• 제목/요약/키워드: surface grafting

검색결과 190건 처리시간 0.029초

The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study

  • Kim, Min-Joong;Yun, Pil-Young;Chang, Na-Hee;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.10.1-10.9
    • /
    • 2020
  • Background: The aim of this study was to evaluate the long-term clinical stability of implants with acid-etched surfaces sandblasted with alumina using retrospective analyses of the survival rate, success rate, primary and secondary stability, complications, and marginal bone loss of the implants. Methods: Patients who had implants placed (TS III SA, SS II SA, SS III SA, and U III SA) with SA surfaces from Osstem (Osstem Implant Co., Busan, Korea) at the Seoul National University Bundang Hospital, from January 2008 to December 2010 were selected for the study. Patients' medical records and radiographs (panorama, periapical view) were retrospectively analyzed to investigate sex, age, location of implantation, diameter, and length of the implants, initial and secondary stability, presence of bone grafting, types of bone grafting and membranes, early and delayed complications, marginal bone loss, and implant survival rate. Results: Ninety-six implants were placed in 45 patients. Five implants were removed during the follow-up period for a total survival rate of 94.8%. There were 14 cases of complications, including 6 cases of early complications and 8 cases of delayed complications. All five implants that failed to survive were included in the early complications. The survival of implants was significantly associated with the occurrence of complications and the absorption of bone greater than 1 mm within 1 year after prosthetic completion. In addition, the absorption of bone greater than 1 mm within 1 year after prosthetic completion was significantly associated with the occurrence of complications, primary stability, and implant placement method. Five cases that failed to survive were all included in the early complications criteria such as infection, failure of initial osseointegration, and early exposure of the fixture. Conclusions: Of the 96 cases, 5 implants failed resulting in a 94.8% survival rate. The failed implants were all cases of early complications such as infection, failure of initial osseointegration, and early exposure of the fixtures. Periimplantitis was mostly addressed through conservative and/or surgical treatment and resulted in very low prosthetic complications. Therefore, if preventive measures are taken to minimize initial complications, the results can be very stable.

단백질 흡착성을 갖는 막 크로마토그래피용 재생 셀룰로오스 기반 음이온 교환 다공성 분리막의 제조 (Preparation of Protein Adsorptive Anion Exchange Membrane Based on Porous Regenerated Cellulose Support for Membrane Chromatography Application)

  • 서정현;이홍태;김태경;조영훈;오택근;박호식
    • 멤브레인
    • /
    • 제32권5호
    • /
    • pp.348-356
    • /
    • 2022
  • 바이오산업의 발전으로 의약품, 식품 등의 생산 과정의 분리/정제 공정에 사용되어 왔던 기존의 컬럼 크로마토그래피를 대체하여 더 높은 처리효율을 갖는 막 크로마토그래피가 부상하고 있다. 본 연구에서는 서로 다른 기공 크기의 두 가지 상용 셀룰로오스 아세테이트(Cellulose acetate, CA) 분리막을 탈아세틸화 과정을 통해, 리간드의 개질이 용이한 다공성 재생 셀룰로오스 지지체를(Regenerated cellulose, RC) 제조하였다. 음이온 교환능을 부여하고자 grafting을 수행하였으며, 구체적으로는 UV 중합법을 통해 4차 암모늄을 포함하는 음이온 교환 리간드(MAPTAC)를 부착하여 음이온 교환용 흡착막을 제조하였다. 단백질 흡착 용량은 정적 흡착 용량(Static binding capacity, SBC)시험을 통해 총 단백질 흡착 용량을 측정했고, 동적 흡착 용량(Dynamic binding capacity, DBC)을 측정하여 상용막과 비교 평가하였다. 성능 평가 결과 단백질 흡착량은 넓은 표면적에 의해 리간드 밀도가 높은, 기공 크기가 작은 순서로 높게 측정되었고, 상용 CA분리막을 탈아세틸화하고 리간드를 부착시킨 분리막(RC 0.8 + MAPTAC 43.69 mg/ml, RC 3.0 + MAPTAC 36.33 mg/ml)이 상용 막 크로마토그래피 제품(28.38 mg/ml) 대비 높은 흡착 용량을 보였다.

