• Title/Summary/Keyword: superimposed strength

Search Result 20, Processing Time 0.017 seconds

Prediction Model for Relaxation of Welding Residual Stress under Fatigue Loads (피로하중하 용접잔류응력 이완 추정모델)

  • 한승호;신병천
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.84-90
    • /
    • 2002
  • The strength and the life of welded components are affected extensively by the residual stresses distributed around their weldments not only under static loads, but also fatigue loads. The residual stress can be superimposed with externally applied loads, so that unexpected deformations and failures of members will be occurred. These residual stresses are not kept constant, but relaxed or redistributed during in service. Under static loads the relaxation takes place when the external stress superimposed with the residual stress exceeds locally the yield stress of material used. It is shown that under fatigue loads the residual stress is considerably relieved by the first or flew cycle loading, and then gradually relaxed with increasing loading cycles. In this study the phenomenon and mechanism of the stress relaxation by mechanical means were investigated and a model to predict quantitatively the residual stress relaxation for the case of static and fatigue loading condition was proposed.

The Analysis on the Clothing Construction Factors and the Sewability of the Mechanical Industry Working Clothes - With Reference to the Seam Strength and Seam Elongation According to the Material and Seam Types - (기계 산업용 작업복 의복구성요인과 봉제성능 분석 - 소재 및 솔기별 봉합강도와 봉합신도 중심으로 -)

  • Park, Gin-Ah
    • Journal of Fashion Business
    • /
    • v.14 no.2
    • /
    • pp.57-72
    • /
    • 2010
  • The purposes of the research were to find out the clothing construction factors of the mechanical industry working clothes by analyzing the working clothes supplied to 5 subject companies; and to suggest the optimized sewing conditions and the seam strength and elongation experimental data according to the clothing material and seam types implied to the working clothes collected. The fabric types and trimmings used for the mechanical manufacturing working clothes were Polyester/Cotton(65/35%), Polyester/Rayon(65/35%), Cotton(100%); and linings, interlining, various fastenings etc. 2 stitch types, i.e. lock and two-thread chain stitches were applied to the construction of the flat, lap felled, French, superimposed, lapped and bound seams for the seam strength and elongation experiment. The results derived from the experiment were as follows. (1) The seam strength results according to the seam types were high in the order of lap felled>lapped>flat, superimposed and French seams. (2) Considering the features of the seam construction, as the number of fabric layers at the seam line increased the seam strength also increased. (3) Apart from the highest seam strength from the experiment using the net lining with the main fabric, the seam construction consisting of two fabric layers with the interlining showed relatively high seam strength results. (4) The seam elongations according to the stitch types were high in the order of two-thread chain>lock stitches.

Effect of Electrical Muscle Stimulation Training With and Without Superimposed Voluntary Contraction on Rectus Femoris and Vastus Intermedius Thickness and Knee Extension Strength

  • Weon, Young-soo;Kim, Jun-hee;Gwak, Gyeong-tae;Lee, Do-eun;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.140-146
    • /
    • 2022
  • Background: The superimposed technique (ST) involves the application of electrical muscle stimulation (EMS) during voluntary muscle action. The physiological effects attributed to each stimulus may be accumulated by the ST. Although various EMS devices for the quadriceps muscle are being marketed to the general public, there is still a lack of research on whether ST training can provide significant advantages for improving quadriceps muscle strength or thickness compared with EMS alone. Objective: To compare the effects of eight weeks of ST and EMS on the thicknesses of the rectus femoris (RF) and vastus intermedius (VI) muscles and knee extension strength. Methods: Thirty healthy subjects were recruited and randomly assigned to either the ST or EMS groups. The participants underwent ST or EMS training for eight weeks. In all participants, the thicknesses of the RF and VI muscles were measured before and after the 8-week intervention by ultrasonography, and quadriceps muscle strength was measured using the Smart KEMA tension sensor (KOREATECH Co., Ltd.). Results: There were significant differences in the pre- and post-intervention thicknesses of the RF and VI muscles as well as the quadriceps muscle strength in both groups (p < 0.05). RF thickness was significantly greater in the ST group (F = 4.294, p = 0.048), but there was no significant difference in VI thickness (F = 0.234, p = 0.632) or knee extension strength (F = 0.775, p = 0.386). Conclusion: EMS can be used to improve quadriceps muscle strength and RF and VI muscle thickness, and ST can be used to improve RF thickness in the context of athletic training and fitness.

