• 제목/요약/키워드: sum of temperature

검색결과 225건 처리시간 0.023초

사출금형의 균일 냉각을 위한 냉각회로의 다중목적함수 최적설계 (Multi-objective Optimization of an Injection Mold Cooling Circuit for Uniform Cooling)

  • 박창현;박정민;최재혁;이병옥;최동훈
    • 한국자동차공학회논문집
    • /
    • 제20권1호
    • /
    • pp.124-130
    • /
    • 2012
  • An injection mold cooling circuit for an automotive front bumper was optimally designed in order to simultaneously minimize the average of the standard deviations of the temperature and the difference in mean temperatures of the upper and lower molds for uniform cooling. The temperature distribution for a specified design was evaluated by Moldflow Insight 2010, a commercial injection molding analysis tool. For efficient design, PIAnO (Process Integration, Automation and Optimization), a commercial PIDO tool, was used to integrate and automate injection molding analysis procedure. The weighted-sum method was used to handle the multi-objective optimization problem and PQRSM, a function-based sequential approximate optimizer equipped in PIAnO, to handle numerically noisy responses with respect to the variation of design variables. The optimal average of the standard deviations and difference in mean temperatures were found to be reduced by 9.2% and 56.52%, respectively, compared to the initial ones.

건구온파를 오인한 장기최대전력수요예측에 관한 연구 (Long-Term Maximum Power Demand Forecasting in Consideration of Dry Bulb Temperature)

  • 고희석;정재길
    • 대한전기학회논문지
    • /
    • 제34권10호
    • /
    • pp.389-398
    • /
    • 1985
  • Recently maximum power demand of our country has become to be under the great in fluence of electric cooling and air conditioning demand which are sensitive to weather conditions. This paper presents the technique and algorithm to forecast the long-term maximum power demand considering the characteristics of electric power and weather variable. By introducing a weather load model for forecasting long-term maximum power demand with the recent statistic data of power demand, annual maximum power demand is separated into two parts such as the base load component, affected little by weather, and the weather sensitive load component by means of multi-regression analysis method. And we derive the growth trend regression equations of above two components and their individual coefficients, the maximum power demand of each forecasting year can be forecasted with the sum of above two components. In this case we use the coincident dry bulb temperature as the weather variable at the occurence of one-day maximum power demand. As the growth trend regression equation we choose an exponential trend curve for the base load component, and real quadratic curve for the weather sensitive load component. The validity of the forecasting technique and algorithm proposed in this paper is proved by the case study for the present Korean power system.

  • PDF

Fuzzy Inference Based Design for Durability of Reinforced Concrete Structure in Chloride-Induced Corrosion Environment

  • Do Jeong-Yun;Song Hun;Soh Yang-Seob
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.157-166
    • /
    • 2005
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and water-cement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

다기능성을 가진 음성 인식 요람 연구 (Study on the multi-functional Cradle by Voice Recognitions)

  • 박광성;안상진;조경록;최시온;박용욱
    • 한국전자통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.701-706
    • /
    • 2017
  • 본 연구에서는 요람을 기존의 리모컨이나 수동으로 구동하는 방식과 달리 APP을 통하여 사람의 음성을 인식하면 모터로 동작하도록 요람을 제작하였다. 또한 요람에 온습도센서를 장착하여 실시간으로 요람의 온도와 습도를 LCD를 통해서 확인할 수 있고, 또한 소리크기에 따라 결과 값을 가지는 사운드센서를 이용하여 결과 값을 a, b, c로 지정하여 이 결과 값의 합이 1150을 넘으면 아기의 울음소리로 인식하여 APP에 알림표시와 알림음이 작동하도록 하는 기능을 가지는 요람을 제작하였다.

