• Title/Summary/Keyword: surface exposure

Search Result 1,374, Processing Time 0.035 seconds

SCANNING ELECTRON-MICROSCOPIC STUDY OF THE EFFECT OF CITRIC ACID AND TETRACYCLINE HCL CONDITIONING ON DISEASED ROOT SURFACE (구연산과 염산트라싸이클린이 치근면 탈회에 미치는 효과에 대한 주사전자현미경적 연구)

  • Kim, Young;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.24-34
    • /
    • 1995
  • The purpose of this study was to compare effects of demineralization of citric acid and tetracycline HCI on periodontally involved root surface. Twelve periodontally involved single rooted teeth were used. After scaling and root planing, root conditioning with citric acid and tetracycline HCI were carried and the teeth were processed scanning electron microscopic observation.The results were as follows: The scaled root surface was covered by much debris and calculus. The effect of demineralization of citric acid and tetracycline HCI was more reduced on scaling group than root planing group, because of hypermineralization of cementum surface and demineralization effect on root surface of tetracycline HCI showed tendency to reduction. The root planed group displayed more smooth root surface than scaling group, the surface was covered by smear layer, thus no exposure of dentinal tubule opening and collagen fiber, especially after root planing, citric acid and tetracycline HCl treated group showed exposure of dentinal tubule and collagen fiber, thus it was thought that new connective tissue attachment could be acquired.

  • PDF

Investigation of Surface Degradation in Silicone Rubber Due to Corona Exposure (코로나 방전에 노출된 고분자 애자용 실리콘 고무의 표면열화)

  • Hong, Joo-Il;Huh, Chang-Su;Lee, Ki-Taek;Hwang, Sun-Mook;Youn, Bok-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1068-1078
    • /
    • 2004
  • In this paper we investigated the characteristics of surface degradation in silicone rubber due to corona exposure and recovery mechanism. It was shown that surface free energy was 22.42 mJ/$m^2$ on initial sample but surface free energy was approximately increased to 71.14 mJ/$m^2$ after 45 minutes. However, surface free energy on silicone rubber after corona discharge treatment was completely recovered within a short time due to diffusion of low molecular weight(LMW) silicone fluid. It was shown that corona discharge insured the increase of diffusible LMW chains, which could lead to recover the surface hydrophobicity. 200~370 g/mol distribution of LMW silicone fluid which was extracted by solvent-extraction with gel permeation chromatography (GPC) was contributed to recovery. The surface degradation characteristics on silicone rubbers and the recovery mechanism based on our results were discussed.

Liquid Crystal Aligning Capabilities on the Photopolymer Based Maleimide (Maleimide계 폴리머를 이용한 액정배향특성)

  • Lee, Yun-Gun;Hwang, Jeoung-Yeon;Seo, Dae-Shik;Kim, Jun-Young;Lee, Jae-Ho;Kim, Tae-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.358-361
    • /
    • 2001
  • A new photoalignment material PMI5CA, poly{N-(phenyl)maleimide-co-3-[4-(pentyloxy) cinnamate]propyl-2-hydroxy-1-methacrylate}, was synthesized and the electra-optical (EO) characteristics in the vertical-aligned (VA) liquid crystal display (LCD) photo-aligned on the photopolymer surface were studied. Excellent voltage-transmittance(V-T) characteristics in the VA-LCD photoaligned with polarized UV exposure of oblique direction on the pohotopolymer surfaces for 1 min can be achieved. The transmittance of the VA-LCD photoaligned on the photopolymer surface decreased with increasing UV exposure time. We suggest that the decrease of transmittance in the VA-LCD photoaligned on the photopolymer surface is attributed to the dissociation of the ester linkage in the photodimerized cinnamate structure with increasing UV exposure time

  • PDF

Liquid Crystal Alignment Effect on the Inorganic Thin Film by Sputtering and using Ultraviolet Exposure Mothod

  • Hwang, Jeoung-Yeon;Kang, Hyung-Ku;Seo, Dae-Shik;Oh, Byeong-Yun;Ham, Moon-Ho;Myoungr, Jae-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.460-463
    • /
    • 2005
  • We studied the nematic liquid crystal (NLC) alignment capability by the Ultraviolet (UV) alignment method on a a-C:H thin -film , and investigated electro-optical performances of the UV aligned twisted nematic (TN)- liquid crystal display (LCD) with the UV exposure on a-C:H thin film surface. A good LC alignment by UV irradiation on a a-C:H thin -film surface was achieved. Monodomain alignment of the UV aligned TN-LCD can be observed. The good electro-optical (EO)characteristics of the UV aligned TN-LCD was observed with oblique UV exposure on the a-C:H thin film surface for 1min.

