• Title/Summary/Keyword: surface comparison

Search Result 3,771, Processing Time 0.035 seconds

POM/MICOM Inter-Comparison in Modeling the East Sea Circulation

  • Kim, Kuk-Jin;Seung, Young-Ho;Suk, Moon-Sik
    • Ocean and Polar Research
    • /
    • v.23 no.2
    • /
    • pp.161-172
    • /
    • 2001
  • A model-to-model comparison is attempted between Princeton Ocean Model (POM) and Miami Isopycnic Coordinate Ocean Model (MICOM) as a first step to extend our knowledge of models' performances in studying the East Sea circulation. The two models have fundamentally different numerical schemes and boundary conditions imposed on these models are not exactly the same each other. This study indicates that MICOM has a critical weak point in that it does not reproduce the shallow surface currents properly while it handles the thermohaline processes and associated movements of intermediate and deep waters efficiently. It is suggested that the mixed layer scheme needs to be modified so that it can match with inflow boundary conditions in order to reproduce the surface currents properly in MICOM. POM reproduces the surface current pattern better than MICOM, although the surface currents in POM appear to undergo the unrealistic seasonal variation and have exaggeratedly large vertical scale. These defects seem to arise during the process of adapting POM to the East Sea, and removing these defects is left as a future task.

  • PDF

Analysis of surface form change after performing prophylaxis procedure on implant surface using various oral hygiene instruments (다양한 구강위생기구를 이용하여 임플란트 표면의 Prophylaxis 시행시 표면형태의 변화분석)

  • Lee, Sun-Goo;Lim, Sung-Bin;Chung, Chin-Hyung;Kwon, Sang-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.1-17
    • /
    • 2004
  • It is improtant that performing prophylaxis procedure on an infected implant surface in order to treat peri-implantitis should not change the surface roughness and composition, so that the surface can be recovered to almost same condition as initial implant surface. This thesis, therefore, studied an effect of various oral hygiene instrument on implant surface. A surface roughness measurement instrument and an infection electron microscope were used to observe a change on surface. The purpose of this study was to obtain a clinical guidelines during implant care and peri-implantitis treatment. The result were as follows 1. Ra values (surface roughness value) at experimental group 1, group 2, and group 5 were increased significantly as compared with comparison group(p<0.05). 2. When compared experimental group 1 with each experimental groups at which prohylaxis procedure was performed, mean values of Ra at experimental group 2, group 3, group 6, and group 7 were decreased significantly(p<0.05). 3. Mean value of Ra was lowest at experimental group 2, and highest at experimental group 2, and highest at experimental group 5. 4. Analysis of SEM showed that was significant surface change at experimental group 2, group 3, group 4, group 5, and group 6 as compared with comparison group(X1000). 5. Analysis fo EDX showed that a quantity of Ti on surface for experimental group 6 was very similar to that for comparison group. In conclusion, air-powder abrasive and citric acid, plastic instrument are safe methods to use for performing prophylaxis procedure on implant care or for cleaning and sterilization process on treatment of peri-implantitis, based on the result that those method did not affect implant surface roughness and Ti composition.

ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS (임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구)

  • Kim, Yong-Jae;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

The Effect of a Kettlebell Complex Program according to the Support Surface on Lower Extremity Muscle Activity and Balance in Baseball Players

  • Dae-Han Kang;Yong-Nam Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.312-316
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effect of a kettlebell complex program according to the support surface on the lower extremity muscle activity and balance of baseball players. Methods: The participants were divided into two groups; unstable support surface group 1 (11 people) performed the kettlebell complex program on an unstable support surface, and stable support surface group 2 (10 people) performed the kettlebell complex program on a stable support surface. Muscle activity was measured by surface electromyography. Dynamic balance was measured with a balance-measuring equipment. A paired t-test was used to compare groups before and after the experiment. An independent t-test was performed to determine the difference in the degree of change between the two groups before and after the experiment. Results: The intragroup comparison between stable support surface group 1 and 2 showed significant differences in muscle activity and sense of balance. In the comparison between the groups, the difference in muscle activity in unstable support surface group1 was significant in the biceps femoris and rectus femoris muscles, and significant differences were also found in the sense of balance. Conclusion: These results suggest that a kettlebell exercise on an unstable support surface is more effective in improving muscle activity and sense of balance than a kettlebell exercise on a stable support surface.

