• Title/Summary/Keyword: support parameters

Search Result 1,391, Processing Time 0.024 seconds

Uniformly Minimum Variance Unbiased Estimation for Distributions with Support Dependign on Two Parameters

  • Hong, Chong-Sun;Park, Hyun-Jip;Lee, Chong-Cheol
    • Journal of the Korean Statistical Society
    • /
    • 제24권1호
    • /
    • pp.45-64
    • /
    • 1995
  • When a random sample is taken from a certain class of discrete and continuous distributions whose support depend on two parameters, we could find that there exists the complete and sufficient statistic for parameters which belong to a certain class, and fomulate the uniformly minimum variance unbiased estimator (UMVUE) of any estimable function. Some UMVUE's of parametric functions are illustrated for the class of the distribution. Especially, we find that the UMVUE of some estimable parametric function from the truncated normal distribution could be expressed by the version of the Mill's ratio.

  • PDF

유한요소해석과 다구찌법을 이용한 구명정 진수장치 설계인자 결정에 관한 연구 (A study to determine the design parameters of Lifeboat Davit by Using FEM and Taguchi Method)

  • 최주형;안정철;김정환;유찬욱;최영삼
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.554-559
    • /
    • 2010
  • 구명정 진수장치는 크게 main frame, main arm, upper arm, support bar로 구성되어 있다. 본 논문에서는 upper arm의 굽힘 강성에 영향을 주는 인자로 plate 두께와 arm 단면의 가로 세로 길이를 설계 인자로 설정하며, 이들 인자에 대한 영향력을 분석하고자 하였다. 설계 인자에 대한 영향력 분석을 위해 실험계획법의 일종인 다구찌법과 함께 수치해석적인 방법을 이용하였으며, 각 설계인자간의 영향력 분석을 통해 실질적으로 산업에 도움을 주고자하였다.

진동데이터 적용 모델기반 이상진단 (Model-based Fault Diagnosis Applied to Vibration Data)

  • 양지혁;권오규
    • 제어로봇시스템학회논문지
    • /
    • 제18권12호
    • /
    • pp.1090-1095
    • /
    • 2012
  • In this paper, we propose a model-based fault diagnosis method applied to vibration data. The fault detection is performed by comparing estimated parameters with normal parameters and deciding if the observed changes can be explained satisfactorily in terms of noise or undermodelling. The key feature of this method is that it accounts for the effects of noise and model mismatch. And we aslo design a classifier for the fault isolation by applying the multiclass SVM (Support Vector Machine) to the estimated parameters. The proposed fault detection and isolation methods are applied to an engine vibration data to show a good performance. The proposed fault detection method is compared with a signal-based fault detection method through a performance analysis.

교차검증을 이용한 SVM 전력수요예측 (SVM Load Forecasting using Cross-Validation)

  • 조남훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.485-491
    • /
    • 2006
  • In this paper, we study the problem of model selection for Support Vector Machine(SVM) predictor for short-term load forecasting. The model selection amounts to tuning SVM parameters, such as the cost coefficient C and kernel parameters and so on, in order to maximize the prediction performance of SVM. We propose that Cross-Validation method can be used as a model selection algorithm for SVM-based load forecasting technique. Through the various experiments on several data sets, we found that the difference between the prediction error of SVM using Cross-Validation and that of ideal SVM is less than 5%. This shows that SVM parameters for load forecasting can be efficiently tuned by using Cross-Validation.

한약재 추출물 함유 앰플의 주름개선 효능에 관한 기초 임상연구 (The Efficacy of Ampule Containing Herbal Extract for Improving Skin Wrinkles in Women)

  • 도은주;이진상;박현진;하일도;김영철;김미려
    • 대한한의학방제학회지
    • /
    • 제17권2호
    • /
    • pp.111-121
    • /
    • 2009
  • Objectives : This study was performed to evaluate the efficacy of ampule containing herbal extract(Ulmus davidiana, Ginkgo biloba, Perilla ocymoides, Morus alba, Glycyrrhiza uralensis (licorice), and Angelica gigas) on skin wrinkles in adult women with facial wrinkles. Methods : A total of 12 women, 30 to 46 years of age, with wrinkles in the corner of eyes, applied ampule containing herbal extract twice daily for up to 12 weeks. Silicon replicas of right crow's feet area and antecubital fossa were taken before use of test product and at 4, 8 and 12 weeks. The replicas were analyzed by optical profilometry with Skin Visiometer SV600. The wrinkle and roughness parameters, R1, R2, R3, R4 and R5 were calculated and statistically analyzed. In addition, a subjective evaluation of product efficacy was conducted by patient's assessment. Results : The mean values of all the skin roughness parameters were decreased at 4-week, and decreased significantly at 8 and 12-week except R4 at 12-week after test product use. The subjective evaluation of wrinkle by patient's assessment was also improved. However, one patient noted stiffness of face after use of test product. Conclusions : These study suggested that the application of ampule containing herbal extract twice daily for 12 weeks may effectively improve the facial wrinkles without severe side effect.

  • PDF

대곡면 후곡판 성형을 위한 블랭크 지지구조의 적합성 연구 (A Compatibility Study on Blank Support Structure for Large and Curved Thick Plate Forming)

  • 임미래;곽봉석;강범수;구태완
    • 소성∙가공
    • /
    • 제28권6호
    • /
    • pp.335-346
    • /
    • 2019
  • Thick plate forming is presented to manufacture a large and curved member of steam turbine diaphragm. Due to three-dimensional asymmetry of target geometry, it is hard to consistently keep the blank position in die cavity between forming punch and die. In order to relieve the position instability of the blank during the thick plate forming, a blank support structure is proposed to be composed of guide pins and linear bearing, and blank guide arm enlarged from both longitudinal ends of the thick blank. In this study, parametric investigations with regard to the geometric position and width of the blank guide arm are carried out. As main geometric parameters, 2 positions such as maximum curvature region and minimum one on a curved cross-section profile of the target shape are selected, and 14 widths of the blank guide arm are considered. Using 28 variable combinations, three-dimensional numerical simulations are performed to predict the appropriate range of the process parameters. The compatibility and validity of the blank support structure with the blank guide arm for the thick plate forming is verified through the thick plate forming experiments.

