Urban Inundation Analysis by Applying with GIS (GIS를 이용한 도시지역 침수해석)

  • Lee, Chang-Hee;Han, Kun-Yeun;Kim, Ji-Sung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.115-126
    • /
    • 2006
  • The purpose of this study is to develop an urban inundation model using GIS(geographic information system). The model is combining a storm sewer system model and a overland-flow model for the estimation inundation depth in urban area caused by the surcharge of storm sewers. SWMM(storm water management model) was employed to resolve the storm sewer flow and to provide the overflow hydrographs caused by the failure of a drainage system due to the shortage of drainage capacity. The level-pool overland-flow model and DEM based overland-flow model were used to calculate the detail inundation zones and depths due to the surcharge on overland surface. The simulation results can help the decision preventing flood damages by redesigning and enlarging the capacities of storm sewer systems in the inundation-prone areas. The model can also be applied to make the potential inundation area map and establish flood-mitigation measures as a part of the decision support system for flood control authority.

  • PDF

A Study on the Calculation of Lateral Flow Pressure of Polluted Soils with Various Water Contents (함수량이 다른 오염지반의 측방유동압 산정에 관한 연구)

  • 안종필;박경호
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.75-88
    • /
    • 2002
  • When unsymmetrical surcharge is worked on polluted soft soils, large plastic shearing deformation such as settlements, lateral displacement, upheavals and shearing failure occured in the soils and they have often done considerable damages to the soils and structures. Accordingly, this study conducts laboratory pilots test to investigate the determination method of lateral flow pressure of polluted soft soils by comparing it to existing equations. The model test is performed that a model stock device is made and polluted soils are filled in a container which fires the soils. Then the displacement is observed as surcharge load is increased by regular intervals at untrained condition. The result shows that test the lateral flow pressure is adequately calculated by the equation (P=K$_{0}$YH) and the maximum value of lateral flow pressure Is found near 0.3H of layer thickness(H) and is higher to ground surface than synthesis pattern, Poulos distribution pattern and soft clay soils(CL, CH) which is not polluted.

A Study on the Lateral Flow in Polluted Soft Soils (오염된 연약지반의 측방유동에 관한 연구)

  • 안종필;박상범
    • The Journal of Engineering Geology
    • /
    • v.11 no.2
    • /
    • pp.175-190
    • /
    • 2001
  • This study investigates the existing theoretical backgrounds in order to examine the behavior of lateral flow according to the plasticity of soils when unsymmetrical surcharge is worked on polluted soft soils by comparing and analyzing the results measured through model tests. Model tests are canied out as follows soil tank, bearing frame and bearing plate are made. By increasing unsymmetrical surcharge to the ground soils with the consistent water content and with gradually increased polluted materials at intervals, the amounts of settlement, lateral displacement and upheaval were respectively observed. In conclusion, the value of critical surcharge was expressed as q$_{cr}$=2.78$_{cu}$ which was similar to those Tschebotarioff(q$_{cr}$=3.0$_{cu}$) and Meyerhof(q$_{cr}$=(B/2H+$\pi$/2)$_{cu}$) had been proposed. The value of ultimate capacity was expressed as q$_{ult}$=4.84$_{cu}$ which was similar to that of Prandtl. The lateral flow pressure is adeQuately calculated by the eQuation(P$_{max}$=K$_o$ r H) and the maximum value of lateral flow pressure is found near O.3H of layer thickness(H) and is higher to ground surface than the ones in composition pattern, Poulos distribution pattern and softclay soils (CL, CH) which is not polluted. The stability control method used in this research followed the management diagram of Tominaga.Hashimoto, Shibata.Sekiguchi, Matsuo.Kawamura who use the amounts of plasticity displacement by lateral flow. As a result, the ultimate capacity values in the diagram {S$_v$-(Y$_m$/S$_v$)} of Matsuo.Kawamura and in the diagram {(q/Y$_m$)-q} of Shibata. Sekiguchi were smaller than in the ones of load-settlement curve (q-S$_v$).

