• Title/Summary/Keyword: surface adsorption

검색결과 2,338건 처리시간 0.026초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

인천국제공항 식재기반 구조 및 토양특성 연구 (A Study on the Structure Characteristics of Planting Ground in Incheon International Airport, Korea)

  • 이승원;한봉호;이경재;곽정인;염정헌
    • 한국조경학회지
    • /
    • 제43권3호
    • /
    • pp.77-91
    • /
    • 2015
  • 본 연구는 대규모 매립지에 조성된 인천국제공항을 대상으로 수목 식재기반에 대한 구조적, 이화학적 특성을 파악함으로써 합리적인 토양관리 방향을 제시하고자 하였다. 세부 연구 대상지는 국제업무단지, 여객터미널, 공항지원단지, 자유무역지역, 진입도로 등 5개소이었다. 인천국제공항 수목생육 기반에 대한 토양 구조분석결과 표토로부터 80cm 이내에 경반층 또는 이질층의 토양층위가 존재하는 조사구는 총 27개소 중 9개소이었으며, 성토재료로 자갈 매립(4개소), 준설토와 혼합된 재료 매립(2개소), 점토가 다량 포함되어 투수가 불량한 성토 재료 사용(3개소), 폐골재를 매립한 경우(1개소) 등이었다. 토양의 물리적 특성으로 토양경도는 성토층 평균 $11.5kg/cm^2$이었고, 토성은 모래함량이 많은 사토, 사양토, 양질사토 등이었다. 화학적 특성으로서 토양산도는 성토층 평균 pH 6.7이었으며, 유기물함량은 0.7%, 전기전도도(EC)는 0.0dS/m, 교환성양이온함량은 $Ca^{2+}$ 3.4cmol/kg, $Mg^{2+}$ 1.5coml/kg, $K^+$ 0.3cmol/kg, $Na^+$ 1.0cmol/kg, 교환성양이온치환용량(CEC)은 11.0cmol/kg이었다. 성토층의 절대적 평균치는 대부분 조경설계기준을 만족하였으나 매립지토양특성상 층위별 조사구별 편차를 반영할 수 없는 한계가 있어 성토층위별로 분석한 교환성양이온별 염기포화도(BSP)는 소성토지역 $Ca^{2+}$ 29.9%, $Mg^{2+}$ 13.3%, $K^+$ 3.7%, 중성토지역 $Ca^{2+}$ 33.3%, $Mg^{2+}$ 17.0%, $K^+$ 2.7%, 대성토지역 $Ca^{2+}$ 32.6%, $Mg^{2+}$ 12.2%, $K^+$ 1.9%이었다. 교환성나트륨백분율(ESP)은 소성토지역 16.4%, 중성토지역 7.5%, 대성토지역 4.7%이었고, 나트륨흡착비(SAR)는 소성토지역 0.8, 중성토지역 0.3, 대성토지역 0.2이었다. 성토재료의 불균질과 불량, 준설토의 교란, 답압에 의한 높은 토양경도와 지중의 경반층형성, 낮은 유효토심 등의 물리적 요인과 높은 pH, 염기밸런스 불균형, 낮은 유기물, 유효인산 등은 식물생육에 영향을 주는 것으로 분석되었다.

메탄의 부분산화반응으로부터 수소제조를 위한 촉매담체(SPK, SPM) 제조 및 Ru 담지 촉매의 활성도 조사 (Catalyst Carriers Preparation and Investigation of Catalytic Activities for Partial Oxidation of Methane to Hydrogen over Ru Impregnated on SPK and SPM Catalysts)

  • 서호준;번세검;김용성;정도성;강웅일;조영복;김상채;권오윤;선우창신;유의연
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.581-584
    • /
    • 2008
  • 중기공성 층상화합물의 촉매 담체를 제조하고, 메탄으로부터 수소를 제조하기 위한 활성도를 평가하기 위해서 고정층 상압 유통식 반응기를 사용하여 Ru(3)/SPK와 Ru(3)/SPM 촉매상에서 메탄의 부분산화반응를 수행하였다. 또한, BET, TEM, TPR를 사용하여 촉매 및 담체의 특성을 분석하였다. 촉매 담체인 실리카 지주 $H^+-kenyaite$(SPK) 와 $H^+-magadite$(SPM)의 BET 비 표면적은 각각 $760m^2/g$$810m^2/g$ 이었고, 평균기공크기는 각각 3.0 nm와 2.6 nm 이었다. $N_2$-흡착등온선은 히스테리시스가 잘 발달된 IV형이었으며, TEM으로 중기공성 층상화합물이 잘 만들어졌음을 확인할 수 있었다. Ru(3)/SPK와 Ru(3)/SPM 촉매는 973 K, $CH_4/O_2=2$, $1.25{\times}10^{-5}g-Cat.hr/ml$의 반응조건에서 각각 90%, 87%의 수소의 수율를 얻을 수 있었으며, 약 60시간 까지도 높은 수소 수율을 유지하였다. Ru(3)/SPK와 Ru(3)/SPM 촉매의 TPR 피크는 각각 453K와 413K의 근방에서 비슷한 환원도를 보여주었다. 이러한 분석자료로부터 SPK와 SPM은 산화반응의 촉매 담체로서 구비조건(비 표면적, 열안정성, 평균기공크기 등)를 갖추고 있음을 알 수 있었다.

