• Title/Summary/Keyword: surface

Search Result 79,828, Processing Time 0.101 seconds

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.

A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR (침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구)

  • Choi, Yong-Bum;Lee, Hae-Seung;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7227-7236
    • /
    • 2015
  • The survey revealed that, due to the discharge characteristics of seafood wastewater, irregular inflow loads were caused, making it difficult to treat the wastewater safely. It is crucial for the operation of pressure and floating tanks for the treatment of high-concentration organic wastewater such as seafood wastewater. The survey of operation factors for the pressure and floating tanks revealed this: A/S ratio 0.05 (design criteria 0.01), the pressurized air pressure 8bar(design criteria 6bar), the pressure tank pressure 6bar (design criteria 4.5bar), and HRT 60sec(design criteria: 10sec). Also, the recirculation rate was changed to over 40%(design criteria: 30%), and the surface load rate was changed to under $13.7m^3/m^2{\cdot}hr$(design criteria: under $17.7m^3/m^2{\cdot}hr$); thus, compared to the initial design criteria, the operation factors were changed according to inflow characteristics, thus enhancing the pressure and floating tank performance. The survey of inflow load revealed BOD 140.7%, $COD_{Mn}$ 120.32%, and SS 106.3%, compared to the inflow design criteria, as well as T-N 135.5% and T-P173.3%, higher than the design criteria. The survey of the treatment facility annual operation cost revealed high portions in sludge treatment cost(27.7%) and chemicals costs(26.0%), and the sludge treatment cost will likely further increase due to the ban on ocean dumping. The unit cost for the treatment of seafood wastewater was found to be KRW 3,858 per ton, more than 27 times higher than the sewage treatment cost(KRW 142.6/ton), presumably because the seafood wastewater contains high-concentration organic substances and nutritive salts.

Influence of additional etching on shear bond strength of self-etching adhesive system to enamel (부가적인 산부식이 자가산부식 접착제의 법랑질에 대한 전단결합강도에 미치는 영향)

  • Yoo Sun-Jin;Kim Young-Kyung;Park Jeong-Won;Jin Myoung-Uk;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.263-268
    • /
    • 2006
  • Recently, self-etching adhesive system has been introduced to simplify the clinical bonding proce- dures. It is less acidic compared to the phosphoric acid, thus there is doubt whether this system has enough bond strength to enamel. The purpose of this study was to investigate the influence of additional etching on the adhesion of resin composite to enamel. Ninety extracted bovine permanent anterior teeth were used. The labial surfaces of the crown were ground with 600-grit abrasive paper under wet condition. The teeth were randomly divided into six groups of 15 teeth each. Clearfil SE $Bond^{\circledR},\;Adper^{TM}$ Prompt L-Pop and Tyrian $SPE^{TM}$ were used as self-etching primers. Each self-etching primers were applied in both enamel specimens with and without additional etching. For additional etching groups, enamel surface was pretreated with 32% phosphoric acid (UNI-ETCH, Bisco, Inc., Schaumburg, IL. USA). Hybrid resin composite Clearfil AP-X, (Kuraray Co., Ltd., Osaka, Japan) was packed into the mold and light-cured for 40 seconds. Twenty-four hours after storage, the specimens were tested in shear bond strength. The data for each group were subjected to independent t - test at p < 0.01 to make comparisons among the groups. In Clearfil SE $Bond^{\circledR}$, shear bond strength of additional etching group was higher than no additional etching group (p < 0.01). In $Adper^{TM}$ Prompt L-Pop and Tyrian SPE, there were no significant difference between additional etching and non-etching groups (p > 0.01). In conclusion, self-etching adhesive system with weak acid seems to have higher bond strength to enamel with additional etching, while self-etching adhesive system with strong acid seems not.

PROPERTIES OF CALCIUM HYDROXIDE-EUGENOL COMPOUND (수산화칼슘-유지놀 화합물의 물성)

