• 제목/요약/키워드: surface electric resistivity

검색결과 101건 처리시간 0.023초

전하 중첩법을 이용한 표면 저항 또는 체적 저항을 고려한 유전체의 전계 분포해석 (Analysis on Electric Field Distribution of Dielectric Considering Surface or Volume Resistivity By Charge Simulation Method)

  • 민석원;김용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1987-1989
    • /
    • 2000
  • In this paper, electric field distribution of dielectric sphere considering surface or volume resistivity is analysed by the use of rotational symmetric charge simulation method. We applied three methods such as ${\alpha},{\beta}$ modified $\beta$ method to check electric field calculation error. We find f method and modified $\beta$ method are suitable to simulate volume and surface resistivity respectively.

  • PDF

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

Testing of the permeability of concrete box beam with ion transport method in service

  • Wang, Jia Chun
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.461-471
    • /
    • 2015
  • The permeability is the most direct indicator to reflect the durability of concrete, and the testing methods based on external electric field can be used to evaluate concrete permeability rapidly. This study aims to use an experiment method to accurately predict the permeability of concrete box beam during service. The ion migration experiments and concrete surface resistivity are measured to evaluate permeability of five concrete box beams, and the relations between these results in service concrete and electric flux after 6 hours by ASTM C1202 in the laboratory are analyzed. The chloride diffusion coefficient of concrete, concrete surface resistivity and concrete 6 hours charge have good correlation relationship, which denote that the chloride diffusion coefficient and the surface resistivity of concrete are effective for evaluating the durability of concrete structures. The chloride diffusion coefficient of concrete is directly evaluated permeability of concrete box beam in service and may be used to predict the service life, which is fit to engineering applications and the concrete box beam is non-destructive. The concrete surface resistivity is easier available than the chloride diffusion coefficient, but it is directly not used to calculate the service life. Therefore the mathematical relation of the concrete surface resistivity and the concrete chloride diffusion coefficient need to be found, which the service life of reinforced concrete is obtained by the concrete surface resistivity.

반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구 (A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material)

  • 이창영;신두성;;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

인체전류를 기반으로 하는 감전의 위험성 평가방법 (A Method for Evaluating Electric Shock Hazards Based on Human Body Current)

  • 이복희;유양우;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Roles of Nickel Layer Deposition on Surface and Electric Properties of Carbon Fibers

  • Kim, Byung-Joo;Choi, Woong-Ki;Bae, Kyong-Min;Moon, Cheol-Whan;Song, Heung-Sub;Park, Jong-Kyoo;Lee, Jae-Yeol;Im, Seung-Soon;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1630-1634
    • /
    • 2011
  • Electroless plating of metallic nickel on carbon fiber surfaces was carried out to control specific electric resistivity of the fibers, and the effects of the nickel content and coating thickness on the electric properties were studied. The structural and surface properties of the carbon fibers were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). The specific resistivity of the fibers was measured using a four-point probe testing method. From the XPS results, the oxygen and Ni atomic ratio of the fibers was greatly enhanced as the plating time increased. Additionally, it was observed that the specific electric resistivity decreased considerably in the presence of metallic nickel particles and with the formation of nickel layers on carbon fibers.

전기비저항탐사에서 음의 겉보기 비저항 (Negative Apparent Resistivity in Resistivity Method)

  • 조인기;김정호;정승환;서정희
    • 지구물리와물리탐사
    • /
    • 제5권3호
    • /
    • pp.199-205
    • /
    • 2002
  • 전기비저항 탐사에서 측정되는 양은 두 전위전극 사이의 전위차이다. 이 전위차가 양일 경우에는 겉보기 비저항도 양의 값을 가지며, 음일 경우에는 겉보기 비저항도 음의 값을 나타낸다. 또한 측정되는 전위차의 부호는 전기장의 방향에 따라 좌우된다. 만약 측정방향과 전기장의 방향이 같다면, 전위차와 겉보기 비저항은 양의 값을 보이게 되며, 그 반대의 경우에는 음의 값을 나타낸다. 일반적으로 지표 전기비저항 탐사에는 측정방향과 1차 전기장의 방향이 같은 전극 배열을 사용하며, 이 방향의 1차 전기장은 2차 전기장에 비하여 항상 크다. 따라서 일반적인 전극배열을 사용하는 지표 전기비저항 탐사의 경우에는 지형이 평탄하고 잡음이 없다면 음의 겉보기 비저항은 나타나지 않는다. 그러나 시추공-시추공 전기비저항 탐사의 경우에는 1차 전기장의 방향과 측정방향이 일치하지 않으며, 경우에 따라서는 1차 전기장의 측정방향 성분이 2차 전기장의 측정방향 성분 보다 그 크기가 작을 수 있다. 이 경우 2차 전기장의 방향과 측정방향이 서로 반대일 경우에는 음의 겉보기 비저항이 나타날 수 있다. 따라서 음의 겉보기 비저항은 측정방향의 1차 전기장이 매우 작은 영역에서 발생할 가능성이 높다.

전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조 (Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju)

  • 손호응
    • 자원환경지질
    • /
    • 제32권2호
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

저항을 특성이 크게 상이한 다매질 유전체 내부의 전계 계산을 위한 표면 전하법 기법 (Electric Field Calculation of Composite Media Dielectric with Different Resistivity by Using Surface Charge Method)

  • 민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.391-393
    • /
    • 1997
  • Two kinds of the calculation technique are Investigated with 3D triangular SCM for the arrangement of the dielectric sphere with different resistivity under a uniform electric field. The calculation error of Method I is small outside the sphere, but considerably high Inside. On the other hand, the accuracy is much Improved even Inside the solid dielectric by Method II, which uses double layers of triangular charges on the dielectric boundary.

  • PDF