• Title/Summary/Keyword: supply pipe

Search Result 389, Processing Time 0.025 seconds

Identification on Principle of Acoustic Wave Propagation Characteristics in a Gas Pipe (가스 배관 내부의 음파 전달 특성에 관한 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.797-804
    • /
    • 2008
  • In the gas supply pipe, the gas leakage caused by the impact of the construct equipment is serious problem. The identification of the impact position is an important issue and an engineering work. For the basic research of this problem, the principle studies for the acoustic wave propagation in a gas pipe are proceeded in this paper. This principal work is based on the identification of the cut-off frequency associated with major modes of the gas pipe theoretically and experimentally The cut-off frequency is confirmed by STFT and cross-correlation function is used to identify the leakage position.

Development of a Robot System for Monitoring and Repairing a Underground Pipe (지하매설 배관의 탐사 및 도장을 위한 로봇시스템 개발)

  • Yeo, Hee-Joo;Sung, Mun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.346-348
    • /
    • 2007
  • Underground pipe is an instrument to transport rapidly and safely a lot of fluid like gas, oil, water supply and drain system. It acts like blood vessels of human body in a modern industry. As in this country, the pipe facilities have been constructing since 1970's. The pipes constructed for a long time ago are already starting to reveal the problem like corrosion and most of them are built underground. So for companies, the managing of the underground pipes is very hard because it needs high technology and a lot of money. So we made a new robot system to repair and maintain the pipes at a low price. This new robot is devised using pressing wall type to work inside 700${\sim}$900(mm) size pipe. And it has good carrying and working power.

  • PDF

OPTIMAL DESIGN FOR CAPACITY EXPANSION OF EXISTING WATER SUPPLY SYSTEM

  • Ahn, Tae-Jin;Lyu, Heui-Jeong;Park, Jun-Eung;Yoon, Yong-Nam
    • Water Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.63-74
    • /
    • 2000
  • This paper presents a two- phase search scheme for optimal pipe expansion of expansion of existing water distribution systems. In pipe network problems, link flows affect the total cost of the system because the link flows are not uniquely determined for various pipe diameters. The two-phase search scheme based on stochastic optimization scheme is suggested to determine the optimal link flows which make the optimal design of existing pipe network. A sample pipe network is employed to test the proposed method. Once the best tree network is obtained, the link flows are perturbed to find a near global optimum over the whole feasible region. It should be noted that in the perturbation stage the loop flows obtained form the sample existing network are employed as the initial loop flows of the proposed method. It has been also found that the relationship of cost-hydraulic gradient for pipe expansion of existing network affects the total cost of the sample network. The results show that the proposed method can yield a lower cost design than the conventional design method and that the proposed method can be efficiently used to design the pipe expansion of existing water distribution systems.

  • PDF

High-Temperature Heat-Pipe Type Solar Thermal Receiver (고온용 히트파이프형 태양열 흡수기)

  • Boo, Joon-Hong;Jung, Eui-Guk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.668-671
    • /
    • 2007
  • A numerical study was conducted on a simplified model of a high-temperature solar receiver which incorporates liquid-metal heat pipe. The objective of this paper is to compare the isothermal characteristics of the heat pipe receiver with the conventional receiver utilizing convection of molten salt as heat carrier. The solar receiver was assumed to be subject to a concentration ratio between 50 and 1,000 to supply high-temperature heat to a stirling engine for electric power generation. For simplicity of the analysis, a cylindrical geometry was assumed and typical dimensions were used based on available literature. The heat pipe had a shape of double-walled cavity and the working fluid was a sodium. The analysis was performed assuming that the radiation heat flux on the inner walls of the receiver was uniform, since the focus of this study was laid on the comparison of the conventional type and heat pipe type receiver. The results showed that the heat pipe type exhibited superior performance when the operating temperature becomes higher. In addition, to explore the advantage of the heat pipe receiver, the channel shape and dimensions should be adjusted to increase the heat transfer area between the wall and the heat trnasfer medium.

  • PDF

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

The Study on the Effect of Interfirm Collaboration On Logistics Performance in Supply Chain -Focusing on the Steel Pipe Industry- (공급사슬에서의 기업 간 협력이 물류성과에 미치는 영향에 관한 연구)

  • Choi, Soo-Hyung;Choi, Jin-Hyeug
    • Management & Information Systems Review
    • /
    • v.30 no.4
    • /
    • pp.229-251
    • /
    • 2011
  • This paper will discuss the significance of cooperation between supply chain companies and its components. In addition, it will analyze how this effects the outcome in distribution focusing on companies in the steel pipe industry. In sum, theory 1 was chosen since as a result of hierarchical regression analysis communication, IT, partnership, and success monitoring, which are all components of the supply chain cooperation, are proven to affect the absolute distribution success positively. According to the standardized beta coefficient the most important factor for distribution success is communication, followed by IT, partnership and lastly success monitoring. Moreover, according to theory 2, communication, IT, partnership and success monitoring all affect relative distribution success positively. Most important factors are communication, IT, partnership, success monitoring. Thus, since the most crucial factor in deciding both the absolute and relative distribution success is communication, steel pipe companies are advised to execute strategic use.

  • PDF

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

Characteristics of Structural Behavior of Unplasticized Polyvinyl Chloride (PVC-U) Pipe Buried Underground (지중매설 경질폴리염화비닐관의 구조적 거동)

  • Kim, Sun-Hee;Cheon, Jinuk;Kim, Eung-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.16-23
    • /
    • 2015
  • The industrialization and urbanization forced to increase the density of pipelines such as water supply, sewers, and gas pipelines. The materials used for the existing pipe lines are mostly composed of concretes and steels, but it is true that the development for more durable and efficient materials has been continued performed to produce long lasting pipe lines. Recently, underground pipes serve in diverse applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. In this paper, we present the result of investigation pertaining to the structural behavior of unplasticized polyvinyl chloride (PVC-U) flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, pipe stiffness, 4-point bending test, experimental and analytical studies are conducted. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is about 8% although there are significant variations in the mechanical properties of the pipe material. In addition, it was found by the 4-point bending test there is no problem in the connection between the pipes by coupler.

Heat Flux Calculation for Thermal Equilibrium of Cofferdam in a LNG Carrier (LNG선 Heating Coil의 설계를 위한 Cofferdam내 열정산)

  • Joo-Ho Heo;Young-Bum Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.1
    • /
    • pp.98-106
    • /
    • 1998
  • This paper shows the temperature distribution of double hull compartment and of cofferdam in a large LNG Carrier. In LNG Carrier, due to the lower cargo temperature($-163^{\circ}C$), structures are forced to lose their strength if additional heat is not supplied. So it is very important to estimate the temperature distribution and the heat flux needed to maintain the structure properly. The temperature of each compartment is obtained using 2-dimensional model analysis and compared with 3-dimensional results. And also this paper gives preliminary estimation of pipe length to supply necessary heat flux in bare pipe and finned pipe.

  • PDF