  • Park, Joon-Chol;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.408-415
    • /
    • 1999
  • When a zinc-oxide eugenol type sealer was placed in root canals treated previously with calcium hydroxide, acceleration of its setting and the yellowish discoloration were observed clinically. The purpose of this study was to evaluate the properties of calcium hydroxide-eugenol compound. Some physical properties of calcium hydroxide-eugenol compound were compared with a manufactured zinc-oxide eugenol based root canal sealer, Tubli-seal$^{(R)}$ in terms of water solubility, water sorption, film thickness and microleakage. Solubility and water sorption were determined by the use of the method described in American Dental Association Specification(ADAS) no. 57. Ten samples of each material were prepared into disks 20mm in diameter and 1.5mm in thickness. The samples were immersed in 50ml of distilled water at $37{\pm}1^{\circ}C$ for 7 days. The samples were then removed and placed in a desiccator. The values for solubility and water sorption were calculated using differences between the weights of same sample. Film thickness was determined by the use of the method described in ADAS no. 57 too. A small quantity of mixed cement was placed between two glass plates of which thickness was measured previously. 15Kg loading was applied and total thickness of the glass plates and the cement film was measured. The thickness difference was recorded as the material's film thickness. Microleakage was determined with a dye penetration method. Experimental materials were placed between the dentin surface of bovine tooth and the acrylic rod. These units were immersed in Pelican ink (W-Germany) for three days. Dye-penetrated dentin surfaces of bovine tooth were measured using the NIB Image 1.60 Macintosh program. The results are as follows: 1. Water solubility value of calcium hydroxide-eugenol compound (20.98${\pm}$2.94%) was statistically higher than those of Tubli-seal$^{(R)}$(2.52${\pm}$0.49%)(p<0.05). 2. Water sorption value of calcium hydroxide-eugenol compound (59.72${\pm}$17.75%) was statistically higher than those of Tubli-seal$^{(R)}$(3.15${\pm}$0.76%)(p<0.05). 3. Film thickness value of calcium hydroxide-eugenol compound (0.36${\pm}$0.03mm) was statistically higher than those of Tubli-seal$^{(R)}$(0.12${\pm}$0.1mm)(p<0.05). 4. Dye penetration value after 3 days-immersion of calcium hydroxide-eugenol compound(57.63${\pm}$25.85%) was statistically higher than those of Tubli-seal$^{(R)}$(28.05${\pm}$23.46%)(p<0.05).

  • PDF

The Localization of the Excretory, Purified and Infected Antigenic Protein in the Tissue of Trichinella spiralis Larval Worm (선모충(Trichinella spiralis) 유충의 조직 내 배설, 분리 및 감염항원 단백의 분포)

  • Kim, Soo-Jin;Joo, Kyoung-Hwan;Chung, Myung-Sook;Rho, Young-Bok
    • Applied Microscopy
    • /
    • v.37 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • In order to observe the localization of excretory, purified and infected antigenic protein in the tissue of Trichinella spiralis larvae, immunogoldlabeling methodology using IgG and protein A-gold complex was implemented. T. spiralis larvae obtained from rat muscle were initially cultured in medium, and secreted excretory antigen was collected for 1 or 3 days. Purified antigenic protein was obtained from homogenized T. spiralis larvae. Rabbits were then immunized with 1 or 3 days secreted excretory protein and purified 45 kDa protein, and IgG was purified from collected serum. Serum, against infected antigen, collected from rat on 1 and 4 weeks after infection with T. spiralis larvae, and IgG was purified from collected serum. T. spiralis larvae were embedded in Lowicryl HM20 medium. Then they were finally treated with immunized IgG and protein A-gold complex (particle size; 15 nm) and observed under electron microscope. In T. spiralis larvae tissue, the tissue antigen reacted with rabbit IgC antigen Day 1 secreted excretory protein, infected antigenic protein and purified 45 kDa protein. But different distribution pattern of labeled gold particles were observed. When Day 1 secreted excretoy protein was used, gold particle labeling was observed specifically on the cuticle, basal layer, esophagus interstitial matrix (EIM) and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte of the worm. In a separate group of tissue, the antigen reacted with rabbit IgG against Day 3 secreted excretory protein. Labeled gold particles were specifically distributed on the surface layer of cuticle, EIM and ${\alpha}_0$ granules of stichocyte of the worm. In case of using infected antigenic protein, gold particle labeling was specifically distributed on the cuticle and EIM of the worm. When purifed 45 kDa protein was used gold particle labeling was specifically distributed on the cuticle, basal layer, EIM and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte of the worm. Therefore, excretory antigens appeared to originate from the cuticle and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte for the first day but the cuticle layer associated with globular proteins and ${\alpha}_0$ granules of stichocyte after 3 days and infected antigens appeared to originate from the cuticle for 1 and 4 weeks after infection. These results suggest that excretory and infection specific antigens are secreted into the cuticle, basal layer, EIM and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte and 45 kDa protein may be contained these specific antigens.