다구찌 실험 계획법을 활용한 평삭 가공에서의 표면 거칠기에 대한 절삭조건 영향 분석 (Effects of Cutting Parameters on Surface Roughness in Planing Using Taguchi Method)

  • 서동현;권예필;김영재;최환진;전은채
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.93-98
    • /
    • 2021
  • The complex effects of the machining parameters make it is difficult to control and predict surface roughness. The theoretical surface roughness observed during mechanical machining with a round tool is determined by the tool radius and pitch. However, it was revealed that other parameters, such as the depth of cut and cutting speed, also affect surface roughness. This study adapted the Taguchi method, which can analyze the effects of cutting parameters quantitatively with an efficient number of experiments, to optimize the parameters for better surface roughness. Experiments were designed based on an orthogonal array, and the quantitative effects on the surface roughness were analyzed using the S/N ratio. The surface roughness was affected by all parameters, especially the tool radius. The optimum cutting parameter values obtained in this study showed better surface roughness than the other combinations of the parameters.

Influence of loading and unloading of hydraulic support on the caving property of top coal

  • Huayong Lv;Fei Liu;Xu Gao;Tao Zhou;Xiang Yuan
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.103-111
    • /
    • 2023
  • The caving property of top coal is a key factor to the success of top coal caving mining. The influence law of cyclic loading and unloading of hydraulic support on top coal caving is of great significance to improve the recovery rate of top coal. The similar simulation methods were used to study the dynamic evolution of the top coal cracks under the multi-cycle action of the support, and the parameters of top coal cracks were analyzed quantitatively in this paper. The results show that the top coal cracks can be divided into horizontal cracks and vertical cracks under the cyclic loading and unloading of the support. With the increase of the times of the support cycles loading and unloading, the load on the support decreases, the fractal dimension of the cracks increases, the number and total length of the top coal cracks increases, and the top coal caving is getting better. With the increase of the times of multi-cycle loading and unloading, the fractal dimension, total crack length and crack rate of top coal show a trend of rapid increase first and then increase slowly. Both the total length of the top coal cracks and the crack rate basically show linear growth with the change of the fractal dimension. The top coal caving can be well improved and the coal resource recovery rate increased through the multi-cycle loading and unloading.

팔걸이가 편마비환자의 보행에 미치는 영향 (Effect of an Arm Sling on Gait with Hemiparesis)

  • 송근호;이현옥
    • The Journal of Korean Physical Therapy
    • /
    • 제18권4호
    • /
    • pp.27-40
    • /
    • 2006
  • Purpose: This study was to investigate the effect of an arm sling on gait with hemiparesis. Methods: Fifteen patients(8 male, 7 female) with hemiparesis participated in this study and walked self-selected speed over 10m walkway, randomly without arm sling, with Single strap hemisling and Rolyan humeral cuff sling. It were filmed by 5 video camera and used with 3-dimensional motion analyzer system. The following gait variables were analyzed: temporo-spatial parameters, kinematic parameters. Results: In the comparison of temporo-spatial parameters each trial, walking velocity and single support time on affected side was significantly increased and step length on affected side, step length asymmetry ratio, single support time asymmetry ratio was significantly decreased in the Single strap hemisling and Rolyan humeral cuff sling. In the comparison of kinematic parameters each trial, maximal angle of the hip flexion on affected side was significantly increased in the Single strap hemisling and Rolyan humeral cuff sling and maximal angle of the knee flexion on affected side was significantly increased in the Rolyan humeral cuff sling and maximal angle of the ankle dorsiflexion on affected side was significantly increased in the Single strap hemisling. Conclusion: An arm sling improved walking velocity and decreased asymmetry and increased maximal angle of hip, knee, ankle flexion on affected side with hemiparesis caused by stroke.

  • PDF

The Effects of Insoles for Postural Correction on Spatial-temporal Changes of Gait in Spastic Cerebral Palsy Children

  • Kim, Hee Tak;Lim, Sang Wan
    • 국제물리치료학회지
    • /
    • 제6권2호
    • /
    • pp.840-845
    • /
    • 2015
  • Improvement in functional gait is one of treatment goals in treatment of cerebral palsy children. This study intended to examine the effects of insoles for postural correction on gait in spastic cerebral palsy patients by investigating changes in gait temporal spatial parameters. As the subjects, 15 spastic bilateral cerebral palsy patients participated in this study. Temporal spatial parameters of gait were measured using GAITRite system under three gait conditions. Bare foot gait, gait in shoes, and gait in insoles for postural correction were conducted. In order to look at differences in temporal spatial parameters according to three gait conditions, repeated one way analysis of variance was conducted. As post hoc test, Bonferroni was conducted. A significant level was set at ${\alpha}=.05$. According to the result of this study, gait velocity, cadence, step length, stride length of the left lower extremity significantly changed. When the subjects put on customized insoles for postural correction, the effect was greatest. There were no significant changes in stance time, single support time, double support time, swing % of gait, and stance % of cycle. Therefore, gait with insoles for postural correction positively influenced functional gait improvement and will be able to be usefully employed for spastic cerebral palsy children as one of gait assistance devices.