• Title/Summary/Keyword: supervisory control

Search Result 351, Processing Time 0.033 seconds

Design and Operation of DC Home Grid with PV-Battery-Ultracapacitor (태양광-배터리-수퍼캡을 갖는 직류 홈 그리드의 설계 및 운영)

  • Heryanto, Nur A.;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • In this study, the design and operating strategy of DC home grid with PV, battery, and ultracapacitor have been discussed, The proposed sizing method can find the optimum size of the battery and PV which can reduce yearly utility energy consumption, whereas the control scheme can maintain the DC-bus voltage level of the DC home grid under different operating conditions, where day or night time operation, load and PV power levels, and the maximum current and state-of-charge of batter are considered. In addition, a supervisory power management strategy has been suggested, and its validity has been verified by HILS (hardware in-the-loop simulation) results.

Calculation of Network Analysis and Fault Decision using Equality Constraint Condition with MATLAB (등호제약조건을 이용한 계통 해석 및 고장판단 계산 구현)

  • Yang, Min-Uk;Kim, Kern-Joong;Hwang, In-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2101-2106
    • /
    • 2009
  • The power system state estimation and prediction are very important for operation. Because that accidents of the Power system are the cause that many devices and etc are damaged. Currently, almost every power systems have 2nd,3rd back-upsystem for prevention of accident. But prevention of accident by miss-operation, due to operator or miss data, has not acounter plan. Because, we need to estimate the power system for correcting miss data and preventing miss operation by operator. We suggest algorithm for integrity of power system network data.

A Study of SCADA Function Specific Design in Korean EMS (한국형 EMS의 SCADA Function 세부설계에 관한 연구)

  • Lee, Hyo-Sang;Kim, Wan-Hong;Park, Min-Ryung;Yoon,, Yeo-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.402-403
    • /
    • 2007
  • 전력계통의 효율적인 제어와 운용을 위해서는 전력계통을 구성하는 각종설비의 모델링뿐만 아니라 실시간 시스템 운용 상태에 대한 정확하고 신뢰할 수 있는 정보가 필요하다. 이러한 목적을 위해 현대의 전력계통은 광범위한 데이터를 취득하는 SCADA(Supervisory Control And Data Aquisition)시스템을 기본적으로 갖추고 있다. 본 논문에서는 한국형 에너지관리시스템(Korean Energy Management System)에서의 데이터 취득, 처리, 제공, 제어 등의 기능을 수행하는 SCADA의 요구사항과 설계내용에 관해 소개한다.

  • PDF

EMS 메모리 데이터베이스 동기화 기능 개선 개발

  • Kim, Tae-Seop;Kwak, Jong-Kab;Lee, Seok-Chan
    • Annual Conference of KIPS
    • /
    • 2015.10a
    • /
    • pp.1131-1133
    • /
    • 2015
  • EMS(Energy Management System)는 우리나라 전체 전력 계통을 실시간으로 감시, 제어하고 계통 주파수를 자동으로 조정하여 성능 최적화를 유도하는 시스템으로 전력 계통의 두뇌와 같은 역할을 한다. 본 연구에서는 차세대 EMS(Next Generation Energy Management System: NG-EMS)에서 Enable과 Standby 서버 간 데이터베이스 동기화 기능 개선 개발 기술을 소개한다. EMS는 원방제어감시에 사용되는 SCADA(Supervisory Control And Data Acquisition) 데이터를 포함하여 자동발전, 경제급전 등의 전력 계통을 위해 가공된 데이터를 메모리 데이터베이스에 저장한다. 본 연구에서는 EMS의 메모리 데이터베이스에 저장되어 있는 데이터를 시스템 운영자가 선별을 하여 동기화를 수행할 수 있도록 한다. 또한 동기화 되고 있는 현황을 가시적으로 보임으로써 Enable 서버의 장애 발생 시 Standby 서버로의 대체가 유연하고 안정적이며, 신뢰성을 줄 수 있다.

Stream cipher communication protocol based on Irrational numbers in SCADA System (SCADA 시스템에서 무리수 기반의 스트림 암호화 통신 프로토콜 연구)

  • Kim, Seong-Jong;Kim, Hyung-Joo;Kim, Hyung-Min;Jun, Moon-Seog
    • Annual Conference of KIPS
    • /
    • 2012.11a
    • /
    • pp.990-993
    • /
    • 2012
  • SCADA(Supervisory Control and Data Acquisition) 시스템은 국가중요기반망인 전력, 가스 등을 제어하기 위해 사용되어 왔다. 최근에는 기존의 폐쇄적인 통신 환경과 달리 외부망과 연결된 개방 통신 환경을 사용함에 따라 안전한 통신을 위한 암호화 기술이 연구되고 있다. 기존 시스템에 적용되고 있는 프로토콜들은 공유키를 갱신하기 위해 수동적으로 설정해야했다. 본 논문에서는 SCADA 시스템을 구성하는 Server와 RTU가 상호 인증하여 무리수 기반의 스트림 암호화 통신과 타임스탬프를 이용한 키 갱신 프로토콜을 제시하여 재사용공격과 가장공격이 불가능한 실시간 암호화통신 프로토콜을 연구하였다.