Electron Microscopic Study on the Rabbit Inferior Lacrimal Glands (토끼 아래눈물샘의 미세구조에 관한 전자현미경적 연구)

  • Park, Young-Hee;Ahn, E-Tay;Ko, Jeong-Sik;Park, Dae-Kyoon;Kim, Myeong-Soo;Park, Kyung-Ho
    • Applied Microscopy
    • /
    • v.37 no.1
    • /
    • pp.23-33
    • /
    • 2007
  • The lacrimal gland are compound tubule-acinar glands. The main lacrimal function is the production of the aqueous layer, the thickest and major constituent of the precorneal tear film. The lacrimal gland also has an important function in the defense system of the ocular surface, forming a part of the conjunctival-associated hymphoid tissue. The ultrastructural characteristics of the lacrimal gland of the rabbit were described. The lacrimal tissues of rabbits were processed through the conventional techniques for transmission electron microscopy. The secretory portions consisted of three cell types: 1. Serous cells with electron dense secretory granules. 2. Seromucous cells containing variable moderately electron dense secretory granules with flocculent material. 3. Mucous rolls containing mucous secretory granules. The serous cells were situated at the basal portion of acini, and they contained electron dense granules of variable densities and sizes. The seromucous cells contained a few protein secretory granules and more mucous secretory granules. The mucous cells contained even fewer protein secretory granules and exclusively mucous secretory granules. The epithelium of the intralobular ducts showed secretory granules, junctional complexes, and large basolateral intercellular spaces with lateral folds. These study might be helpful in determining inter-relationships, similarities and differences among the orbital glands of various physiological or pathological conditions.

Landscape of Erosional Basin in Korea -In case of land-use changes of hills- (우리 나라 침식분지의 경관 -구릉지의 토지이용 변화를 중심으로-)

  • Son, Myoung-Won
    • Journal of the Korean association of regional geographers
    • /
    • v.6 no.2
    • /
    • pp.83-96
    • /
    • 2000
  • Erosional basins formed in middle and upper reaches of Korean great rivers have been main life space of local small and middle cities, but previous studies on erosional basins are widely apart from residents' life and are in shortage with the endeavor to elucidate the man and environment relationship. This paper analyzes the factors and the modes of land-use changes of hills in the erosional basin. In this paper four erosional basins with different geological conditions are selected to elucidate the effect of geological factor(Geochang: granite, Chogye: metamorphic rock, Angye: gravelly sedimentary rock, Maseong: limestone). And the distribution of land use on the transverse and longitudinal cross-section map of the hill is described. The landscape of erosional basin is consisted of surrounding mountains, hills, dissected valleys, and incoming river's floodplain. Dissected valleys and incoming river's floodplain were reclaimed early as paddy field and hills have been used as woodland up to recently. Residents have a new appreciation of hills as a productive hill out of a traditional holy space[mountain] by influence of capitalistic thought that 'natural environment is a sort of productive resource'. Population increase is the another pressure of hill reclamation. The modes of landscape changes due to natural conditions are as follow: (1) In Geochang basin with dense tectolineament spacing, the gentle part of hill is used as field, orchard and agricultural-industrial complex site and the steep part is as woodland. (2) Hills in Angye basin with sparse tectolineament spacing are relatively flat because of maintaining a part of original denudational surface, and are used as orchids, field, paddy fields and agricultural-industrial complex site. The dissection valleys between hills are gentle concave and are used as paddy fields. (3) Hills in Maseong basin are wide and flat, and are used as fields, orchards, and agricultural-industrial complex site. (4) Because hills in Chogye basin, a closed type, are weared by affluents and are narrow and short. Hills are used as woodland and wide dissected valleys are reclaimed as paddy fields.

  • PDF

A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193 (국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구)

  • Hwang, Hyun Sung;Yun, Eun Young
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The Phoenix-shaped Glass Ewer, which is No. 193 National Treasure, was seriously damaged by a unique form of green glass pieces when excavated among a number of burial accessories of Hwangnamdaechong known to have been formed in the 5th century. While it has long been exhibited at the National Museum of Korea since its treatment for conservation treatment at conservation science laboratory in 1984, the existing adhesive materials seriously deteriorated for the 30 years, and the condition was quite unstable. The epoxy resin used as a restorative materials turned yellowing due to the light and heat so much that it was no longer able to exhibit it in a stable and effective manner. As a result, a re-treatment for conservation was conducted lately. This study focuses on the three pieces of Gold wires used to carefully wrap up the handle of the Phoenix-shaped Glass Ewer broken into three pieces, which has not been studied so far. As for the analysis method for Gold wires, SEM-EDS and Stereo Microscope were used for nondestructive analysis. First of all, the result of the SEM-EDS analysis shows that the composition was Au 91.9 wt.%-Au 92.8 w.t% and Ag 5.9 wt.%-Ag 6.5 wt.%, which indicates that it was an alloy made of Au and Ag. The production technique of Gold wires was also observed by means of optical microscopes. In general, Gold wires were manufactured by a drawing process in which a lump of gold was beaten or pulled out of a hole or by a process of twisting a gold plate. However, Gold wires separated from the handle of the Phoenix-shaped Glass Ewer did not involve any trace of twisting on the surface. Rather, fine vertical stripes were observed with the sections filled up. Hence, it is thought that this Ewer went through a drawing process and then was mended. As a result, no certain relation with the golden mending material used for the Phoenix-shaped Glass Ewer was verified. The findings above indicate that most of the existing researches on Gold wires recognized them, not as separate remains, but merely as a component of other golden remains. Thus, there has been little systematic study on the manufacturing techniques of Gold wires. The future study on Gold wires may verify the correlation between the Gold wires used to fix the handle of the Phoenix-shaped Glass Ewer, which is examined in this study, with that of golden remains in the Silla era.