An Experimental Study on the Concrete Filled Circular Steel Columns with D/t (지름두께비를 고려한 콘크리트충전 원형강관기둥에 관한 실험적 연구)

  • 한병찬;임경택;엄철환;연길환;윤석천;정수영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.215-218
    • /
    • 1995
  • This paper presents an experimental study on the strength and deformation of concrete-filled circular steel short columns. Six specimens of concrete-filled circular short columns were tested under concentric compressive load. For comparsion, three specimens of circular steel short columns were also loaded to failure. The ultimate strength, ductility, and confinement mechanism of columns were compared. In the comparison, the effect of witch-thickness ratio and concrete compressive strength on the behavior of colimns were examed. As a result, the axial load verse axial average strain relationship of concrete-filled circular steel columns was very stable, because of interactions between the concrete and steel, the strength are 13% and 30% larger than the strength extimated by simply superimposed method of the concrete and steel. The ratio of the circumferential to longitudinal strain increment, both measured on the steel suface, was 0.28 up to the longitudinal strain of 0.1%, increases from 0.3 to 0.8 between the strain of 0.1% to 0.3%, and 0.8 beyond the strain of 0.3%

  • PDF

Relaxation of Welding Residual Stresses under Fatigue Loads (피로하중하 용접 잔류응력 완화의 정량적 평가)

  • Han, S.H.;Kang, S.B.;Shin, B.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.424-429
    • /
    • 2001
  • Residual stresses can be produced during manufacturing processes, eg. welding, machining and plastic working, and also in service. It can be superimposed with externally applied loads, so that unexpected deformations and failures of members will be occurred. Especially, the strength and the life of welded components are affected extensively by the residual stresses distributed around their weldments not only under static loads, but also fatigue loads. These residual stresses are not kept constant, but relaxed or redistributed during service. Under static loads the relaxation takes place when the residual stress superimposed with external stress exceeds locally the yield stress of material used. It is shown that under fatigue loads the residual stress is considerably relieved by the first or few cycle loading, and then gradually relaxed with increasing loading cycles. Although many investigations in this field have been carried out, the phenomenon and mechanism of the stress relaxation by mechanical means are still not clear, and there are few comprehensive models for predicting specific effects on the stress relaxation. In this study, the effects of applied static and fatigue loads on the residual stress relaxation were Investigated, and a model to predict quantitatively the residual stress relaxation was proposed.

  • PDF

Numerical Analysis for Optimum Reinforcement Length Ratio of Reinforced Earth Retaining Wall (보강토옹벽의 최적 보강길이비 산정을 위한 수치해석적 연구)

  • Park, Choonsik;Ahn, Woojong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.5-14
    • /
    • 2018
  • Recently, method of reinforced earth retaining wall have been proposed according to the material of facing, geosynthetic, construction method, and facing slope. However, the regulations such as the design method and detailed review items according to each construction method are not clear, and collapse due to heavy rainfall frequently occurs. In this study, to obtain a more stable technical approach in the design of reinforced earth retaining wall, the combination of the pullout failure of reinforced earth retaining wall and the optimal reinforcement ratio of height using reinforced earth retaining wall using a single strength reinforcement is assumed, optimum design of stiffener, optimal design of superimposed wall and optimum length ratio of reinforcement material of geosynthetics are proposed through safety factor according to reinforcement length ratio (L/H).

Effect of residual stress and geometric imperfection on the strength of steel box girders

  • Jo, Eun-Ji;Vu, Quang-Viet;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • v.34 no.3
    • /
    • pp.423-440
    • /
    • 2020
  • In the recent years, steel box girder bridges have been extensively used due to high bending stiffness, torsional rigidity, and rapid construction. Therefore, researches related to this girder bridge have been widely conducted. This paper investigates the effect of residual stresses and geometric imperfections on the load-carrying capacity of steel box girder bridges spanning 30 m and 50 m. A three - dimensional finite element model of the steel box girder with a closed section was developed and analyzed using ABAQUS software. Nonlinear inelastic analysis was used to capture the actual response of the girder bridge accurately. Based on the results of analyses, the superimposed mode of webs and flanges was recommended for considering the influence of initial geometric imperfections of the steel box model. In addition, 4% and 16% strength reduction rates on the load - carrying capacity of the perfect structural system were respectively recommended for the girders with compact and non-compact sections, whose designs satisfy the requirements specified in AASHTO LRFD standard. As a consequence, the research results would help designers eliminate the complexity in modeling residual stresses and geometric imperfections when designing the steel box girder bridge.

