored pigments. From a laboratory test, simulating solar heating process in pavements, the cool pavement reduced more than $12^{\circ}C$ of pavement temperature at $60^{\circ}C$ compared to a control porous pavement. With the increase of the mixing ratio of the pigments to acrylic resins, the temperature reduction effect increased, but its workability became worse due to higher viscosity. As a result, an appropriate mixing ratio was determined as 15%. The cool pavement had better durability than the control pavement: One quarter of Catabro loss and twofold dynamic stability. Its adhesion was also higher enough not to be debonded under traffic loading. In-situ noise and friction tests conducted in two field sites showed that the cool pavement reduced its noise level by 3.7dB in average and increased its friction level by 30% compared to the control pavement. The permeability of the cool pavement was little lower than the control pavement, but higher enough to satisfy the minimum requirement for porous pavements.

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

Mechanical and Electrical Reliability of Silver Nanowire Film on Flexible Substrate (유연기판 위에 제작된 Silver Nanowire 필름의 기계 및 전기적 신뢰성 연구)

  • Lee, Yo Seb;Lee, Won Jae;Park, Jin Yeong;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.93-99
    • /
    • 2016
  • In this paper, we investigated the mechanical and electrical reliability of silver nanowire (AgNW) films. In particular, the durability and reliability of AgNW films were studied when the AgNW film was subjected to the bending deformation under current flow. The electrical durability of AgNW was evaluated by observing changes in heat generation and current density occurring in AgNW through voltage and current tests. The AgNW film showed a constant resistance change up to a bending radius of 2 mm and 200,000 cycles in the bending fatigue tests. The over-coating layer has an effect of improving the durability of the AgNW film. In the case of AgNW with the over-coating layer, heat was uniformly dissipated on the surface of AgNW film, whereas in the case of AgNW film without the over-coating layer, heat was generated locally. In the bending test under the current flow, the current density of the AgNW film was continuously decreased up to 52.4%. During bending, the AgNW was deformed due to mechanical deformation such as tensile, bending and sliding of the AgNW, consequently contact resistance of the AgNW was increased, leading to a electrical breakdown of AgNW by Joule heating. It was found that the application of the over-coating layer can improve the electrical and mechanical reliability of the AgNW film.

Antioxidative and Nitrite Scavenging Activities of Polygonatum odoratum Root Extracts with Different Steaming and Roasting Conditions (둥굴레 근경의 증자 및 볶음조건에 따른 추출물의 항산화성 및 아질산염 소거능 변화)

  • Kim Kyung-Tae;Kim Jung-Ok;Lee Gee-Dong;Kwon Joong-Ho
    • Food Science and Preservation
    • /
    • v.12 no.2
    • /
    • pp.166-172
    • /
    • 2005
  • Response surface methodology (RSM) was applied to monitor the effects of steaming and roasting conditions of Polygonatum odoratum roots an total phenolics content, electron donating ability (EDA) and nitrite-scavenging ability (NSA) of the extract. In steaming and roasting processes based on the central composite design. with variations in steaming time $(60\~180\;min)$, roasting temperature $(110\~150\;min)$ and roasting time $(10\~50\;min)$, coefficients of determinations $(R^2)$ were 0.9356 (p<0.01) in total phenolics, 0.9578 (p<0.01) in EDA and 0.9436 (p<0.01) in NSA (pH 3.0). The maximum value of total phenolics was $2847.67\;mg\%$ at 135.59 min of steaming time, $143.84^{\circ}C$ of roasting temperature and 43.47 min of roasting time. The maximum value of EDA was $75.00\%$ in 108.98 min, $135.56^{\circ}C$ and 48.86 min. The maximum value of NSA (pH 3.0) was $87.38\%$ in 162.80 min, $143.88^{\circ}C$ and 31.97 min, respectively. Total phenolics content of the extract was influenced by heating conditions in the order of roasting temperature, steaming time and roasting time. While EDA and NSA were appreciably influenced by roasting time, followed by roasting temperature and steaming time.