Information and Communication Technologies for Smart Water Grid Applications

  • Ballhysa, Nobel;Choi, Gyewoon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.218-226
    • /
    • 2019
  • The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.

Antecedents of Disclosure on Internal Control and Earnings Management

  • ZULFIKAR, Rudi;MILLATINA, Firda;MUKHTAR, Mukhtar;ASTUTI, Kurniasih Dwi;ISMAIL, Tubagus;MEUTIA, Meutia;FAZRI, Edward
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.391-397
    • /
    • 2021
  • This study examines the effect of independent commissioners and the Audit Committee on internal control disclosure and its implications for earnings management in the banking industry listed on the Indonesia Stock Exchange for the period 2016-2018. In this study, a purposive sampling technique was used, combined with two multiple regression analysis models. The final sample for this study comprised 30 companies over the three years of observation, such that there were 90 observations in total. This study indicates that independent commissioners, as measured by their composition, do not affect the disclosure of internal control. However, as measured by the number of members, the Audit Committee had a positive effect on internal control disclosures. This study also indicates that the disclosure of internal control as measured by the Internal Control Disclosure index affects reducing the negative practice of earnings management. This study proves that the Audit Committee's role is very dominant in assisting the Board of Commissioners in supervising internal control. This has implications for reducing earnings management practices. However, the Independent Commissioner's role in the Indonesian banking industry has not been optimal in carrying out the supervisory function in this study.

Implementation and application of remote control system using LACC(Local Area Control Center) (LACC를 이용한 원격제어 시스템 구현 및 적용)

  • Park Tae-Jin;Jang Myung-Kee;Chung Seung-Ryul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.15-22
    • /
    • 2006
  • Nowadays, there is called energy saving, that it is accomplished with a lot study and application development as according to demand of all around world. It is using to network device of wire or wireless such as internet, lan, plc, and zigbee and that we should be accomplished to study about method that spending a little cost to fatal error in control system that be expected of frequent occurrence on network, and that have method to do construction a little bit tried out. Also, in that such a embedded system with network function case, there is important thing that it is remote management to network node and control methods to trust because firmware upgrade have the advantage of more than the other device. In this paper, we have verified through a result of experiment for efficient remote management and control method as previously stated in this paper, that it is area of the PLC for sensor node and doing management to relay, and implementation of the LACC which is core part of the ESS, and in order to get a result to trust from doing analysis of capacity and test.

Recent development of high gradient superconducting magnetic separator for kaolin in china

  • Zhu, Zian;Wang, Meifen;Ning, Feipeng;Yang, Huan;Li, Peiyong;Zhang, Yiting;Wang, Zhaolian;Zhang, Guoqing;Hou, Zhilong;Liu, Zhongxiu;Dai, Zhong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.5-8
    • /
    • 2017
  • A series of high gradient superconducting magnetic separator (HGMS) for kaolin has been developed. It is used for processing kaolin to increase the brightness or whiteness whether it is for paper or ceramic applications. The HGMS system mainly consists of a solenoid magnet with a zero boil-off helium cryostat, a double reciprocating canisters system, and a PLC (Process Logic Controller) fully automatic control system based on SCADA (Supervisory Control and Data Acquisition) system. We have successfully developed CGC-5.5/300 and CGC-5.0/500 HGMS systems in the recent years, and now three sets of them are on-site operation in different customers. This paper will present recent progress of the HGMS system, the results of some experiments on processing kaolin clay used HGMS, and the on-site operation.

An Analysis of Supervisory Control Performance under Urgent Enviornments (감시제어작업에서 긴급상황의 수행도 분석)

  • 오영진;이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.32
    • /
    • pp.243-253
    • /
    • 1994
  • Work environments have been changed with the advent of new technologies, such as computer technology. The newer technologies, the more changes in our work conditions. However, human cognitive limits can't keep up with the change of work environments. Mental workload has been an important factors in designing modem work environments such as human-computer interaction. Designing man-machine systems requires knowledge and evaluation of the human cognitive processes which control information flow workload. Futhermore, under an urgent situation, human operator may suffer the work stress, work error, and resultant deleterious work performance. To describe the work performance in the urgent work situations, with time stress and dynamic event occurence, a new concept of information density was introduced. For a series of experiments performed for this study, three independent variables(information amount system processing time, information density) were evaluated using such dependent variables as reaction time, number of error, and number of failure. The results of statistical anlysiss indicate that the amount of information effected on all of five dependent measure. Number of failure and number of secondary task score were effected by both amount of information and operational speed of system, but reaction time of secondary task were effected by both amount of information and information density.

  • PDF