• Title/Summary/Keyword: supplying water

Search Result 317, Processing Time 0.036 seconds

The AQR Control in the SCADA System of Manless Power Plant (무인발전소 SCADA SYSTEM 에서의 AQR 제어 운영)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Kim, Ki-Won;O, Seok-Yeong;Choi, Hyeong-Cheol;Lee, Nam-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.58_59
    • /
    • 2009
  • Generator excitation system, supplying the voltage to power system, is controlled by various manners as aspects of power system. Previously excitation systems mainly used AVR(Automatic Voltage Regulator) and FCR(Field Current Regulator) to control voltage, but nowadays the excitation systems have the tendency to adopt AQR(Automatic Reactive power Regulator) and APFR(Automatic Power Factor Regulator) to do it so as to get into step with diverse requirements of power system and high digital technology. This paper presents which operation methods is effective for the equipment, according to increase the unmanned power station thanks to automation technic.

  • PDF

A Study on the Internal Structure of Heumgyeonggaknu

  • Kim, Sang Hyuk;Lee, Yong Sam;Lee, Min Soo;Ham, Sun Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • Heumgyeonggaknu is a water-hammering type automatic water clock which was made by Jang Yeong-Sil in 1438. The water clock that is located in Heumgyeonggaknu consists of Suho which is equipped with 2-stage overflow. Constant water wheel power is generated by supplying a fixed amount of water of Suho to Sususang, and this power is transferred to each floor at the same time. The 1st floor rotation wheel of Gasan consists of the operation structure which has the shape of umbrella ribs. The 2nd floor rotation wheel is made so that the 12 hour signal, Gyeong-Jeom signal, and Jujeon constitute a systematic configuration. The 3rd floor rotation wheel is made so that the signal and rotation of Ongnyeo and four gods can be accomplished. Based on the above conceptual design, this paper analyzed the internal signal generation and power transmission of Heumgyeonggaknu.

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Analysis of the Water Quality by Various Gate Operation Effects at Nakdong Estuary Barrier (낙동강하구둑 수문운영에 따른 수질 영향 분석)

  • Lee, Sang Jin;Ryoo, Kyong Sick;Hwang, Man Ha;Lee, Sang Uk
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.651-658
    • /
    • 2008
  • Estuary barrier is a hydraulic structure constructed to supply safely water as protecting chlorine penetration of sea water. However, the barrier brings about a problem which decreases original functions of estuary because hydraulic ecology was disrupted as obstructing natural water exchange between fresh water and sea water. It is important to supply Enough fresh water in the estuary ecosystem. But it is possible to reduce the problems brought from barrier throughout efficient water gate operation of estuary barrier. It was shown in this study that the environmental effect of estuary in Nakdong river was investigated according to the control of water level. Also, the basic information about the effective water gate operation was provided. The analysis results showed that the release rate of estuary was increased about 20% as changing the operational water levels. This helps supplying fresh water durably to the mixing zone. Also, CE-QUAL-W2 model was utilized to assess water quality. The values of BOD and COD were not changed in estuary area. From the result, it was analyzed the effect of water quality according to the water gate operation was not indicated.

Freezing and Melting Phenomena of Urea-water Solution for Diesel Vehicle SCR System (디젤차량 SCR 시스템용 요소수용액의 동결과 해동 현상)

  • Choi, B.C.;Seo, C.K.;Myong, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2009
  • Urea-SCR system, the selective catalytic reduction using urea as reducing agent, is a powerful technique to reduce nitrogen oxides(NOx) emitted from diesel engines. However, a tank of urea(32.5 wt%)-water solution can be frozen in low ambient temperature levels of below $-11^{\circ}C$. The purpose of this study is to understand freezing and melting phenomena of the urea-water solution, and its can be applied to get the urea-water solution from frozen it within 5 minutes after cold start. Factors considered were the type of heater and the urea tank shape. From the results, it was found that melting volume of cartridge heater B during 5 minutes of heating period was 83ml when supplying electric power of 150W. Horizontal heater B, which was put in the narrow bottom space of the tank T1, had fast melting characteristics.

  • PDF

A Study on the Practical Use Status of Cold & Hot Water Supply System in High-rise Residential Buildings (고층 주거건물 급수$\cdot$급탕설비의 사용실태에 관한 조사연구)

  • Seok Ho-Tae;Kim Jang-Han;Cha Min-Chul;Cho Kyung-Jae;Yeo Myoung-Souk
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.75-82
    • /
    • 2005
  • The High-rise Residential Buildings are recently consuming a lot of energy because of the vertical height rise in case of supplying cold and hot water. It is required to a appropriate solution in occurring discomfortable use and unexpected conditions of High-rise Residential Buildings on account of the difference of water supply pressure on top and bottom floor, faucet outlet pressure rise. Thus, the purpose of this study is to research on practical use status of Cold and Hot Water Supply System through Question Survey in High-rise Residential Buildings and to analyze problems.

Effect of pH and Iron/Manganese Ion on TiO2 Mediated Photocatalytic Inactivation of Index Microorganisms (LNAPL을 이용한 지중 산소전달 향상: (I) Abiotic Condition)

  • Ha, Jeong-Hyub;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.307-311
    • /
    • 2004
  • The objective of this work is to evaluate the hypothesis that a good technique for supplying oxygen to the saturated zone in the presence of light nonaqueous phase liquid (LNAPL) pool contamination at the water table is to pass air through the unsaturated zone above the pool. This hypothesis was evaluated in experimental studies performed using a bench-scale, sand-tank reactor, Steady-state abiotic experiments in the sand-tank reactor with air flowing through the reactor headspace demonstrated that oxygen supply through the water table interface into the saturated zone was enhanced when an LNAPL (dodecane) pool was present at the water table. These experimental results confirmed the hypothesis that an LNAPL pool can serve as a high concentration oxygen source to the oxygen-limited area beneath the pool and, as a result, enhance the in situ biodegradation rate.

An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model (KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究))

  • Ryu, Tae-Sang;Cheong, Tae-Sung;Ko, Ick-Hwan;Ha, Sung-Ryong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

Variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area (유역배율에 따른 저수지의 하천유지용수 공급량)

  • Noh, Jae-Kyoung;Lee, Jae-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.331-341
    • /
    • 2011
  • To provide variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area, 8 reservoirs were selected to draw operation rule curve and to analyze water supplies from reservoirs. Reliability of 90% for supplying irrigation water from reservoir was able to maintain and instream flow water was able to be supplied only in the reservoir with magnification of paddy irrigation area to watershed area above 3. The more magnification of paddy irrigation area to watershed area increased, the more ratio of irrigation water to total water storage decreased, and the more ratio of instream flow water to total water storage increased. From the heightening 113 reservoirs in Korea, annual irrigation water was estimated to 1,146.05 $Mm^3$ in normal operation, 839.57 $Mm^3$ in withdrawal limited operation, and annual instream flow water was estimated to 149.68 $Mm^3$ in normal operation, 283.19 $Mm^3$ in withdrawal limited operation. It was concluded that withdrawal limited operation was followed to have the premise of saving irrigation water, more instream flow water was able to be supplied from reservoirs with high magnification of paddy irrigation area to watershed area.

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.