Estimation of the critical current of CORC® conductor using the measured magnetization losses

  • Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Woo-Seok, Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.46-49
    • /
    • 2022
  • Since CORC®(Conductor on Round Core) is made of multiple strands of a superconducting tape to conduct a large current, it is difficult to measure the critical current due to the limitation of a capacity of a power supply. The magnetization loss of a superconductor is dependent on the full penetration field. The full penetration field corresponds to the inflection point of the magnetization loss graph with respect to the external magnetic field. We propose a method to predict the critical current of CORC® indirectly. This method uses the measured magnetization losses of various CORC® samples for the prediction of the critical currents.

초전도 HGMS법에 의한 제철공정 폐수처리 (Treatment of steelmaking process waste water by superconductor HGMS method)

  • 김태형;하동우;오상수;하홍수;박성국;이상길;노유미
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.41-44
    • /
    • 2006
  • This study introduced waste water treatment method by superconducting HGMS(High Gradient Magnetic Separation). HGMS treatment method is high efficient method for various waste water, we have surveyed superconducting magnetic separation technology. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel mesh, which is a core component in the magnetic separation system. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the wasted water obtained from steelmaking process of POSCO can be separated with high efficiency.

Characteristics comparison between air-cored and iron-cored 100 kW HTS field winding synchronous motors

  • Yoon, Jonghoon;Bong, Uijong;An, Soobin;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권2호
    • /
    • pp.38-43
    • /
    • 2020
  • This paper presents comparative research on characteristics of air-cored and iron-cored high-temperature superconductor (HTS) field winding synchronous motors. The 100 kW air-cored model is designed analytically by Spatial Harmonic Method, and based on this model, the iron-cored model having the same output power is designed for comparison. Due to the substantial difference of permeability property between air and iron-core, there is a difference of magnetic field magnitude and angle with respect to the HTS tape c-axis, resulting in a different critical current of the field winding considering the anisotropic property of HTS tape. For a detailed comparison between two models, the following key motor characteristics are calculated through the Finite Element Method (FEM) simulation: 1) critical current; 2) HTS wire length; and 3) torque characteristics. From the simulation results, it can be confirmed that the critical current value of the iron-cored model increases by 33 %. Also, in the case of the superconducting wire consumption, those of the iron-cored and air-cored models are 95.3 m and 815.6 m, respectively. So the wire usage can be reduced to about 88 % by using iron core. However, in terms of torque characteristics, the torque ripple of the iron-cored model is about twice as large as that of the air-cored model, which may be a disadvantage on vibration and acoustic noise.

직렬 연결된 두 코일과 YBCO Coated Conductor로 구성된 초전도 전류제한기의 권선방향과 권선 비에 따른 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of the SFCL with Magnetically Coupled Two Coils and YBCO Coated Conductor Due to the Winding Direction and the Turn Number' Ratio Between Two Coils)

  • 이동혁;두호익;김용진;한병성;한상철;이정필
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.52-56
    • /
    • 2011
  • The ongoing Superconducting Fault Current Limiter(SFCL) development mainly has focused on the application of commercializaton and power system through combining with normal-conducting device, moving away from current-limiting method, which is solely dependant on the existing superconductor. Compared to the structural development above, on the other hand, the research on applying superconducting current-limiting element to SFCL, the heart of SFCL, still has a lot left to do, apart form traditional resistive type SFCL. In this study, we looked into the current limiting characteristic of SFCL using core and coil. YBCO coated conductor with stainless steel stabilizer layer was verified by the excellent of current-limiting element of the resistive type SFCL that has a high Jc and index as well as being superior in mechanical property. Also, we study temperature characteristics and resistance characteristics, max voltage, response time and current-limiting ability that can be an indicator as current-limiting element while applying to superconducting current-limiting element caused by variation of winding direction, winding ratio of SFCL using core and coil.