  • PDF

DEM Based Urban Inundation Analysis Model Linked with SWMM (SWMM을 연계한 DEM기반의 도시침수해석 모형)

  • Lee, Chang-Hee;Han, Kun-Yeun;Choi, Kyu-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.441-452
    • /
    • 2006
  • Recently the natural damage associated with flood disaster has been dramatically increased. Especially, inundation in the urban area causes serious damage to people and assets because of the concentration of infrastructure and population growth. The purpose of this study is to develop a new urban inundation model combining a storm sewer system model and a 2D overland-flow model for the estimation inundation depth In urban area caused by the surcharge of storm sewers. The movement of water in the studied urban watershed is characterized by two components, namely, the storm sewer flow component and the surcharge-induced inundation component. The model was applied to Goonja and Jangan catchments. Inundated depths were presented to demonstrate model simulation results. The simulation results can help the authority decide preventing flood damages by redesigning and enlarging the capacities of storm sewer systems in the inundation-prone areas. The model can also be applied to make the potential inundation area map and establish flood-mitigation measures as a part of the decision support system for flood control authority.

The Stability of Bridge Abutment Reinforced by Pile-slab on Soft Ground Undergoing Lateral Flow (측방유동 연약지반상 파일슬래브로 보강된 교대의 안정)

  • Hong, Won-Pyo;Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.13-24
    • /
    • 2006
  • A site investigation has been performed for bridge abutments constructed on soft ground, which are deformed laterally by backfill. As the result from the evaluation of lateral movement in bridge abutment, the foundation piles were not considered as the passive pile at the design stage and the period for soft ground improvement was not proper. In order to prevent lateral movement of bridge abutment, the pile slab is proposed as a countermeasure. This method can effectively prevent the lateral flow of soft ground, since the overburden surcharge due to backfill on soft ground would be effectively delivered to bedrock through the piles in soft ground. The instrumentation system is designed and installed to investigate the behavior of bridge abutment on soft ground reinforced by pile slab. The instrumentation results show that pile slab effectively resists to the lateral movement of bridge abutment due to backfill. Also, the surcharge loads due to backfill are transmitted to the bedrock through piles. It confirms that the pile slab effectively resists to the lateral movement of bridge abutment due to backfill and the applied design method is reasonable.

Fatigue Effect and Particle Rearrangement of Geosynthetics Filter Layer with Cyclic Flow Conditions (교번흐름 조건에 따른 토목섬유 필터층의 재료분리 및 지오텍스타일의 피로영향 분석)

  • Oh, Young-In;Yoo, Jeon-Yong;Kim, Hyun-Tae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1554-1561
    • /
    • 2005
  • Geotextiles form one of the two largest groups of geosynthetics and it is consisted two major types of synthetic material (Woven, Non-woven). The functions of geotextiles are separation, reinforcement, filtration, drainage and as a moisture barrier. Within these functions, however, there are a large number of applications or use areas. Although the many research scholar and engineer developed and established the design criteria and construction methodology of geosynthetics filter layer, because the lack of suitable design terminology and uncertainty of long term durability, sustainable research still needed for optimum design methodology to the complicate field conditions. Especially, more intensive research needed about under the cyclic flow condition and fine silty sand base material. In this paper, the filter model test performed under cyclic flow with various boundary conditions (period and frequency of cyclic flow, types of geosynthetic filter material, surcharge etc.).