황토와 광물성 한약재의 적조구제 특성에 관한 연구 (A Study of Removal Property of Harmful Algal Blooms by Hwangto and Oriental Mineral Medicines)

  • 김필근;성규열;장영남;박맹언
    • 한국광물학회지
    • /
    • 제19권4호
    • /
    • pp.277-289
    • /
    • 2006
  • 황토와 황토 구성 물질 중 철과 알루미늄 함량을 지배하는 점토광물과 철산화광물을 주성분으로 하는 광물약에 대한 적조제거 효율을 조사하여 유효성분을 탐색하였다. 적조생물의 구제효과실험은 $F_2$배지 내에서 배양한 C. polykrikoides에 황토와 광물약을 10 g/L 기준으로 살포하고, 0, 10, 30 및 60분의 시간별로 살아있는 개체수를 광학현미경을 이용하여 3회 이상($3{\sim}5회$) 계수하였으며, 동일한 실험을 3번 반복하여 그 값의 평균 백분율(%)로 표시하였다. 황토의 적조구제효과 실험결과, 5종의 황토 중 철과 알루미늄 함량이 가장 높은 A 황토의 적조구제효율이 99%(60분 경과)로 가장 높게 나타났다. 점토 함유 광물약 중 적석지가 60분경과 시 92%의 제거효율로 가장 높은 구제효율을 보였으며, 감토(91%)>백석지(89%)>수운모(81%) 순의 제거효율을 보인다. 철함유광물약 중 미립의 토상 대자석이 30분 경과 시 100%, 우여량은 60분경과 시 95%의 높은 제거효율을 보인다. 특히 미립의 토상 대자석은 황토의 10%인 1 g/L 투여 시에도 60분 경과 시에 100%의 높은 제거효율을 나타내었다. 또한, 적조 구제기작은 흡착-팽창-연쇄군체 분리-살조로 구분될 수 있다.

AsO4로 치환된 슈베르트마나이트의 중금속 흡착 특성 (Heavy Metal Adsorpton on AsO4-Substituted Schwertmannite)

  • 김병기;김영규
    • 한국광물학회지
    • /
    • 제25권2호
    • /
    • pp.85-94
    • /
    • 2012
  • 산성광산배수에 존재하는 $AsO_4$는 슈베르트마나이트의 $SO_4$를 치환하여 강하게 흡착되고 이로 인하여 슈베르트마나이트가 쉽게 침철석으로 전이되지 않게 해준다. 이러한 슈베르트마나이트에 대하여 주요 중금속 흡착에 대한 연구는 일부 이루어져 있으나 실제 $AsO_4$로 치환된 슈베르트마나이트에 대한 흡착 특성에 대해서는 기존에 연구된 바가 없다. 본 연구에서는 $AsO_4$로 치환된 슈베르트마나이트에 대하여 Cu, Pb, Zn 등의 대표적인 중금속 세 종류에 대하여 각 중금속의 농도가 3, 10, 30, 100 mg/L에 대하여 pH 4와 6의 두 범위에서 시간에 따른 흡착 실험을 실시하였다. 흡착 실험 결과 모든 중금속에 대하여 pH 6인 경우 pH 4에 비하여 흡착량이 큰 범위로 증가하였다. 전체적인 흡착량에 있어서 두 pH 범위에서 모두 Pb가 가장 큰 흡착량은 보였으며 Cu와 Zn의 흡착량은 비슷하였다. 시간에 따른 흡착속도는 전체적으로 모든 농도에 대하여 시간이 증가하면서 흡착량은 증가하였으나 Zn의 경우 대부분의 흡착이 초기에 일어나 시간이 지나면서 뚜렷한 흡착의 증가는 일어나지 않았다. 이러한 흡착량 증가는 특히 고농도의 용액인 100 mg/L에서 그 증가하는 양상이 뚜렷하였다. 다양한 흡착속도 모델을 적용한 결과 $AsO_4$로 치환된 슈베르트마나이트에서 일어나는 중금속의 흡착속도는 아마도 확산에 의하여 주로 좌우되는 것으로 나타났다. 기존의 연구에서 순수한 슈베르트마나이트가 pH 6에서 세 중금속에 대하여 거의 비슷한 흡착량을 보이고 pH 4에서는 Cu와 Pb가 비슷하게 Zn보다 높은 흡착량을 보이는 것을 고려하면 본 연구 결과 $AsO_4$ 슈베르트마나이트는 확연하게 다른 흡착 경향을 보이고 이는 $AsO_4$가 슈베르트마나이트의 $SO_4$를 치환됨으로 인하여 슈베르트마나이트의 표면 및 흡착특성이 달라짐을 지시한다. 이는 산성광산배수에서 $AsO_4$의 흡착이 슈베르트마나이트의 안정성뿐만 아니라 각 중금속의 거동에도 큰 영향을 줄 수 있음을 보여준다.