The Origin and Geochemical Behavior of Fluoride in Bedrock Groundwater: A Case Study in Samseung Area (Boeun, Chungbuk) (화강암 지역 암반 지하수 내 불소 이온의 기원 및 거동: 충북 보은 삼승면 일대의 현장 조사와 실내 실험 연구)

  • Chae, Gi-Tak;Koh, Dong-Chan;Choi, Byoung-Young
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.555-566
    • /
    • 2008
  • Hydrogeochemical study in Samseung area (Boeun, Chungbuk) and waterrock interaction experiment using rock samples from the area were performed to elucidate the fluoride source in groundwater and explaining geochemical behavior of fluoride ion. Fluoride concentration of public water supply mostly using groundwater in Boeun area was significantly higher in South Korea. The maximum fluoride concentration of the study area was 3.9 mg/L, and 23% of samples exceeded the Korean Drinking Water Standard of fluoride (1.5 mg/L). The average concentration of fluoride was 1.0 mg/L and median was 0.5 mg/L. Because of high skewness (1.3), median value is more appropriate to represent fluoride level of this area. The relationships between fluoride ion and geochemical parameters ($Na^+$, $HCO_3$, pH, etc.) indicated that the degree of waterrock interaction was not significant. However, high fluoride samples were observed in $NaHCO_3$ type on Piper's diagram. The negative relationship between fluoride and $NO_3$ ion which might originate from surface contaminants was obvious. These results indicate that fluoride ion in groundwater is geogenic origin. The source of fluoride was proved by waterrock interaction batch test. Fluoride concentration increased up to 1.2 mg/L after 96 hours of reaction between water and biotite granite. However, the relationship between well depth and fluoride ion, and groundwater age and fluoride ion was not clear. This indicates that fluoride ion is not correlated with degree of waterrock interaction in this area but local heterogeneity of fluoriderich minerals in granite terrain. High fluoride concentration in Boeun area seems to be correlated with distribution of permeable structures in hard rocks such as lineaments and faults of this area. This entails that the deep bedrock groundwater discharges through the permeable structures and mixed with shallow groundwater.

Investigation of Rock Slope Failures based on Physical Model Study (모형실험을 통한 암반사면의 파괴거동에 대한 연구)

  • Cho, Tae-Chin;Suk, Jae-Uk;Lee, Sung-Am;Um, Jeong-Gi
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.447-457
    • /
    • 2008
  • Laboratory tests for single plane sliding were conducted using the model rock slope to investigate the cut slope deformability and failure mechanism due to combined effect of engineering characteristics such as angle of sliding plane, water force, joint roughness and infillings. Also the possibility of prediction of slope failure through displacement monitoring was explored. The joint roughness was prepared in forms of saw-tooth type having different roughness specifications. The infillings was maintained between upper and lower roughness plane from zero to 1.2 times of the amplitude of the surface projections. Water force was expressed as the percent filling of tension crack from dry (0%) to full (100%), and constantly increased from 0% at the rate of 0.5%/min and 1%/min upto failure. Total of 50 tests were performed at sliding angles of $30^{\circ}$ and $35^{\circ}$ based on different combinations of joint roughness, infilling thickness and water force increment conditions. For smooth sliding plane, it was found that the linear type of deformability exhibited irrespective of the infilling thickness and water force conditions. For sliding planes having roughness, stepping or exponential types of deformability were predominant under condition that the infilling thickness is lower or higher than asperity height, respectively. These arise from the fact that, once the infilling thickness exceeds asperities, strength and deformability of the sliding plane is controlled by the engineering characteristics of the infilling materials. The results obtained in this study clearly show that the water force at failure was found to increase with increasing joint roughness, and to decrease with increasing filling thickness. It seems possible to estimate failure time using the inverse velocity method for sliding plane having exponential type of deformability. However, it is necessary to estimate failure time by trial and error basis to predict failure of the slope accurately.