61심 BSCCO 2223 고온초전도 선재의 접합부 제조 (Fabrication of Superconducting Joints between 61 Filaments of BSCCO 2223 Tapes)

  • 김철진;박성창;유재무
    • 한국세라믹학회지
    • /
    • 제35권2호
    • /
    • pp.137-144
    • /
    • 1998
  • 고온초전도체 61심 Bi-2223 선재간의 초전도 접합부위를 화학적 부식 및 열적· 기계적 반복 공정에 의하여 제조하였다. 초전도 선재 테이프의 은 피복재 한쪽 표면을 초전도체와 반응하지 않는 부식액(NH4OH:H2O2=1:1)으로 화학적으로 제거한 다음, 두 시편을 일출가압 성형하여 접합시편을 제조하였고 일련의 서로 다른 열적· 기계적 처리를 거쳐 접합부의 물성 및 미세구조를 분석하였다. 접합부를 따라 임계전류(Ic) 변화와 전류전압 곡선의 특성을 측정하기 위하여 여러 단자를 접합부 주위에 설치하여 부위별 I~V 특성을 측정한 결과 단심선재에 비하여 다심선재에서 선재 전체의 통전 능력을 좌우하는 천이구간의 임계전류값이 높았다. 그러나 단심에 비해 다심선재는 천이급속도를 나타내는 n값이 다심선재내 각각의 초전도 core들의 상호작용에 의하여 낮은 값을 나타내었다. 접합부의 임계전류 통전성은 반복적인 가압성형 공정과 서냉반응 열처리 공정에 의하여 향상되었다.

  • PDF

BSCCO 고온초전도 선재의 접합특성 연구 (A Study of Joint Characteristic of BSCCO Superconductor Tape)

  • 김정호;김중석;김태우;지봉기;주진호;나완수
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.378-382
    • /
    • 1999
  • We evaluated the effect of joining process such as contact method, shape of joined area and pressure on the electrical property of Bi-2223 superconducting tape. It was observed that the current capacity was reduced at the transition area of the joined tape and was significantly dependent on the uniaxial pressure. The lap-joined tape, fabricated with a pressure of 1,000-1,600 MPa, show the highest value of current capacity(80-90%) of the tape itself. It is believed the highest value of current capacity results from improvement in core density, contacting area and grain alignment, etc. In addition, the irreversible strain( ${\varepsilon}$ irrev) for the joined tape· was measured to be 0.1%, smaller than that of enjoined tape( ${\varepsilon}$ irrev = 0.3%). The decrease in the strength and irreversible strain for joined tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

BSCCO(2223) 초전도 선재의 접합공정 연구 (A Study of Joining Method of BSCCO(2223) Tape)

  • 김정호;김중석;김태우;지붕기;주진호;나완수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.1-7
    • /
    • 1999
  • we evaluated the effects of joining process such as contact method. shape of joined area and pressure on the electrical and mechanical properties of Bi-2223 superconducting tape, Specifically. the current capacity of the jointed tape was measured as a function of uniaxial pressure. and the thermal shock, bonding strength and the thermal of the tape were evaluated and correlated to the microstructural evolution. It was observed that the current capacity was significanrly dependent on the uniaxial pressure The jointed tape, fabricated with a pressure of 1,000-1,600 Mpa. showed the highest value of current capacity results from improvements in core density, contacting area and grain alignment, ect. In addition, the strength of jointed tape was measured to be 86 Mpa, which is about 88% of the unjoined ape's strength. The irreversible strain($\varepsilon$irrev) for the jointed tape was measured to be 0.1%, smaller than that of unjoined tape ($\varepsilon$irrev= 0.3%). The decrease in the strength and irreversible strain for jointed tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.

회전실험에서의 다결성 $Y_1Ba_2Cu_3O_{7-\delta}$ 초전도체내의 vorterx flux의 거동 (Behavior of the Vortex Flux in a Polycrystalline $Y_1Ba_2Cu_3O_{7-\delta}$Superconductor in a Rotational Experiment)

  • 박성재;김용석;김채옥
    • 한국전기전자재료학회논문지
    • /
    • 제11권9호
    • /
    • pp.752-757
    • /
    • 1998
  • Rotational Magnetization-vector measurements have been performed on a polycrystalline $Y_1Ba_2Cu_3O_{7-\delta}$ sample in field-cooled condition at 4.2 K. The experimental results show that vortex flux density(B) consists of 3 groups :(1) a weak pinning part ($B_w$) which stays at a fixed angle relative to the magnetic field f(H) ; (2) a strong pining part($B_s$) which rotates rigidly with the sample and has same magnitude with the sample rotation, and(3) and intermediated pining part ($B_i$) which rotates rigidly with the sample, but whose magnitude changes with the sample rotation Our results have been explained in terms of a distribution in the strength of the vortex pinning torque and a repulsive intervortex torque.

  • PDF