조수에 의한 콘크리트 침식방지법에 관한 연구(ll) (Studies on Preventive Methods Against Concrete Corrosion by Sea Water (ll))

  • 고재군
    • 한국농공학회지
    • /
    • 제15권2호
    • /
    • pp.3018-3030
    • /
    • 1973
  • 이 연구는 해수작용에 대한 콘크리트의 내구성시험의 일환으로 각종 배합설계의 콘크리트에 대하여 1년간 실내에서 해수에 침지하여 압축강도와 부식율을 규명하고저 시도하였다. 각종 콘크리트의 배합설계에 있어서 보통시멘트만을 사용한 것, 혼화제로서 후라이애쉬, 포조리스, 빈솔레진 등을 각각 보통시멘트에 사용한 것, 그리고 포조란 시멘트만을 사용한 것 등으로 구분하고 각 콘크리트 공시체는 K.S 규정에 준하여 만들어 재령 7일 및 28일 양생하였다. 그리고 압축강도시험은 수중과 해수에 각각 1년간 침지한 것에 대하여 강도를 측정하고 부식율시험은 해수중에 1년간 침지한 것에 대하여 부식율을 측정하였다. 이와같은 콘크리트의 압축강도시험과 부식율 시험에 대한 결과를 요약하면 다음과 같다. (1) 압축강도에 있어서 보통콘크리트는 수중이나 해수중에 다 같이 다른 콘크리트의 강도보다 낮으므로 포조란시멘트나 혼화제인 후라이애쉬, 포조리스. 빈솔레진은 각각 그 효과가 인정되었다. (2) 포조란시멘트는 수중에서 강도가 다른 콘크리트보다 가장 높았으나 해수중에서는 후라이애쉬보다 낮은 강도를 나타내었다. 따라서 포조란시멘트는 해수중에서 보다 수중에서 강도상 효과가 있다는 것을 알 수 있다. (3) 후라이애쉬는 수중에서와 해수중에서 다 같이 장기강도에 있어서 높은 강도를 갖인 특성이 있다는 것을 나타내었고, 수중에서는 포조란시멘트에 비하여 강도가 낮었으나 해수중에서는 오히려 포조란 시멘트의 강도를 능가하고 있어 해수중에서는 포조란 시멘트보다 강도상 더욱 그 효과가 크다는 것을 알 수 있다. (4) 포조리스는 후라이애쉬와 포조란시멘트에 비해서 그 효과가 떨어지나 빈솔레진에 비해서는 강도상에 있어서 항상 그 효과가 인정되공 있다. (5) 빈솔레진은 포조란시멘트나 혼화제중에서 강도상 가장 그 효과가 낮으나 보통콘크리트에 비하면 그 효과는 수중이나 해수중에서 다 같이 인정되고 있다. (6) 콘크리트의 압축강와 흡수율과의 관계는 후라이애쉬를 제외하면 다른 재령에서와 같이 흡수율이 적을수록 압축강도는 증가되며 회기직선관계가 성립되었다. 그러나 후라이애쉬는 장기강도에서 그 특징이 현저히 나타나고 있어 다른 콘크리트의 흡수율에 비하여 현저히 높은 강도를 나타내고 있다. (7) 부식율에 있어서는 1년간 해수작용을 받었을 때 각 콘크리트의 유의적인 부식율이 인정될 수 없으며 외관상에서도 부식현상을 식별할 수 없었다.

