Effect of Hardening Accelerators on the Adiabatic Temperature property Properties of Precast Concrete and FEM analysis for Evaluating the Crack Performance (경화촉진제를 사용한 프리캐스트 콘크리트의 단열온도특성 및 FEM해석에 의한 균열성능 평가에 관한 연구)

  • Min, Tae-Beom;Cho, In-Sung;Mun, Young-Bum;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, initial crack index was evaluated by FEM analysis to find the crack propagation from hydration heat in precast concrete. As results, as the usage of hardening accelerator increased, initial compressive strength increased and setting time was shortened. Additionally, as amounts of hardening accelerators increased, the central temperature of concrete increased and the time to reach the highest temperature was shortened. It was demonstrated that the hardening accelerators accelerated the hydration reaction of cement, and caused the increase of hydration heat within the short period of time. Furthermore, the crack index for evaluating the heat level was performed by FEM. As results, there was no problem about the cracks, despite of the growth of initial high hydration heat. This is because of the increased tensile strength that is large enough to sustain the thermally induced-stress.

Study on Bearing Capacity of Ultra High Strengh End Extended PHC Pile by Loading Test (재하시험을 통한 초고강도 선단확장 PHC말뚝의 적용성 연구)

  • Hwang, Ui-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.269-275
    • /
    • 2019
  • As the national industry is developing gradually due to the expansion of the economic scale, the construction of large and super high-rise structures for building social infrastructure has been increasing, and studies have been conducted actively to transmit the large loads at the upper portion to the lower bedrock. In this study, the PHC was extended to an ultra-high strength PHC, which increased the concrete compressive strength of the PHC from the conventional 80 MPa to 110 MPa, and the PHC, which extended the tip of the pile. After construction with the driving method and injected pile method, the tendency of the bearing capacity was tested through a load test. Measurements of the bearing capacity of the extended PHC using the pile driving method revealed the main surface friction force to be smaller than that of the general PHC, and the stet-up effect was also insignificant. On the other hand, the effect of the friction force on the ground surface when the injected pile method was applied is expected to increase the bearing capacity when the gap between the main surface and the ground is wide and the cement paste is filled tightly. In addition, the ultrahigh strength PHC showed higher bearing capacity than the conventional PHC, and the permissible pile stress was less than 60%. Therefore, it is possible to reduce the number of piles and reduce the construction cost and effect of shortening the length of the pile by designing the tip of the pile on the ground with the intensity of soft rock as a method for utilizing the increased strength of the ultra-high strength PHC.

Development and Effectiveness of Private Parking Information Algorithm (복합용도 초고층빌딩에 대한 개별주차정보제공 알고리즘 개발)

  • Kim, Young-Sun;Nam, Baek;Lee, Choul-Ki;OH, Young-Tae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.13-21
    • /
    • 2013
  • Super high-rise buildings of combined use such as large shopping malls and multiplex etc. have larger parking facilities than general buildings and are characteristic of an increase in the number of the entrance and the exit connecting internal external space of the parking lot. These features cause a congestion of internal traffic by increasing car driving distance in the parking lot, and vehicle idling increases by drivers wander the parking lot in order to find parking space. In addition, they make drivers suffer from lots of difficulties due to parking including increasing their walking line after parking. Therefore, in this study, we developed individual parking information provision algorithm to specify the optimal parking place for drivers according to the purpose of visiting a building and the drivers' moving path, and selected new construction site for the second lotte world in order to evaluate the algorithm developed and performed evaluation. As a result of the evaluation, it was analyzed that in the case of applying the individual parking information provision algorithm compared to the existing parking information provision algorithm, moving distance in the parking lot decreases around 7.43~83.4%, and that in the case of $CO_2$ emission, it decreased about 47.7% on average, which indicates that the efficiency resulted from application of the individual parking information provision algorithm is very high as the application effects are tested.