• Title/Summary/Keyword: surface exposure

Search Result 1,374, Processing Time 0.035 seconds

Exposure Assessment and Management of Ionizing Radiation (전리방사선 노출과 관리)

  • Chung, Eun-Kyo;Kim, Kab-Bae;Song, Se-Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • Objectives: To investigate safety and health management, conditions in factories or facilities handling radiation-generating devices and radioactive isotopes were reviewed in terms of regulations of radiation safety control in Korea. Radiation exposure levels generated at those facilities were directly measured and evaluated for establishing an effective safety and health management plan. Methods: Government organizations with laws and systems of radiation safety and health were investigated and compared. There are three laws governing radiation-related employment such as occupational safety and health acts, nuclear safety acts, and medical service acts. We inspected 12 workplaces as research objects:four workplaces that manufacture and assemble semiconductor devices, three non-destructive inspection workplaces that perform inspections on radiation penetration, and five workplaces in textile and tire manufacturing. Monitoring of radiation exposure was performed through two methods. Spatial and surface monitoring using real-time radiation instruments was performed on each site handling radiation generating devices and radioactive isotopes in order to identify radiation leakage. Results: According to the occupational safety and health act, there is no legal obligation to measure ionizing radiation and set dose limits. This can cause confusion in the application of the laws, because the scopes and contents are different from each other. Surface dose rates in radiation generating devices such as implanters, thickness gages and accelerators, which were registered according to nuclear safety acts, using surveymeters, and seven of 36 facilities(19.4%) exceeded the international standards for surface radiation dose of $10{\mu}Sv/hr$. Conclusions: The results showed that occupational health and safety acts require a separate provision for measuring and assessing the radiation exposure of workers performing radiation work. Like noise, ionizing radiation will also periodically be controlled by including it in the object factors of work-environment measurement.

Numerical Analysis for Cooling Condition of a Lamp House in the Exposure Device by Response Surface Methodology (반응표면분석법을 이용하여 노광기 램프하우스의 냉각조건 수치해석)

  • Kim, Youngshin;Jeon, Euysik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1265-1271
    • /
    • 2014
  • The lamp cooling system of the exposure has effect on the exposure efficiency and device lifetime. In this paper, we performed the numerical analysis about the thermal flow in the lamp housing of the exposure apparatus for the cooling air inflow rate. We set up the velocity of cooling air of side and bottom as the independent variables because cooling performance of the lamp housing is affected by the velocity of the cooling air side and bottom. The cooling state of lamp housing depend on three dependent variables; the temperature at top mirror and exhaust gas, ellipsoidal mirror. Response surface methodology was used in order to establish the efficient cooling analysis plan. The regression equation predicting the variables temperature of lamp housing according to the cooling air velocity were drawn. The velocity of cooling air to reach the optimum temperature of the lamp housing were derived.

Occupational Exposure during Intraperitoneal Pressurized Aerosol Chemotherapy Using Doxorubicin in a Pig Model

  • Wongeon Jung;Mijin Park;Soo Jin Park;Eun Ji Lee;Hee Seung Kim;Sun Ho Chung;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.237-242
    • /
    • 2023
  • Background: This study evaluated occupational exposure levels of doxorubicin in healthcare workers performing rotational intraperitoneal pressurized aerosol chemotherapy (PIPAC) procedures. Methods: All samples were collected during PIPAC procedures applying doxorubicin to an experimental animal model (pigs). All procedures were applied to seven pigs, each for approximately 44 min. Surface samples (n = 51) were obtained from substances contaminating the PIPAC devices, surrounding objects, and protective equipment. Airborne samples were also collected around the operating table (n = 39). All samples were analyzed using ultra-high performance liquid chromatography-mass spectrometry. Results: Among the surface samples, doxorubicin was detected in only five samples (9.8%) that were directly exposed to antineoplastic drug aerosols in the abdominal cavity originating from PIPAC devices. The telescopes showed concentrations of 0.48-5.44 ng/cm2 and the trocar showed 0.98 ng/cm2 in the region where the spraying nozzles were inserted. The syringe line connector showed a maximum concentration of 181.07 ng/cm2, following a leakage. Contamination was not detected on the surgeons' gloves or shoes. Objects surrounding the operating table, including tables, operating lights, entrance doors, and trocar holders, were found to be uncontaminated. All air samples collected at locations where healthcare workers performed procedures were found to be uncontaminated. Conclusions: Most air and surface samples were uncontaminated or showed very low doxorubicin concentrations during PIPAC procedures. However, there remains a potential for leakage, in which case dermal exposure may occur. Safety protocols related to leakage accidents, selection of appropriate protective equipment, and the use of disposable devices are necessary to prevent occupational exposure.

Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

  • Wilson Hrangkhawl;Winniecia Dkhar;T.S. Madhavan;S. Sharath;R. Vineetha;Yogesh Chhaparwal
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.15-19
    • /
    • 2023
  • Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to estimate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan. Materials and Methods: The average scattered radiation dose for i-CAT 17-19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instruments), placed at the patient's neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-O-Meter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck. Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491±78.486 µGy for 0.25 mm voxel and 26.9 seconds, and 153.670±74.041 µGy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259±10.691 µGy. Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shielding to the thyroid gland.

Adsorption of Atomic Hydrogen on ZnO Single Crystal Surfaces: A Study on the Impact of Surface Structure

  • Roy, Probir Chandra;Motin, Abdul;Kim, Chang-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.216-216
    • /
    • 2012
  • The interaction of hydrogen with ZnO single crystal surfaces, ZnO (0001), ZnO (000-1), and ZnO (10-10) has been investigated using temperature programmed desorption (TPD) and X-ray photoelectron Spectroscopy (XPS) techniques. When the ZnO single crystal surfaces are exposed to atomic hydrogen at 200 K, all three surfaces show hydrogen desorption at 450 K. ZnO (0001) surface shows hydrogen desorption feature at ~260 K as the hydrogen exposure is increased. The ZnO (10-10) surface shows low-temperature desorption feature first and the high-temperature desorption feature appears as the hydrogen exposure increases. The ZnO (000-1) surface does not show any lower temperature hydrogen desorption. We will report the adsorption configuration of hydrogen atoms on ZnO single crystal surfaces with different surfaces structures.

  • PDF

Electro-optical characteristics of TN-LCD on a Polyimide Surface Exposed to an Ion Beam (고분자 막을 이용한 이온빔 배향 TN-LCD의 전기광학특성)

  • Kim, Sang-Hoon;Hwang, Jeoung-Yeon;Kang, Hyung-Ku;Bae, Yu-Han;Lee, Whee-Won;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.271-272
    • /
    • 2005
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam exposure. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties, and residual DC property of the ion-beam-aligned TN-LCD on polyimide surface.

  • PDF

Investigation of LC Alignment Using Ion-beam and Overcoat Layer (이온빔 에너지와 유기절연막 사용에 의한 액정 배향 연구)

  • Kim, Byoung-Yong;Park, Hong-Gyu;Lee, Kang-Min;Oh, Byeong-Yun;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Kim, Jong-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.370-370
    • /
    • 2007
  • The liquid crystal (LC) aligning capabilities treated on the Organic overcoat thin film surfaces by ion beam irradiation and rubbing method was successfully studied for the first time. The Organic overcoat layer was coated by spin-coating. In order to characterize the LC alignment, the microscope, pretilt angle, thermal stress, and atomic force microscopy (AFM) image was used. The good LC aligning capabilities treated on the Organic overcoat thin film surfaces with ion beam exposure of $45^{\circ}$ above ion beam energy density of 1200 eV can be achieved. But, the alignment of defect of NLC on the Organicovercoat surface at low energy density of 600 eV was measured. The pretilt angle of NLC on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min at energy density of 1800eV was measured about 1.13 degree. But, low pretilt angles of NLC on the Organic overcoat thin film surface with ion beam exposure at energy density of 600, 1200, 2400, and 3000 eV was measured. Also, the pretilt angle of NLC on the rubbed Organic overcoat thin film surfaces was measured about 0.04 degrees. Finally, the good thermal stability of LC alignment on the Organic overcoat thin film surface with ion beam exposure of $45^{\circ}$ for 1 min can be measured.

