• 제목/요약/키워드: surface balance

Search Result 862, Processing Time 0.024 seconds

Water Balance Evaluation of Final Closure Cover for Near- surface Radioactive Wastes Disposal Facility

  • Keunmoo Chang;Park, Joo-Wan;Yoon, Jeong-Hyoun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.274-282
    • /
    • 2000
  • The simulation of water balance was conducted for suggested four alternative multi-layer cover design of near-surface radioactive waste disposal facility under domestic climate condition. The analysis was also conducted for the most favorable one out of four alternative cover design under conservative scenarios. Until 100 years after closure of disposal vault, the infiltration flux for the most favorable cover design was negligible even under doubling of the ambient precipitation condition. When the degradation of asphalt and geomembrane after 100 years of closure was considered, the infiltration flux significantly increased almost to the design criteria of cover system in I' Aube disposal facility. And it was found that the hydraulic conductivity of bentonite/sand as a bottom barrier should be no greater than 1$\times$10$^{-7}$ cm/sec recommended by U.S. EPA.

  • PDF

Effect of Active Vibro-Swing Exercise of Upper Limb on Physical Capacity and Vasomotor for Middle Aged Women (상지 능동 진동운동이 중년여성의 신체능력 및 혈관운동성에 미치는 영향)

  • Lee, Hyun Ju;Yim, Hyun Seung;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.264-271
    • /
    • 2020
  • The purpose of this study was to investigate the effects of active vibration exercise of upper limb on physical capacity index (endurance, grip strength, balance, and flexibility) and vasomotor index (capillary length and body surface temperature) in middle aged women. 20 participants randomly divided into two groups: vibro-swing exercise (VSE) and non vibro-swing exercise (NVSE). Subjects in each group measured the 30 second arm curl test, hand dynamometer, one leg standing test, back scratch test, nail fold capillary microscope (NFM), and digital infrared thermal imaging (DITI) before and after exercise. The results showed that active vibration exercise of upper limb with vibro-swing equipment increased the endurance, balance ability, and the capillary length. In addition, changes in body temperature immediately after exercise were predicted to affect vasomotor. Active vibration exercise of upper limb has the advantage of being able to exercise anywhere regardless of the location by inducing different frequency changes in movement of various ranges and velocity. For this reason, the combination of vibration and active movement can be expected the physiological effects when producing exercise programs for middle aged women.

Decomposable polynomial response surface method and its adaptive order revision around most probable point

  • Zhang, Wentong;Xiao, Yiqing
    • Structural Engineering and Mechanics
    • /
    • v.76 no.6
    • /
    • pp.675-685
    • /
    • 2020
  • As the classical response surface method (RSM), the polynomial RSM is so easy-to-apply that it is widely used in reliability analysis. However, the trade-off of accuracy and efficiency is still a challenge and the "curse of dimension" usually confines RSM to low dimension systems. In this paper, based on the univariate decomposition, the polynomial RSM is executed in a new mode, called as DPRSM. The general form of DPRSM is given and its implementation is designed referring to the classical RSM firstly. Then, in order to balance the accuracy and efficiency of DPRSM, its adaptive order revision around the most probable point (MPP) is proposed by introducing the univariate polynomial order analysis, noted as RDPRSM, which can analyze the exact nonlinearity of the limit state surface in the region around MPP. For testing the proposed techniques, several numerical examples are studied in detail, and the results indicate that DPRSM with low order can obtain similar results to the classical RSM, DPRSM with high order can obtain more precision with a large efficiency loss; RDPRSM can perform a good balance between accuracy and efficiency and preserve the good robustness property meanwhile, especially for those problems with high nonlinearity and complex problems; the proposed methods can also give a good performance in the high-dimensional cases.

