• Title/Summary/Keyword: supervisory control system

Search Result 262, Processing Time 0.025 seconds

Validation of the Eddy Viscosity and Lange Wake Models using Measured Wake Flow Characteristics Behind a Large Wind Turbine Rotor (풍력터빈 후류 유동특성 측정 데이터를 이용한 Eddy Viscosity 및 Lange 후류모델의 예측 정확도 검증)

  • Jeon, Sang Hyeon;Go, Young Jun;Kim, Bum Suk;Huh, Jong Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • The wake effects behind wind turbines were investigated by using data from a Met Mast tower and the SCADA (Supervisory Control and Data Acquisition) system for a wind turbine. The results of the wake investigations and predicted values for the velocity deficit based on the eddy viscosity model were compared with the turbulence intensity from the Lange model. As a result, the velocity deficit and turbulence intensity of the wake increased as the free stream wind speed decreased. In addition, the magnitude of the velocity deficit for the center of the wake using the eddy viscosity model was overestimated while the turbulence intensity from the Lange model showed similarities with measured values.

A Fuzzy Model Based Controller for the Control of Inverted Pendulum

  • Wook Chang;Kwon, Ok-Kook;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.459-464
    • /
    • 1998
  • In this paper, we propose a stable fuzzy logic controller architecture for inverted pendulum,. In the design procedure, we represent the fuzzy system as a Takagi-Sugeno fuzzy model and construct a global fuzzy logic controller by considering each local state feedback controller and a supervisory controller, Unlike usual parallel distributed controller, one can design a global stable fuzzy controller without finding a common Lyapunov function by the proposed method. A simulation is performed to control the inverted pendulum to show the effectiveness and feasibility of the proposed fuzzy controller.

  • PDF

Applying Asymmetric Key Encryption to Secure Internet based SCADA

  • Robles, Rosslin John;Kim, Tai-hoon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.4 no.2
    • /
    • pp.17-21
    • /
    • 2012
  • As an acronym for Supervisory Control and Data Acquisition, SCADA is a concept that is used to refer to the management and procurement of data that can be used in developing process management criteria. The use of the term SCADA varies, depending on location. Conventionally, SCADA is connected only in a limited private network. In current times, there are also demands of connecting SCADA through the internet. The internet SCADA facility has brought a lot of advantages in terms of control, data generation and viewing. With these advantages, come the security issues regarding web SCADA. In this paper, we discuss web SCADA and its connectivity along with the issues regarding security and suggests a web SCADA security solution using asymmetric-key encryption.

Method for Acquisition of Network Analysis Data under Inferior SCADA Signal Quality Conditions (원격 장치 신호 품질 불량 시 계통해석 데이터 취득 방안)

  • Bae, Ae-Kyoung;Kim, Young-In;Kim, Hong-Joo;Lee, Seung-Ju;Lee, Seok-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.288-289
    • /
    • 2015
  • EMS(Energy Management System: 에너지 관리 시스템)에서 SCADA(Supervisory Control and Data Acquisition: 집중원격감시 시스템)은 RTU(Remote Terminal Unit), RCC(Remote Control Centre) 등을 통해 데이터를 취득한다. 이렇게 취득된 데이터는 토폴로지(Topology)를 구성하고, 계통을 감시하고 해석하는데 사용된다. EMS에서 계통해석 기술은 발전, 송전, 변전, 배전 계통이 유기적으로 결합되어 원활한 전력의 공급과 높은 신뢰도를 제공할 수 있어야 하는데 이를 위해서는 항상 신뢰할 수 있는 데이터를 사용해야 한다. 하지만 SCADA 취득 데이터는 통신 선로 상의 지연 등 통신 오류를 포함하고 있기 때문에 항상 신뢰할 수는 없으며, 오차를 포함한 측정 데이터를 사용하여 계통 해석을 할 경우 계통 해석 결과 전체를 신뢰할 수 없게 된다는 문제점이 있다. 본 논문에서는 원격 장치 신호 품질 불량 시 계통해석 데이터를 보다 신뢰할 수 있도록 취득, 사용하는 방안에 대해 제안한다.

  • PDF

Modeling of CPC/COLSS for YGN#3,4 simulator (영광#3,4호기 시뮬레이터의 노심보호 및 감시계통 모델링)

  • Kim, Dong-Uk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.400-405
    • /
    • 1998
  • 본 논문에서는 한국형 원자력 발전소의 기준모델인 영광 3,4호기 운전원 훈련용 시뮬레이터의 모델링 절차와 ABB-CE 원전의 독특한 계통인 CPC/COLSS (Core protection Calculator/Core Operating Limit Supervisory System) 계통에 대한 모델링을 전개허고 있다. CPC/COLSS는 원자로를 포함하는 냉각재계통(NSSS)과 핵연료의 건전성을 보장하기위한 계통으로서 감시및 보호 과정에서의 계산을 디지털화시킴으로서 정확성과 함께 원자로의 안정성을 향상시킨 특색있는 계통이다. 따라서 영광 3,4호기 시뮬레이터에서는 CPC/COLSS 계통에 대한 정확한 모델링을 하여 시험을 통해 성능및 기능에 대한 검증을 마침으로서 CPC/COLSS 시뮬레이션 모델 개발이 성공적으로 되었고 영광 3,4호기 운전 특성에 맞는 시뮬레이터를 개발하였다.