Strength Characteristics of Anlsotropic Overconsalidated Clay (이방성과압밀점토의 강도특성)

  • 홍원표
    • Geotechnical Engineering
    • /
    • v.4 no.3
    • /
    • pp.35-42
    • /
    • 1988
  • A series of consolidated-undrained cubical triaxial tests was performed to investigate the three- dimensional strength characteristics of anisotropic overconsolidated clay. All specimens sampled in field were loaded under conditions of principal stress directions fixed and aligned with the directions during sampling. A sufficient number of tests It was performed to deter.mine the three- dimensional failure surface in the octahedral plane. The adjusted effective friction angles obtained by the stress state projected on the same octahedral plane did not show anisotropy, while the measured effective friction angles showed considerally difference according to the axes of speccimens. Therefore, Lade failure criterion proposed fort isotropic materials could be also used practically for anisotropic overconsolidated clay. The direction of the plastic strain increment wrectors superimposed on the principal stress space was nearly perpendicular to the traces of the failure surface in the octahedral plane.

  • PDF

Evaluation on Shear Behavior of Double-tee Dap-ends with the Least Depth from Optimization Proces (최적이론에 의하여 설계된 최소 깊이 더블티 댑단부 전단거동 평가)

  • 유승룡;김대훈
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.43-54
    • /
    • 1999
  • Shear tests are performed on four full-scale 12.5 m proto-type models, "least depth double tee," which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product. Korean building code requirements, construction environments and economy are considered as the main factors to establish the process. All of the specimens tested fully comply with the shear strength requirements as specified by ACI 318-95. The research has shown following results. 1) The development length requirement of ACI 318-95 does not seem a good predictor for the estimation of bond failure in a beam with the strands below the supports. 2) The load required for the first initial coner cracking in the dap end and first web shear cracking does not seem to have any relation with the dimension and shear strength of the section in the test beams. 3) The strand slip has a direct relationship with the web shear cracking. However, the coner cracking in the dap end does not give any help for the slip in anchorage. 4) Use of whole area for bearing steel at the bottom of dap end is desired for safe bearing pressure design in the precast prestressed double tee beams. 5) The deflection of beam influences directly on the amount of strand slip at the anchorage after initiation of it, and relationship between them are very linear.

Evaluation on Flexural Behavior of Double-tee Slabs with the Least Depth from Optimization Process (최적이론에 의하여 설계된 최소 깊이 더블티 슬래브의 휨거동 평가)

  • 유승룡;김대훈;유재천
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.141-152
    • /
    • 1999
  • Precast prestressed double-tee slab may be designed by the PCI Design Handbook. It is based on the bridge construction and is required for reorganization for the use of buildings in the domestic construction environments. Much enhanced sections are developed from the reforming process on the determined design factors in the previous experimental works on double tees. Pre-determined shape, reinforcement detail, and 5000 psi concrete strength can not be expected as the best solution for the domestic construction requirements because large amount of use on that systems are anticipated. Flexural tests are performed on four full-scale 12.5m proto-type models, "least depth double tee", which are resulted from the optimization process. Domestic superimposed live load regulation, domestic material properties which is available to product, building design requirements and economy in construction are considered as the main factors to establish. the first two sections are double tee section for 1.2 ton/$\m^2$ market live load with straight and one-point depressed strands and the second two are for 0.6 ton/$\m^2$ parking live load with those strand types. All of the specimens tested fully comply with the flexural strength requirements as specified by ACI 318-95. However, the research has shown that following improved considerations are needed for better result in practice. The locations and method of connection for the lowest bottom mild bar, connection method between precast and cast-in-place concrete, and dap-end reinforcement are need to be improved.