  • PDF

Histological Response of Kidney, Gill and Hepatopancreas of the Juvenile Olive Flounder, Paralichthys olivaceus after PCBs Exposure (PCBs 노출에 따른 넙치(Paralichthys olivaceus) 치어의 신장, 아가미 및 간췌장의 조직학적 반응)

  • KIM Jae-Won;JEE Jung-Hoon;KANG Ju-Chan;LEE Jung-Sik;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.3
    • /
    • pp.283-289
    • /
    • 2003
  • The effect on kidney, gill, and hepatopancreas of juvenile olive flounder, Paralichthys olivaceus were investigated by histological method under limit concentration of effulent of PCBs for 60 days. The free surface of epithelial cell layer in the renal tubules of kidney showed a strong positive reaction in alcian blue during all exposure period. There were also observed swelling of hemocyte in glomerulus and macrophage. At 60 days after exposure, epithelium of the renal tubules was fused and some of organism $(20\%)$ showed damage of glomerulus and eosinophlic cell in epithelium of the renal tubules. The phenomena such as the activation and increase of the chloride cell, and swelling of hemocyte in the capillary of gill were observed during all exposure period. At 60 days after exposure, swelling of the gill filament and mucous cell appeared in gill and some of organism $(30\%)$ showed swelling of the gill lamellar. Swelling of hemocyte in the capillary of hepatopancreas was observed and the free surface of epithelial layer of the bile duct showed positive reaction in alcian blue during all exposure period. Degenerated zymogen in the pancreas and swelling of the hepatocyte were occurred at 60 days after exposure.

Liquid Crystal Aligning Capabilities on a New Photo-Crosslinkable Polyimide Based Polymer (새로운 광중합 가능한 폴리이미드계 몰리머을 이용한 액정 배향 특성)

  • 황정연;서대식;이상렬;김재형;한은주
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.5
    • /
    • pp.430-434
    • /
    • 2001
  • We synthesized a new photo-crosslinkable polymer (polyimide (PI)-chalcone-biphenyl (BP)) and liquid crystal (LC) aligning capabilities for nematic (N) LC with obliquely polarized UV exposure on a photo-crosslinkable polymer were studied. The high pretilt angle in NLC was obtained by polarized UV exposure on a PI-Chal-BP surface for 3 min. The high pretilt angle generated in NLC is attributed to the biphenyl moieties and the photo-dimerized chalclone group of a photopolymer. Also, good thermal stability of a PI-Chal-BP were obtained by thermogravimetric analysis (TGA) measurement until 450$^{\circ}C$. Finally, good voltage-transmittance curves and response time were observed by UV exposure on a PI-Chal-BP surface for 3min.

  • PDF

Effect of Liquid Crystal Alignment for Photo-Aligned VA-LCD on the Photo-Dimerized Polymer Surface

  • Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.16-19
    • /
    • 2001
  • A photopolymer, copoly (M4Ch-ChMA), copoly ((4-methacryloyloxy) chalcone-cholesteryl methacrylate), was synthesized in this study. The electro-optical (EO) characteristics for the photo-aligned vertical-alignment (VA)-liquid crystal display (LCD) were investigated. Excellent voltage-transmittance curves for the VA-LCD photo-aligned by polarized UV exposure on the copoly (M4Ch-ChMA) surface were observed. The response time for the photo-aligned VA-LCD decrease with increasing UV exposure time. consequently, the photo-dimerized chalcone moiety increased with increasing UV exposure time, which then contributed to a low response time for the VA-LCD photo-aligned.