Design of Ball and Plate Robot controller using Single Camera (단일 Camera를 이용한 Ball and Plate 로봇 제어장치 설계)

  • Park, Yi-Keun;Park, Ju-Youn;Park, Seong-Mo
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.213-225
    • /
    • 2013
  • This paper proposes a design method of ball-plate robot controller using single camera and two motors to balance the ball on plate and reduce steady state control error. To design the ball-plate system, it is necessary to observe state of the ball and maintain balance of the plate. The state of the ball is tracked by using the CAMShift algorithm and position error of the ball is compensated by the Kalman filter. Balance of the plate is controlled by driving two motors and we used DC motors which has smaller measurement error. Due to surface condition of the plate or tracking error of ball's position, there are small errors remained. These errors are accumulated and disturb maintaining balance of the ball. To handle the problem, we propose a controller supplemented with an integrator.

Inspection of combination quality for automobile steel balance weight using laser line projector and USB camera (레이저 선 프로젝터와 USB 카메라를 이용한 자동차용 철 밸런스 웨이트의 결합상태 검사)

  • Choi, Kyung Jin;Park, Se Je;Lim, Ho;Park, Chong Kug
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, sensor system and inspection algorithm in order to inspect steel balance weight for automobile is described. Steel balance weight is composed of clip and weight, which is joined by press process. The defective one has a gap between clip and weight. To detect whether there is a gap, sensor system is simply configured with laser line projector and USB camera, which make it possible to measure the height difference of clip and weight area. Laser line pattern which is made on the surface of a balance weight is captured by USB camera. In case that USB camera is used in machine vision, barrel distortion caused by wide angle lens makes the captured image distorted. Image warping function is applied to correct the distortion. Simple image processing algorithm is applied to extract the laser line information and whether it is good or not is judged through the extracted information.

Effect of tDCS and Lumbar Motor Control Exercise on Static Balance and Disability in Chronic Low Back Pain (tDCS와 요추 움직임 조절 운동이 만성요통환자의 정적균형과 요통장애지수에 미치는 영향)

  • Jeong, Yong-sik;Shin, Eui-ju
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Background: The purpose of this study was to investigate the effects on static balance and disability in chronic low back pain with lumbar rotation extension subgroup of trascranial direct current stimulation (tDCS) and lumbar motor control exercise (MCE). Methods: In 40 male low back pain with lumbar rotation extension subgroup subjects were recruited for the study. Subjects were randomly allocated into two groups. Experimental groups received tDCS and MCE, Control groups received sham-tDCS and MEC. Before and after intervention, measured in surface area, whole path length and Roland-Morris low back pain questionnaire (RMQ). Results: Showed a significant static balance and disability from the experimental groups compared to the control group. Showed a no significant RMQ score from experimental groups compared to the control group. Conclusions: tDCS and lumbar MCE showed the increased static balance in chronic low back pain with lumbar rotation extension subgroup.

  • PDF

The Influence of Foot Angle on Standing Balance Upon the Unstable Platform (불안정한 바닥위에서 발목각도가 기립균형에 미치는 영향)

  • Lee, Han-Suk;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.34-44
    • /
    • 1997
  • The purpose of this study was to compare the balance ability at different foot angle with KAT 2000 (Breg, Inc., Vista, CA. 1994). Forty-nine (male 24, female 25) normal subjects participated in this study. All subjects were assessed under two conditions. One was eye-opened condition and the other one was eye-closed one in 3 psi surface condition. All subjects were tested at different foot angle that were toe-in $25^{\circ}$, $45^{\circ}$, toe-out $25^{\circ}$ and $45^{\circ}$. The subject attempted to keep the platform as stable as possible with eyes closed and with eyes opened for every 20 seconds. The starting position was that subject crossed their arms across chest and flexed knees slightly. The results of each test were showed by a score on screen, which meant balance index. The se collected data were analyzed by using oneway ANOVA, Scheffe test, and t-test. The results of this study were as follows: 1. When the foot angle were changed, balance index was the lowest in toes-out $25^{\circ}$ condition and greatest with toes-in $45^{\circ}$ with eyes opened and with eyes closed. There were statistically significant difference with eyes opened and with eyes closed (p<0.05). 2. There was statistically significant difference in balance index according to visual condition and the balance index tested with eyes closed was higher than with eyes closed(p<0.05). 3. There was statistically significant difference in balance index by gender(p<0.05).