  • PDF

A Study on the Stability Control Method of Soft and Polluted Silt Soils (연약한 실트지반과 오염된 실트지반의 안정관리 방법에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.5-16
    • /
    • 2008
  • This study investigated the existing theoretical backgrounds in order to examine the stability control method of lateral flow caused by the Plasticity of soils when unsymmetrical surcharge works on polluted soils and then compared and analyzed the results measured through model tests. Ultimate bearing power of ML and $ML_{p1}$ and $ML_{p2}$ obtained at surcharge(q)-settlement$(S_v)$ curve showed similar trends to ultimate bearing power obtained from control chart of deflection $(S_v-Y_m)$ by Tominaga.Hashimoto, that of $S_v-(Y_m/S_v)$ by Matsuo.Kawamura and that of $(q/Y_m)-q$ by Shibata.Sekiguchi and so it is considered that it has no problem in actual applicability. ${S_v-(Y_m/S_v)}$ of control chart of $ML_{p1}$ by Matsuo.Kawamura showed smaller value than ultimate bearing capacity value from surcharge-settlement curve $(q-S_v)$. Expression of ML of fracture baseline at stability control charge by Matsuo Kawamura is ${S_v=3.21exp}\{-0.48(Y_m/S_v)\}$ and expression of $ML_{p1}$ is ${S_v=3.26exp}\{-0.96(Y_m/S_v)\}$ and expression of $ML_{p2}$ is ${S_v=6.33exp}\{-0.45(Y_m/S_v)\}$.

Analysis of Stress Transfer Mechanism of SCP-Reinforced Composite Ground (SCP 복합지반의 응력전이거동 해석)

  • Kim, Yun-Tae;Park, Hyun-Il;Lee, Hyung-Joo;Kim, Sang-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.227-234
    • /
    • 2004
  • Sand compaction pile (SCP) method is composed of compacted sand pile inserted into the soft clay deposit by displacement method. SCP-reinforced ground is composite soil which consists of the SCP and the surrounding soft soil. When a surcharge load is applied on composite ground, time-dependent behavior occurs in the soft soil due to consolidation according to radial flow toward SCP and stress transfer also takes place between the SCP and the soft soil. This paper presents the numerical results of cylindrical composite ground that was conducted to investigate consolidation characteristics and the stress transfer mechanism of SCP-reinforced composite ground. The results show that the consolidation of soft clay has a significant effect on the stress transfer mechanism and stress concentration ratio of composite ground

  • PDF

Experimental Study on Soft Ground with DCM Column (DCM 타설 지반에 관한 실내모형실험)

  • Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.3
    • /
    • pp.35-44
    • /
    • 2020
  • This study described the result of laboratory model tests, in order to compare the improvement effect of the DCM column installed on the soft ground according to DCM column type. In the laboratory model test, the non-reinforced type and the 3 types of DCM column were applied, and the behavior (settlement, lateral flow) of soft ground was evaluated under the surcharge load condition for each type. The settlement evaluation result showed that the settlement of soft ground without DCM column occurred rapidly under the low load condition, but the settlement of the soft ground with the DCM column had relatively small settlement. The evaluation result of lateral flow in the soft ground showed that the soft ground with DCM column had lower lateral displacement than the soft ground without DCM column. Especially, the lateral displacement under the same load condition decreased in the order of pile type, wall type, and grid type. Therefore, it confirmed that the improvement effect of soft ground was excellent when the DCM of grid type was applied for settlement and lateral flow.

Development of Urban Inundation Analysis Model Using Dual-Drainage Concept (Dual-Drainage 개념에 의한 도시침수해석모형의 개발)

  • Lee, Chang Hee;Han, Kun Yeun;Noh, Joon Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4B
    • /
    • pp.379-387
    • /
    • 2006
  • An urban inundation model coupling an one-dimensional stormwater model, SWMM(Storm Water Management Model), and a two-dimensional inundation model was developed to simulate inundation caused by the surcharge of storm sewers in urban areas. The limitation of this model which can not simulate the interaction between drainage systems and surcharged flow was resolved by developing Dual-Drainage inundation analysis model which was based upon hydraulic flow routing procedures for surface flow and pipe flow. The Dual-Drainage inundation analysis model can simulate the effect of complex storm drainage system. The developed model was applied to Dorim, catchment. The computed inundated depth and area have good agreement with the observed data during the flood events. The developed model can help the decision support system of flood control authority for redesigning and constructing flood prevention structures and making the potential inundation zone, and establishing flood-mitigation measures.