Comparison with decompression time and modes of air decompression tables in 5 countries (5개국 공기잠수감압표의 감압시간과 감압방법 비교)

  • Kang, Joonhyuk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.4
    • /
    • pp.445-453
    • /
    • 2016
  • Objectives: The objective of this study is to assess relative safety level of the decompression tables in Ministry of Employment and Labor Public Notice No. 2014-28 in comparison with overseas decompression tables. Methods: Decompression tables in the Public Notice No. 2014-28 were compared with examples from Japan, the USA, Canada, and France in terms of ascent rate, surface intervals after exceptional exposures, oxygen decompression and allowable partial pressure, depth limits in air diving, no-decompression limits, and decompression time and methods. Results: Public Notice No. 2014-28 does not include air diving depth limits, exceptional exposure limits, mandatory surface intervals after exceptional exposures, oxygen decompression, and surface decompression schedules. Its decompression time was found to be the shortest among the five decompression tables. Conclusions: Public Notice No. 2014-28 has the lowest safety level in comparison with overseas decompression tables. Deck decompression chambers are not applicable due to no regulations on surface interval and oxygen use in the chamber for decompression.

Comparison of Surface and Core Peptide Fraction from Apo B-100 of Human LDL (Low Density Lipoprotein)

  • Cho, Hyun-Mi;Shin, Seung-Uon;Kim, Tae-Woong
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.145-151
    • /
    • 1999
  • Apolipoprotein B-100 (apo B-100) is an important component in plasma low density lipoproteins (LDL). It function as the ligand for the LDL receptor in peripheral cells. The LDLs are removed from the circulation by both high-affinity receptor-mediated and receptor-independant pathways. LDLs are heterogeneous in their lipid content, size and density and certain LDL subspecies increase risk of atherosclerosis due to differences in the conformation of apo B in the particle. In the present study , surface and core peptide fraction of Apo B-100 have been characterized by comparing peptide-mapping and fluorescence spectroscopy. Surface fragments of apo B-100 were generated by digestion of LDL with either trypsin , pronase, or pancreatin elastase. Surface fractions were fractionated on a Sephadex G-50 column. The remaining core fragments were delipidated and redigested with the above enzymes, and the resulting core peptides were compared with surface peptides. Results from peptide-mapping by HPLC showed pronase-digestion was more extensive than trypsin -digestion to remove surface peptide fraction from LDL. Fluorescence spectra showed that core fractions contained higher amount of tryptophan than surface fractions, and it indicated that core fraction wa smore hydrophobic than surface fractions. A comparison of the behavior of the core and surface provided informations about the regions of apo B-100 involved in LDL metabolism and also about the structural features concerning the formation of atherosclerosis.

  • PDF

SWIR/VIS Reflectance Ratio Over Korea for Aerosol Retrieval

  • Lee, Kwon-Ho;Li, Zhangqing;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Relatively simplified method for determination of surface reflectance has been used by using the ratio between SWIR and VIS band reflectance over land surface. The surface reflectance ratios (SWIR/VIS) were estimated over land in Korea from Terra Moderate Resolution Imaging Spectre-radiometer (MODIS) L1 data. The ratios by using the minimum reflectance technique were lower than those by MODIS operational aerosol retrieval algorithm. Although the comparison between MODIS and sunphotometer Aerosol Optical Thickness (AOT) has a good correlation coefficient (R=0.84), slightly overestimated MODIS AOTs were shown with a slope of linear regression line of 0.89. The comparison between the ratio and AOT dearly exhibit that the error of MODIS AOT could be originated from the underestimated surface reflectances by MODIS operational algorithm.

Surface Temperature Retrieval from MASTER Mid-wave Infrared Single Channel Data Using Radiative Transfer Model

  • Kim, Yongseung;Malakar, Nabin;Hulley, Glynn;Hook, Simon
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.151-162
    • /
    • 2019
  • Surface temperature has been derived from the MODIS/ASTER airborne simulator (MASTER) mid-wave infrared single channel data using the MODerate resolution atmospheric TRANsmission (MODTRAN) radiative transfer model with input data including the University of Wisconsin (UW) emissivity, the National Centers for Environmental Prediction (NCEP) atmospheric profiles, and solar and line-of-sight geometry. We have selected the study area that covers some surface types such as water, sand, agricultural (vegetated) land, and clouds. Results of the current study show the reasonable geographical distribution of surface temperature over land and water similar to the pattern of the MASTER L2 surface temperature. The thorough quantitative validation of surface temperature retrieved from this study is somehow limited due to the lack of in-situ measurements. One point comparison at the Salton Sea buoy shows that the present estimate is 1.8 K higher than the field data. Further comparison with the MASTER L2 surface temperature over the study area reveals statistically good agreement with mean differences of 4.6 K between two estimates. We further analyze the surface temperature differences between two estimates and find primary factors to be emissivity and atmospheric correction.