수종의 골이식재를 이용한 성견의 임플란트 주위 3면 골내낭의 조직학적 관찰 (Histologic findings of three-wall intrabony defects around dental implants using different grafting materials in beagle dogs)

  • 문희일;문상권;김창성;;이용근;조규성;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.439-455
    • /
    • 2003
  • 연구목적 : SLA surface dental implant 주위의 3면 골내낭에서 xenogeneic demineralized bone matric putty, porous ${\beta}$-tri-calcium phosphate, 새로이 개발된 non-crystalline calcium phosphate glass를 사용한 치료를 조직학적으로 비교 평가하기 위한 것이다. 연구방법 : 실험동물로는 15개월에서 18개월 사이의 12kg에서 15kg 정도되는 성견을 사용하였다. 20개의 SLA surface implant가 사용되었으며, 성견 하악의 양측에 각각 2개씩 사용되었다. 임플란트 식립전에, 각각의 임플란트 근심면에 straight fissure bur를 이용하여 표준화된 3면 골내앙(근원심 5mm ${\times}$협설 3mm ${\times}$깊이 3mm)을 형성하였다. 형성된 골 결손부에는 demineralized bone matrix putty, porous ${\beta}$-tri-calcium phosphate, non-crystalline calcium phosphate glass를 넣은 것을 각각 실험군으로, 이식재를 넣지 않은 것을 대조군으로 사용하였다. 8주 후에 실험 동물을 희생시키고 조직학적 관찰을 하였다. 결과 : 조직학적 소견상 임플란트 주위에 급성 염증 소견은 보이지 않았으며, non-crystalline calcium phosphate glass은 매우 적은량의 신생골을, ${\beta}$-TCP을 이용한 골내낭에서는 약간의 기저부에서 유래된 신생골이 관찰된다. ${\beta}$-TCP granules 가운데로 상당량의 측면의 골에서 유래된 신생골 형성이 보인다. xenogeneic DBM putty에서는 많은 량의 신생골이 기저부에 형성된 것을 볼수 있으나 대조군과의 차이는 크지 않다. 이식재의 종류와 상관없이 흡수되지 않은 이식재를 임플란트 주위에서 관찰할 수 있었다. 골내낭 안의 이식재들은 모두 connective tissue로 둘러 싸여 있었다. 모든 실험군에서 이식재에서 기인한 신생골 형성과 임플란트 표면에 신생 골유착의 조직학적 증거는 발견되지 않았다.

UV 조사에 의한 아민화 Poly(ethersulfone) 이온교환막의 제조 및 특성 (Preparation and Properties of Aminated Poly(ethersulfone) Ion-Exchange Membrane by UV Irradiation Method)

  • 최국종;황의환;이영우;황택성
    • 폴리머
    • /
    • 제32권1호
    • /
    • pp.70-76
    • /
    • 2008
  • UV 조사방법으로 poly(ethersulfone) PES 막에 1,2,3,4-butanetetracarboxylic acid(BTCA)를 그래프트 공중합하고, 이를 아민화시켜 PES 음이온교환막을 합성하였으며, 이들의 구조 및 특성을 확인하였다. PES 음이온교환막의 그래프트율과 아민화율은 반응 시간에 따라 증가하였으며, 80분에서 최대 134%, 1.20 mmol/g이었다. PES 음이온교환막의 초기 열분해온도는 $400^{\circ}C$로 표면개질반응이 진행됨에 따라 감소하였다. PES 음이온교환막의 접촉각은 아민화율이 증가함에 따라 $68.1^{\circ}{\sim}40.2^{\circ}$로 감소하였으며, 함수율과 이온교환용량은 UV 조사시간이 증가함에 따라 80분까지 선형적으로 증가하였다. 또한 막의 평균 기공의 크기와 비표면적은 PES 막, PES-g-BTCA 공중합체막, PES 음이온교환막의 순이었으며, 평균기공 크기값은 624.8, 359.7, 138.5 ${\AA}$, 비표면적은 10.1, 9.7, 1.7 $m^2/g$이었다.

