• 제목/요약/키워드: summer design temperature

검색결과 150건 처리시간 0.027초

하복의 온열생리학적 기초연구 (The Basic Studies of Thermal Physiology for Summer Wears)

  • 성수광;정현옥
    • 한국의류학회지
    • /
    • 제9권2호
    • /
    • pp.57-65
    • /
    • 1985
  • In the experiment with a basic material for the design of summer wear that comfort can be obtained in temperature, to get individual differences, clothing styles (slacks, skirt), material differences(T/C, cotton), and the contrast between when naked and dressed, when two healthy females were dressed four kinds of summer wear as an object of experiment under the regular warm temperature environmental condition (24, 28, 32, $36^{\circ}C$, $60\pm10\%$ RH), the measurement of physiological, phychological change was taken and the result goes as follow; 1. Mean skin temperature rose by clothing, body weight loss decreased below $32^{\circ}C$, thermal sensation changed toward low temperature by $2\~3^{\circ}C$. 2. Mean skin temperature, body weight loss, the lowest blood pressure above $32^{\circ}C$, under-clothing temperature, and thermal sensation increased when in slacks to be compared with when in skirt. 3. Ambient temperature had a great effect on mean skin temperature, body weight loss, respiration, clothing surface temperature, under-clothing temperature and humidity, thermal sensation, etc. 4. It was admitted that pulse, thermal sensation, comfort show different individuality. 5. It was recognized that the lowest blood pressure, clothing surface temperature, under. clothing humidity differ according to the kinds of clothing. 6. A comfortable ambient temperature in clothing summer wear was about $27\~28^{\circ}C$.

  • PDF

여름용 경찰 근무복 상의 선호도 분석 및 디자인 개발 (Analysis of Preferences and Developments of Police Officers' Upper Uniform for Summer Weather)

  • 박소진;구수민;김효원;이영빈;권유미
    • 한국의류학회지
    • /
    • 제43권6호
    • /
    • pp.837-855
    • /
    • 2019
  • The need of development of police officers' uniforms for the summer season has increased due to rises in temperature. This research developed a t-shirt typed of police officer's uniform for summer weather. We analyzed the design cases of national and international police officers' uniforms, similar types of uniforms, and t-shirts for summer weather. The satisfaction with current uniforms and preferences for these types of uniforms were surveyed with 1,062 police officers and public participants. Designs were developed and design opinions were surveyed with 1,011 public volunteers. A total of 584 police officers wore developed prototypes for two weeks, and surveys were conducted with 328 police officers to reflect the final design results. More than 80% of police officers have very satisfied or satisfied opinions of the developed designs. The study is expected to enhance police officers' satisfaction with the developed uniforms for summer weather.

대한민국 동하절기 해군 함상복의 착용쾌적성 평가를 통한 디자인 요소 요구성능 분석 (Design Requirements by Evaluating Comfort while Wearing Korean Naval Duty Uniforms for Summer and Winter)

  • 이효현;신소라;이주영
    • 한국지역사회생활과학회지
    • /
    • 제27권3호
    • /
    • pp.419-435
    • /
    • 2016
  • The purpose of the present study was to suggest the design requirements for Korean naval duty uniforms by evaluating the physiological and psychological comfort while wearing the uniforms. Two sets of wear trials were conducted with summer uniforms(eight young males) and winter uniforms(seven other young males). The summer wear trial consisted of 10-min rest, 60-min exercise, and 10-min recovery at an air temperature($T_{air} $) of $33^{\circ}C$ and 62%RH, followed by 10-min recovery at a $T_{air} $ of $23^{\circ}C$ and 64%RH(total 90 min). The winter wear trial consisted of 20-min rest at $T_{air} $ $20^{\circ}C$ and 55%RH, 25-min rest, 30-min exercise, and 35-min recovery at a $T_{air} $ of 0oC and 43%RH(total 110 min). Rectal and seven skin temperatures, clothing microclimate, heart rate, oxygen consumption, total sweat rate, and subjective perceptions were measured during the wear trials. By evaluating the experimental results from the wear trials, we extracted the following psycho-physiological design requirements to improve the current Korean naval uniforms: (1) It is important to maintain the skin temperatures within their comfort range, which depends on the body region (higher than $30^{\circ}C$ in winter, but less than $35^{\circ}C$ in summer). (2) In summer, the feet should be protected from the high heat of the ship floor surface. (3) In summer, sweat from the back should be sufficiently absorbed and allowed to dry quickly.