  • PDF

A Framework on secure remote control in plant system (안전한 공장 원격제어 시스템 프레임 워크)

  • Lee, Jaemin;Mun, Jiman;Jung, Souhwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.989-992
    • /
    • 2012
  • 본 논문에서는 안전한 공장 원격제어를 위한 시스템 프레임 워크를 제안한다. 공장기계와 IT의 융합으로 기술 발전함에 따라 공장 제어 시스템을 공장내부에서는 무선 제어시스템, 공장 외부에서는 원격 시스템의 필요성이 대두되어 많은 연구들이 진행되고 있다. 기존의 공장 자동화 시스템 SCADA(Supervisory Control And Data Acquisition)는 생산 공정 및 플랜트의 상태를 감시하고 제어하기 위한 목적으로 개발되었지만 원격제어 관련 내용이 부족하다. 공장 내부 보안을 위한 표준으로 ISA99 Security Standards에서도 통합 공정 제어 Zone & Conduits 방식 제시 공장의 각 영역을 Zone으로 나누고 허가된 사용자만 Conduit를 통해 다른 Zone의 노드와 통신을 하는 방식을 제안하였다. 하지만, 전체적인 프레임워크는 정의를 하고 있으나 외부 원격 제어 내용 부족하다. 따라서 본 논문에서는 스마트폰을 활용한 공장 외부에서의 안전한 원격 제어를 제공하는 통합관제시스템 프레임워크 구조를 제시하여 향후 관련 기술에 대한 기준점을 제시한다.

A Study on the Effectiveness of the Audit Review System (감리제도의 실효성에 대한 연구 - 회계정보의 질을 중심으로 -)

  • Kwak, Young-Min;Jung, Jae-Jin
    • Management & Information Systems Review
    • /
    • v.33 no.5
    • /
    • pp.71-84
    • /
    • 2014
  • We examine evidence on the relationship between firms that targeted by the Financial Supervisory Service for allegedly manipulating annual earnings and accounting quality measured by the discretionary accruals, an issue with important public policy implications. The main purpose of this paper is to empirically investigate the extent to which Korean WDS(Window Dressing Settlement) firms identified by the financial supervisory service in their audit review exhibit higher level of accounting quality in order to avoid any potential negative effects and to regain public confidence after audit review. In this study, we analyzed 51 WDS firms and 102 control firms which traded in the Korean Stock Exchange market during the period from 2000 to the 2010. The number of observations subject to various tests are 251 and 502 firm-years for WDS and control samples respectively across the 5 year sample period. The results of the study show that the accounting quality after auditor review be significantly improved. This result suggests that the FSS's audit review system would control the accounting quality and then improve the transparency of the accounting information. Thus it may be suggested that the current audit review system is efficient ways to lead listed firms to provide transparent financial statements.

  • PDF

Development of Platform for Connection of Electronic Power Backbone based on D-TRS (D-TRS 기반 전력기간망 접속을 위한 게이트웨이 플랫폼 개발)

  • Song, Byeong-Kwon;Lee, Sang-Hun;Jeong, Tae-Eui;Kim, Gun-Woong;Kim, Jin-Chul;Kim, Young-Eok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.382-384
    • /
    • 2008
  • D-TRS is a method of wireless communication. This method will be able to use several frequency for multiple user used chanel together. TETRA of D-TRS technology is not rented network. Using TETRA network has the strong point which cost better than CDMA network of rental network. Master server of SCADA(Supervisory Control And Data Acquisition) system is realtime supervise control and a data acquire the control system or the RTU(Remote Terminal Unit). The present paper is developed and proposal the gateway platform for electronic power backbone network based on D-TRS. This gateway platform is converted DNP3.0 messages with TETRA PDU and converted TETRA PDU with DNP3.0 messages. Master server and FRTU will be able to send and receive DNP3.0 message via TETRA network using this gateway platform.

  • PDF

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

Implementation and application of remote control system using LACC(Local Area Control Center) (LACC를 이용한 원격제어 시스템 구현 및 적용)

  • Park Tae-Jin;Jang Myung-Kee;Chung Seung-Ryul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.15-22
    • /
    • 2006
  • Nowadays, there is called energy saving, that it is accomplished with a lot study and application development as according to demand of all around world. It is using to network device of wire or wireless such as internet, lan, plc, and zigbee and that we should be accomplished to study about method that spending a little cost to fatal error in control system that be expected of frequent occurrence on network, and that have method to do construction a little bit tried out. Also, in that such a embedded system with network function case, there is important thing that it is remote management to network node and control methods to trust because firmware upgrade have the advantage of more than the other device. In this paper, we have verified through a result of experiment for efficient remote management and control method as previously stated in this paper, that it is area of the PLC for sensor node and doing management to relay, and implementation of the LACC which is core part of the ESS, and in order to get a result to trust from doing analysis of capacity and test.