CuO Nanoparticles/polyaniline/CNT fiber 유연 전극 기반의 H2O2 검출용 비효소적 전기화학 센서 (A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode)

  • 송민정
    • Korean Chemical Engineering Research
    • /
    • 제61권2호
    • /
    • pp.196-201
    • /
    • 2023
  • 우리는 금속 산화물 CuO nanoparticles (CuO NPs)과 전도성 고분자 Polyaniline (PANI)가 접목된 CNT fiber 유연 전극(CuO NPs/PANI/CNT fiber 전극)을 개발하여 H2O2 검출용 비효소적 전기화학센서에 적용하였다. CNT fiber 표면 위에 PANI와 CuO NPs을 전기화학적 합성/증착을 통해 제작된 CuO NPs/PANI/CNT fiber 전극은 주사전자 현미경(SEM)과 에너지분산형 분광분석법(EDS)을 통해 표면 분석이 수행되었으며, 순환전압 전류법(CV)과 전기화학 임피던스법(EIS), 시간대전류법(CA)을 이용하여 전기화학적 특성 및 H2O2 센싱 성능이 분석되었다. CuO NPs/PANI/CNT fiber 전극은 대조군인 bare CNT fiber 전극과 비교하여 약 4.78배의 유효 표면적 증가를 보였으며, 약 8.33배의 전자 전달 저항(Ret) 감소로 인한 우수한 전기 전도성 및 효율적인 전자전달 등의 전기화학적 특성을 나타냈다. 이런 향상된 전극 특성은 CuO NPs와 PANI의 접목을 통한 시너지 효과에 기인한 것으로, 결과적으로 H2O2 검출에 대한 센싱 성능이 개선되었다.

임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료 (Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption)

  • 최유성
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

Amino Acid-Based Material for the Complementary Therapy of Decubitus Ulcers

  • Nogueira, Frederico;Gouveia, Isabel C.
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권4호
    • /
    • pp.747-758
    • /
    • 2017
  • Chronic wounds, pressure sores, lesions, and infections of microbial origin in bedridden, paralyzed, or malnutrition patients remain the object of study of many researchers. A variety of factors behind the development of these disorders are related to the patient's immune system, making it unable to respond effectively to the treatment of the wound. These factors can be properly controlled, giving particular importance to the ethiology and stage of the wound, as well as the time periods corresponding to the replacement of the dressings. The present research reports a novel foam/soft material, ${{\small}L}$-Cys-g-PCL, with an application for decubitus/pressure ulcers, especially for wounds with a difficult healing process due to infections and constant oxidation of the soft tissues. During this work, the interactions between S. aureus and ${{\small}L}$-Cys-g-PCL foam were studied under conditions that simulate decubitus ulcers; namely, pH and exudate. The effects of duration of grafting (1 or 8 h) and pH (7.0 and 8.9) on wettability, surface energy, swelling, and porosity were also evaluated. Results showed an effective microbicidal activity exhibiting an inhibition ratio of 99.73% against S. aureus. This new ${{\small}L}$-Cys-g-PCL soft material showed saftey to contact skin, ability to be shaped to fill in sunken holes (craters) - pressure ulcers stage III - and to act as a smart material responsive to pH, which can be tailored to develop better swelling properties at alkaline pH where exudates are normally higher, so as to address exudate self-cleaning and prevention of desiccation.

악골 낭종의 적출술 후 골재생에 대한 파노라마 촬영과 컴퓨터 단층촬영의 비교 분석 (Spontaneous bone regeneration after enucleation of jaw cysts: a comparative study of panoramic radiography and computed tomography)