통기성 향상을 위한 하계비행복 설계 및 착용쾌적성 평가 (Wearing Comfort Evaluation of a Summer Flight Suit to Improve Ventilation)

  • 전은진;박세권;유희천;김희은
    • 한국의류산업학회지
    • /
    • 제16권3호
    • /
    • pp.485-491
    • /
    • 2014
  • This study verified the effect of summer flight ventilation developed in a previous study based on wearing comfort evaluation. Seven healthy males in their twenties volunteered for this experiment conducted in aclimatic chamber. The experiment consisted of three consecutive periods of rest (20 minutes), running on a treadmill (10 minutes) and recovery (20 minutes). A comparative evaluation was conducted on the general flight suit which had no ventilation holes and summer flight suit that use subjective satisfaction measures and objective measures. The subjective satisfaction was evaluated according to the criteria of temperature sensation, wet sensation, thermal comfort and fatigue sensation. The objective satisfaction was measured by skin temperature, microclimate (temperature and humidity), sweat rate and thermography. The comparative wearing evaluation identified the summer flight suit decreased the temperature between skin and suit by $0.42^{\circ}C$ (upper arm), $0.9^{\circ}C$ (calf) and the skin temperature by $0.3^{\circ}C$ (shoulder), $0.4^{\circ}C$ (upper arm), $0.5^{\circ}C$ (calf) as compared to the general flight suit. The humidity inside the summer flight suit decreased at head (7.73%), shoulder (5.86%), upper arm (5.26%), and calf (8.73%) compared to the one inside the general flight suit. Thermography showed that the air flowed through ventilation holes (neck and armpit). The design of ventilation holes applied to the summer flight suit can be applicable to overall clothing that requires thermal comfort such as dust-free garments, mechanical clothing and combat uniforms.

하절기 유리온실의 증발냉각 설계기준을 위한 VETH 선도 연구 (Studies of VETH Plot for Standard Design of Evaporative Cooling at Summer Glasshouse)

  • 우영회;안율균;김동억
    • 현장농수산연구지
    • /
    • 제20권1호
    • /
    • pp.55-66
    • /
    • 2018
  • 하절기 하우스 온도환경의 효율적 제어는 온실의 주년재배와 고도 활용을 위한 가장 중요한 당면과제이다. 본 연구는 여름철 지역별 하우스 증발냉각을 위한 설계 기준안으로서 9개 지역(서울, 서산, 대전, 부산, 제주, 광주, 대구, 전주, 진주)의 VETH 선도를 작성하여 제시하였다.

생활한복형 하절교복의 의복기후와 주관적 감각 (The Clothing Microclimates and Subjective Sensation for Casual Hanbok as School Summer Uniform)

  • 유정자;권수애
    • 한국생활과학회지
    • /
    • 제21권4호
    • /
    • pp.765-780
    • /
    • 2012
  • This study was investigated the clothing microclimate, subjective sensation for the improvement of traditional koran high school student uniform so called "Saenghwal Hanbok". For the purpose, casual hanbok school summer uniforms were made. They were made of 4 different textiles materials - P/R, P100, P/C, P/R/S for blouses, P/W, P100, P/R, P/W/F for skirts. Then their clothing microclimate, subjective sensation were tested at room temperature $25{\pm}1^{\circ}C$ and $50{\pm}10%$ R.H. Clothing Microclimates wearing on the blouses were good matched comfort temperature range. Subjective sensations wearing on the blouses were better than those of traditional koran clothes so called "Hanbok" and quite same for western style clothes. Thermal sensations were indicated some hot condition, and moisture sensations were indicated some wet condition but tactile sensations and comfortable sensations were agreeable. The temperatures of the forehead and the breast wearing on the skirts were indicated the same results with the cases of the blouses. Leg temperatures were some lower than the mean skin temperature, the other parts' temperatures were slightly higher than blouses but the mean skin temperatures were satisfied comfortable ranges. Subjective sensations wearing on the skirts were better than those of the other traditional clothes and even Western clothes. Thermal sensations and moisture sensations were resulted the same with the case of blouses. Currently, P/R material and P/W material seemed to be cool and respectively suitable for blouses and skirts in summer among the materials of modernized Korean traditional costumes and school uniforms, since those materials lowered skin temperature. But better, physiologically pleasant materials for summer clothes should be development in consideration of clothing microclimate and subjective sensation.