Comparison of Topex/poseidon Sea Surface Heights with Tide Gauge Sea Levels in the South Indian Ocean (남인도양에서의 Topex/Poseidon sea surface heights와 tide gauge sea levels간의 비교)

  • YOON Hong-Joo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.3
    • /
    • pp.368-373
    • /
    • 1999
  • Topex/Poseidon sea surface heights are compared to tide gauge sea levels in the South Indian Ocean in the period of January 1993 to December 1995. A user's handbook (AVISO) for processing sea surface height data was used in this study. Topex/Poseidon sea surface heights were obtained from satellite data at the proximity of tide gauge stations. These data were reproduced by a linear interpolation with the interval of 10 days and were processed by the Gaussian filter with a 60-day window. The tide gauge sea levels were obtained in the same manner as the satellite data. The main results on RMS (Root-Mean-Square) and CORR (CORRelation coefficient) in our study were shown as follows: 1) on the characteristics between two data (in-situ and model data), the results (RMS=2.96 cm & CORR=$92\%$ in the Amsterdam plateau, and RMS=3.45 cm & CORR=$59\%$ in the Crozet plateau) of the comparison of Topex/Poseidon sea surface heights with tide gauge sea levels, which was calculated by in-situ data of obsewed station showed generally low values in RMS and high values in CORR against to the results (RMS=4.69 cm & CORR=$79\%$ in the Amsterdam plateau, and RMS= 6.29 cm & CORR= $49\%$ in the Crozet plateau) of the comparison of Topex/Poseidon sea surface heights with tide gauge sea levels, which was calculated by model data of ECMWF (European Center for Medium-range Weather Forecasting), and 2) on the characteristics between two areas (Kerguelen plateau and island), the results (RMS=3.28 cm & CORR= $54\%$ in the Kerguelen plateau) of open sea area showed low values in RMS and high values in CORR against to the results (RMS= 5.71 cm & CORR=$38\%$ in the Kerguelen island) of coast area, respectively.

  • PDF

The Surface Properties using various separating materials of dental gypsum products (다양한 석고 분리제를 이용한 치과용 석고의 표면 특성에 관한 연구)

  • Sung, Hwan-Kyung;Lee, Gyu-Sun;Hwang, Jae-Sun
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Gypsum products are used for the preparation of stone casts of oral and maxillofacial structures and as important adjuncts to dental laboratory operations involved in the production of dental prosthesis. Accuracy and dimensional stability over time are properties of concern in fixed prothodontics. Gypsum products used in denstry are a form calcium sulfate hemihydrate and are classified as 1 of 5 types according to International Standard Organization(ISO) 6873. All die materials exhibit some dimensional change during setting, but expansion and contraction during setting and dimensional changes in response to varations in temperature and the water-powder ratio must be minimal. Although numerous investigators have studied the properties of die materials, several products have been introduced recently with manufacturer claims of superior dimensional stalility. The aim of this study was to determine the surface properties using various separating materials of dental gypsum products The results were as follows 1. In the comparison of first and second plaster distances before separation in different separating agent, there was no significant difference except using Trio separating agent. The interface using Trio separating agent forms like to pores. 2. In the comparison of first and second plaster distances after separation in different separating agent, there was significant difference. The interface of plasters using WD-40, Trio and Vaseline was showed some gaps. Each they were measured at average 7.97 $\pm$ 2.07 ${\mu}m$, 63.09 $\pm$ 23.25 ${\mu}m$, 27.59 $\pm$ 4.19 ${\mu}m$. 3. In the comparison of the surface, the surface of control sample(using none seperating agent) showed irregular properties and the surface using Trio and Vaseline become wrinkled. Specially the surface using Vaseline was showed shiny properties. But the surface using MAGIC SEP, Plaster seperating agent, WD-40 showed regular properties.

  • PDF