  • PDF

청정수소 생산을 위한 암모니아 분해 반응에서 Ni/Zeolite 촉매의 반응활성에 관한 연구 (Ammonia Decomposition over Ni Catalysts Supported on Zeolites for Clean Hydrogen Production )

  • 김지유;김경덕;정운호;박용하;이기봉;구기영
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.19-26
    • /
    • 2023
  • 수소는 화석연료를 대체할 수 있는 COx-free 에너지원으로 사용량은 지속적으로 증가할 것이다. 수소는 단위 질량당 에너지 함량이 높으나, 낮은 저장 밀도와 장기 저장의 어려움으로 저장 및 운송에 한계가 존재한다. 반면, 암모니아는 단위 부피당 저장용량이 크고, 비교적 액화가 용이하여 대용량 수소를 저장 및 운송할 수 있는 수소 운반체로 주목받고 있다. 암모니아 분해를 통한 수소 생산 반응은 흡열반응으로 공정의 효율성 및 경제성을 위해 저온 활성이 우수한 촉매 개발이 요구된다. 본 연구에서는 활성금속 Ni의 고분산 담지를 위해 넓은 비표면적의 제올라이트를 지지체로 사용하였으며, 제올라이트 종류(5A, NaY, ZSM5)에 따른 특성(기공구조, 양이온, Si/Al-비)이 촉매 활성 및 반응 특성에 미치는 영향을 확인하였다. 5A 제올라이트는 표면, 기공, 구조체 내에 Ni 을 고분산 담지를 가능하게 하였으며, 낮은 Si/Al-비로 인한 풍부한 산점은 암모니아 흡착을 증가시켰다. 또한, 지지체에 포함된 Na과 Ca 양이온으로 인한 중간-염기점은 질소 탈착속도를 향상시켰다. 따라서, 15wt%Ni/5A 촉매는 강한 금속-지지체 상호작용과 중간-염기점을 통한 질소 탈착 속도 향상으로 가장 우수한 암모니아 전환율과 높은 수소 생성율 23.5 mmol/gcat·min (30,000 mL/gcat·h, 600 ℃)을 보였다.

패각의 종류 및 소성 여부에 따른 호분안료의 특성 평가 (Characteristics Evaluation of Hobun Pigments according to Shell Types and Calcination)

  • 박주현;이선명;김명남;홍진영
    • 자원환경지질
    • /
    • 제56권6호
    • /
    • pp.899-909
    • /
    • 2023
  • 본 연구는 전통적으로 채색문화유산의 백색 무기안료로 사용된 호분안료를 대상으로 패각의 종류 및 소성 여부에 따른 재료과학적 특성을 분석하고, 보존환경 안정성을 평가하였다. 이를 위해 벚굴, 대합 패각 2종으로 제조된 호분과 이를 1,150 ℃에서 소성한 호분 2종을 수집하였다. 성분분석 결과, 소성 전의 호분안료는 calcite, aragonite 등의 탄산칼슘이고, 소성 후에는 portlandite가 주구성 물질로 calcite가 혼재되어 있었다. FE-SEM분석 결과, 소성 전에는 패각 종류에 따라 고유의 입형 조직을 보이지만 소성 후에는 다공성 입자의 조직 형태로 변하였다. 이에 따라 안료의 흡유량이 상당히 커지는 것을 볼 수 있다. 또한 소성 전보다 소성 후 백색도가 향상되는데, 대합 호분 안료(CS)의 색도 개선율이 더 높았다. 촉진내후성 시험 결과, 호분안료 채색시편은 시험 후 색차값이 2미만으로 육안으로 인지하기 어려운 정도였다. 특히 소성 전에 비해 소성 후 호분안료의 색차값이 작은 것으로 색 안정성이 높아진 것을 알 수 있다. 반면 소성 전보다 소성 후 시편에서 채색층 도막의 안정성이 떨어지는 것을 확인하였다. 항진균 효과는 공시균으로 Aspergillus niger, Tyromyces palustris, Trametes versicolor를 사용하였고, 호분안료가 곰팡이균에 대한 예방 보호적 효과가 있는 것으로 드러났다. 특히 소성과정을 거친 안료의 항진균 효과가 우수했는데, 이는 안료의 재료적 특성상 염기성이 강해진 것에 기인된 결과로 판단된다.