공동주택의 하절기 결로 방지에 대한 연구 (A Study on Anti-Condensation of the Apartment Building in Summer)

  • 김승범;서희창;김주형;김재준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2012
  • Moisture condensation leading to defects that occur repeatedly in the winter, and recognize the same method, the problem of the other buildings in the same area again and again, a vicious cycle that occurs due to the temporary lack of systematic research and processing way of coping has been recurring. In this study, as warming progresses, more inside the air-conditioned summer season due to an increase in the ambient temperature of the condensation phenomenon to happen about summer wall condensation phenomena are expected to analyze the case of a building to prevent condensation and for insulation designs are proposed.

  • PDF

한국 전통주거의 기류 분석을 통한 자연통풍 설계 연구 (Natural Ventilation Planning by Analysis on Air Velocity Property of a Traditional Korean House)

  • 최윤정;김인선;허범팔
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.117-120
    • /
    • 2001
  • This study is a preliminary research to develop design principles for environmentally friendly housing. The purposes of study are to investigate the literatures related passive design for summer and theory of ventilation, to analyze the indoor airflow patterns in traditional Korean house during summer, and to propose the design factors for effective passive cooling system. The analysis for airflow patterns was focused on the ‘An bang’and the ‘Dae Chung’in the ‘An Chae’of a traditional house located in Seoul. Field measurements of air temperature and air velocity were carried out at 30 different measuring points with 8 different window-opening conditions. The measurements were taken on the hottest summer days in August 2000. It is concluded that from an environmentally friendly standpoint design factors to control indoor thermal environment by a passive cooling system during the summer are as follows; ceiling structure has thermal performance like a time-lag effect, optimum height and length of eaves which can prevent sunlight and divert airflow toward the sitting level, building arrangement acceptable the prevailing wind, strategic window arrangement which makes cross ventilation possible (especially north-south) at the sitting level, window opening condition which is possible to intersect two cross-ventilation stream at the main living areas, northward windows remaining in shade to create the air pressure difference, and planning building shape like a bracket that has optimum width and depth.

  • PDF

Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems

  • Song, J.I.;Park, K.H.;Jeon, J.H.;Choi, H.L.;Barroga, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권3호
    • /
    • pp.433-442
    • /
    • 2013
  • This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The $NH_3$ concentration of both housing systems was also investigated in relation to the pig's growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to $29.1^{\circ}C$ during summer and 17.9 to $23.1^{\circ}C$ during winter whilst the CPH had a wider temperature variance during summer at 24.7 to $32.3^{\circ}C$. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to $18.2^{\circ}C$. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.

여름철 원피스드레스 안감소재에 따른 온열적 생리반응과 주관적 착용감 (Thermophisiological Responses and Wearing Comfort of the Lining Fabrics of Summer One Piece Dress)

  • 권수애;최종명;김인화
    • 한국생활과학회지
    • /
    • 제14권4호
    • /
    • pp.645-651
    • /
    • 2005
  • The purpose of the study was to investigate the thermophisiological responses and subjective wearing comfort for the six lining fabrics of one-piece dress in summer environment. There were significant differences in the microclimate, the mean skin temperature and the subjective wear comfort for the lining fabrics. The mean skin temperature of rayon and acetate were lower than that of synthetic fiber. The wearing comfort of rayon and acetate were better than that of synthetic fiber. There were clear correlations between the mechanical properties and the subjective wear comfort of lining fabrics. The hygroscopicity and density of textile affected the humidity and tactile sensation of dress, and they were important factors determining the wearing comfort of one-piece dress.

  • PDF