  • PDF

A Study on the Color Reproduction of Halftone Image by used Factor N and Process Ink Characteristics (Factor N와 잉크특성을 고려한 망점화상의 색재현예측에 관한 연구)

  • 김성근
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.13-27
    • /
    • 1994
  • Litho printing ink vehicles based on rosin modified phenolic are faster drying, have better durability, are harder and glosser and have greater resistance to water than ones based on ester gums. Ink-Water balance and rheological properties are important in litho printing process. These physical properties is concerned with molecular weight of Resin to use vehicle. So this paper was studied about the effects of changing molecular weight of Rosin modified phenolic on surface tension, viscosity, pseudoplasticity and printablility of Litho Inks. The results were as follows. 1) The surface tension of model inks depended on the molecular weight of the resin : Dispersion componnent of ink increase but non dispersion component decrease as molecular weight of Resin increase. 2) Water pick-up of litho ink is more fast balance, using low molecular weight of Resin. 3) Viscosity, Yield value and Newtonian value of model inks increase as molecular weight of Resin increase. 4) The litho ink prepared with the modified phenolic of which molecular weight is about 20000 showed the highest printing density and gloss.

  • PDF

The Effect of Changing Molecular Weight of Rosin Modified Phenol Resin on Physical Properties of Litho Printing Inks (Rosin변성 phenol수지의 분자량 변화에 따른 평판인쇄 잉크의 물성변화에 관한 연구)

  • SungBinKim
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.145-157
    • /
    • 1994
  • Litho printing ink vehicles based on rosin modified phenolic are faster drying, have better durability, are harder and glosser and have greater resistance to water than ones based on ester gums. Ink-Water balance and rheological properties are important in litho printing process. These physical properties is concerned with molecular weight of Resin to use vehicle. So this paper was studied about the effects of changing molecular weight of Rosin modified phenolic on surface tension, viscosity, pseudoplasticity and printability of Litho Inks. The results were as follows. 1) The surface tension of model inks depended on the molecular \veight of the resin : Dispersion componnent of ink increase but non dispersion component decrease as molecular weight of Resin increase. 2) Water pick-up of litho ink is more fast balance, using low molecular weight of Resin. 3) Viscosity, Yield value and Newtonian value of model inks increase as molecular weight of Resin increase. 4) The litho ink prepared with the modified phenolic of which molecular weight is about 20000 showed the highest printing density and gloss.

  • PDF

Developing a Model to Predict Road Surface Temperature using a Heat-Balance Method, Taking into Traffic Volume (교통량을 고려한 열수지법에 의한 노면온도 예측모형의 구축)

  • Son, Young-Tae;Jeon, Jin-Suk;Whang, Jun-Mun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.2
    • /
    • pp.30-38
    • /
    • 2015
  • In this study, to improve effectiveness of road management services and the safety of the road in winter, road surface temperature prediction model was developed. We have utilized the existing input data of meteorological data and additional traffic data. This Road surface temperature prediction model was utilizing a Heat-Balance Method additionally considering amount of traffic that produce heat radiation by vehicle-tire friction. This improved model was compared to the based model to check into influence of traffic affecting the road surface temperature. There were verified by comparing the real observed road surface temperature of the third Gyeong-In highway and road surface temperature from the two models. As a result, the error of real observed and the predicted value (RMSE) was found to average $1.97^{\circ}C$. Observed road surface temperature was dramatically affected by the sunlight from 6 a.m. to 2 p.m. and degree of influence decreases after that. The predictive value of the model is lower than the observed value in the afternoon, and higher at night. These results appear due to the shielding of solar radiation caused by the vehicle in the afternoon and at night, the vehicle appeared to cause thermal heat supply.