  • PDF

STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS (DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구)

  • Kown, O-Teak;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

The Influence of Weathering Conditions on the Outer Membrane of Biogas with Plasticized PVC : A Study using Non-destructive Tests

  • Kim, Changhwan;Ki, Wootae;Kim, SangMyung;Shin, Jinyong
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • The biogas holder is composed of an outer membrane and an inner membrane which are subject to outdoor exposure and gas exposure respectively. The influence of weathering conditions on the photo-degradation of a biogas holder was investigated. Tests were performed under three different methods - outdoor exposure tests (Seosan, Arizona), accelerated tests (Xenon-are lamp) with the outer-membrane of biogas. Moreover, the changes in the aging process were monitored using color difference, gloss, the contact angle and an optical microscope. Changes in physical properties, such as decrease reduction in gloss, decrease in the contact angle, increase in color difference were observed in the aging process. The comparison between membrane 3B, 4B and membrane 5B under xenon-arc were discussed. Membrane 5B was very sensitive to ultraviolet (UV) ray. There were many difficulties in the outdoor exposure test due to acid rain, dust, and stain resistance.

EO performance of TN cell on the inorganic films surface using DuoPIGatron ion source on NDLC thin film (무기박막표면에 DuoPIGatron 이온소스를 이용한 TN-LCD 셀의 전기광학 특성)

  • Kim, Byoung-Yong;Hwang, Jeoung-Yeon;Kim, Sang-Hun;Han, Jung-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.432-433
    • /
    • 2006
  • Electro-optical (EO) characteristics of twisted nematic (TN) - liquid crystal display (LCD) on the NDLC thin film using obliquely ion beam (IB) exposure as new ion beam (IB) type system (DuoPIGatrion ion source). A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the NDLC thin film was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-cell on polyimide surface ; the stable VT curve in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained. and the fast response time in the ion-beam-aligned TN cell on the NDLC thin film with ion beam exposure using new type IB equipment was obtained.

  • PDF

Atmospheric Corrosion and Surface Appearance of Galvalume Steel following Outdoor Exposure for 36 Months: A Korean Study (36개월간 국내 옥외폭로시험에 따른 갈바륨 강판의 대기부식거동 및 표면외관 변화)

  • Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.326-336
    • /
    • 2020
  • Galvalume steel (GL) is widely used in marine and industrial environments. It is characterized by better corrosion resistance than carbon steel. However, corrosion and economic losses may occur as the usage time is increased. Therefore, in this study, an outdoor exposure test of GL for 36 months was conducted across six regions of Korea. Parameters such as corrosion rate, chrominance (color, chroma, and brightness), glossiness, and surface appearance were analyzed. The results showed no significant change in appearance, and the initial corrosion rate was large, but a tendency to decrease with time was observed. Increased outdoor exposure time led to increase in the level of corrosion products. In the case of coastal areas where S, Cl, and other elements were detected, a relatively high decrease in Zn content was observed. Al forms a protective oxide film and exists in the coating layer, but Zn dissolves due to its chemical activity and low potential.

Flexural Performance of RC Beams Strengthened with NSM-GFRP Exposed to High Temperature (GFRP 표면매립공법으로 보강된 RC보의 고온노출 후 휨 성능)

  • Kim, Hee-Seung;Lee, Hye-Hak;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.35-42
    • /
    • 2018
  • This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substrate and GFRP plate were used; flame resisting epoxy and filling mortar. Four RC beam specimens were made and two of them were exposed to fire according to real scale fire curve proposed KS F 2257. After the fire exposure test, flexural test were performed to investigate the flexural performance of concrete beams including strength and deformation. From the test results, it was found that the beam retrofitted by NSM-GFRP presented higher flexural strength than that of the beam without retrofit, which indicates NSM-GFRP retrofit technologies is effective to maintain flexural strength even after fire exposure. In addition, the specimens grouted by epoxy showed good performance in strength but bad performance in ductility.

Effect of 5%Mg alloying in Al wire on corrosion resistance performance in saline solution (식염수에서 내식성 성능에 대한 Al 와이어의 5%Mg 합금 효과)

  • Singh, Jitendra Kumar;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.93-94
    • /
    • 2022
  • The presence of chloride (Cl-) ions in environments causes localized corrosion resulting decrease the durability of the structures. In this study, 5% Mg containing Al alloys (Al-5Mg) wire used vis-à-vis compared its corrosion resistance with pure Al in 3.5wt.% NaCl solution with exposure periods. Initially both wires exhibited identical open circuit potential (OCP) attributed to the presence of native oxide film on the surface but with the exposure periods it shifted towards active direction owing to the dissolution of oxide film. The pure Al continuously shifted the OCP towards active direction while Al-5Mg shows stabilization of OCP after 8 days of exposure. The OCP of Al-5Mg is slightly higher compared to pure Al wire owing to the activeness of Mg. The total impedance of the Al-5Mg alloy is almost three times greater than pure Al with exposure periods in 3.5 wt.% NaCl solution. It might be formation of Al-Mg LDH (layered double hydroxide) thin film onto the surface.

  • PDF