  • 김택성;이재훈
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.100-107
    • /
    • 2010
  • Introduction: A cyst is a closed pathologic sac containing fluid or semi-solid material in central region. The most common conventional treatment for a cyst is enucleation. It was reported that spontaneous bone healing could be accomplished without bone grafting. We are trying to evaluate bone reconstruction ability by analyzing panorama radiograph and computed tomography (CT) scan with retrograde studying after cyst enucleation. In this way we are estimating critical size defect for spontaneous healing without bone graft. Materials and Methods: The study comprised of 45 patients who were diagnosed as cysts and implemented enucleation treatment without bone graft. After radiograph photo taking ante and post surgery for 6, 12, 18, 24 months, the healing surface and volumetric changes were calculated. Results: 1. Spontaneous bone healing was accomplished clinically satisfying 12 months later after surgery. But analyzing CT scan, defect volume changes indicate 79.24% which imply incomplete bone healing of defect area. 2. Comparing volume changes of defect area of CT scan, there are statistical significance between under $5,000mm^{3}$ and over $5,000mm^{3}$. The defect volume of $5,000mm^{3}$ shows $2.79{\times}1.91$cm in panoramic view. Conclusion: Bone defects, which are determined by a healed section using a panoramic view, compared to CT scans which do not show up. Also we can estimate the critical size of defects for complete healing.

역행성 임플란트 근단병소 주위염(Retrograde Peri-implantitis) 치료의 7년 관찰 (Treatment of retrograde peri-implantitis: seven-year follow-up study)

  • 이주연
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.259-264
    • /
    • 2014
  • 역행성 임플란트 근단병소 주위염은 임상증상을 동반한 근단부의 방사선 투과성 병소로 정의되며 임플란트 식립부위 또는 인접한 치아의 잔존하고 있는 감염에서 유래한 세균감염, 골 삭제시의 열 발생 등의 다양한 원인에 의해 야기될 수 있고, 다양한 치료방법으로 임플란트를 제거하지 않고 유지할 수 있는 증례들이 보고되고 있다. 본 증례에서는 근관 치료 실패로 발치한 상악 우측 제2소구치 부위에 식립한 임플란트에서 발생한 역행성 임플란트 근단병소 주위염을 표면의 detoxification과 차폐막과 골이식재를 동반한 골유도재생술로 해결하여 기능을 회복하였으며, 7년간 장기적으로 안정적으로 유지되고 있는 증례에 대해 보고하고자 한다.

폴리비닐 부티랄에 붙힌 지르코늄 알콕시드 졸을 사용한 전기방사에서 지르코니아 나노섬유 제조와 광발광 (Photoluminescence and Fabrication of Zirconia Nanofibers from Electrospinning an Alkoxide Sol Templated on a Polyvinyl Butyral)

  • 고태경;한규석;임태균;오성규;한상환
    • 한국세라믹학회지
    • /
    • 제47권4호
    • /
    • pp.343-352
    • /
    • 2010
  • A zirconia gel/polymer hybrid nanofiber was produced in a nonwoven fabric mode by electrospinning a sol derived from hydrolysis of zirconium butoxide with a polyvinyl butyral. Results indicated that the hydroxyl groups on the vinyl alcohol units in the backbone of the polymer were involved in the hydrolysis as well as grafting the hydrolyzed zirconium butoxide. In addition, use of acetic acid as a catalyst resulted in further hydrolysis and condensation in the sol, which led to the growth of -Zr-O-Zr- networks among the polymer chains. These networks gradually transformed into a crystalline zirconia structure upon heating. The as-spun fiber was smooth but partially wrinkled on the surface. The average fiber diameter was $690{\pm}110\;nm$. The fiber exhibited a strong but broad blue photoluminescence with its maximum intensity at a wavelength of ~410 nm at room temperature. When the fiber was heat-treated at $400^{\circ}C$, the fiber diameter shrunk to $250{\pm}60\;nm$. Nanocrystals which belonged to a tetragonal zirconia phase and were ~5 nm in size appeared. A strong white photoluminescence was observed in this fiber. This suggests that oxygen or carbon defects associated with the formation of the nanocrystals play a role in generating the photoluminescence. Further heating to $800^{\circ}C$ resulted in a monoclinic phase beginning to form In the heat-treated fibers, coloring occurred but varied depending on the heating temperature. Crystallization, coloring, and phase transition to the monoclinic structure influenced the photoluminescence. At $600^{\circ}C$, the fiber appeared to be fully crystallized to a tetragonal zirconia phase.