당량비 변화에 따른 복사 특성이 3차원 난류 연소에 미치는 영향 연구 (Study of the Radiation Effect by Equivalence ratio change on the 3-D Turbulent Combustion)

  • 김태국;윤경범;민동호;장희철;김진수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.79-85
    • /
    • 2006
  • Radiative heat transfer is very important in many combustion systems since they are operated in high temperature. Fluid flows in most of the combustion systems are turbulent to promote fast mixing of the hydrocarbon fuel and oxidant. Major combustion products are $CO_2$ and $H_2O$. The turbulent flow is modeled by using the standard ${\kappa}-{\epsilon}$ model and the radiation transfer is modeled by using the discrete ordinates method where the radiative gas properties are calculated by using the weighted sum of gray gases model with a gray gas regrouping(WSGGM-RG). Effect of the radiation on the combustion characteristics in a three-dimensional rectangular enclosure is studied by changing the equivalence ratio. Results show that the radiation plays a significant role on the heat transfer in the combustion systems by resulting in a temperature drop of 16% as compared to that obtained without radiation. The equivalence ratio also affects the combustion by different contribution of the radiative transfer with different gas compositions.

  • PDF

극저온 냉동기로 냉각되는 이중전류도입선의 최적설계 (Optimal design of binary current leads cooled by cryogenic refrigerator)

  • 송성재;장호명
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.552-560
    • /
    • 1997
  • Analysis is performed to determine the optimal lengths or cross-sectional areas of refrigerator-cooled current leads that can be applied to the conduction-cooled superconducting systems. The binary current lead is composed of the series combination of a normal metal at the upper(warm) part and a high $T_c$ superconductor(HTS) at the lower(cold) part. The heat conduction toward the cold end of HTS part constitutes a major refrigeration load. In addition, the joint between the parts should be cooled by a refrigerator in order to reduce the load at the low end and maintain the HTS part in a superconducting state. The sum of the work inputs required for the two refrigeration loads needs to be minimized for an optimal operation. In this design, three simple models that depict the refrigeration performance as functions of cooling temperature are developed based on some of the existing refrigerators. By solving one-dimensional conduction equation that take into account the temperature-dependent properties of the materials, the refrigeration works are numerically calculated for various values of the joint temperature and the sizes of two parts. The results show that for given size of HTS, there exist the optimal values for the joint temperature and the size of the normal metal. It is also found that the refrigeration work decreases as the length of HTS increases and that the optimal size of normal metal is quite independent of the size of HTS. For a given length of HTS, there is an optimal cross-sectional area and it increases as the length increases. The dependence of the optimal sizes on the refrigerator models employed are presented for 1kA leads.

  • PDF

복합사이클 발전플랜트 폐열회수 보일러의 구성요소 크기비의 최적화 (Ratio Optimization Between Sizes of Components of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants)

  • 인종수;이상용
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.403-410
    • /
    • 2009
  • This paper proposes a new approach to find the optimum ratios between sizes of the heat exchangers of the heat recovery steam generator (HRSG) system with limited size to maximize the efficiency of the steam turbine (bottom) cycle of combined cycle power plants (CCPP), but without performing the bottom cycle analysis. This could be achieved by minimizing the unavailable exergy (the sum of the destroyed and the lost exergies) resulted from the heat transfer process of the HRSG system. The present approach is relatively simple and straightforward because the process of the trial-and-error method, typical in performing the bottom cycle analysis for the system optimization, could be avoided. To demonstrate the usefulness of the present method, a single-stage HRSG system was chosen and the optimum evaporation temperature was obtained corresponding to the condition of the maximum useful work. The results show that the optimum evaporation temperature based on the present exergy analysis appears similar to that based on the bottom cycle analysis. Also shown is the dependency of size (NTU) ratios between the heat exchangers on the inlet gas temperature, which is another important factor in determining the optimum condition once overall size of the heat recovery steam generator is given. The present approach turned out to be a useful tool for optimization of the singlestage HRSG systems and can easily be extended to multi-stage systems.

2Y-TZP 분말내 준안정 정방정상 입자의 전이도 및 상전이거동 (Transformability and Phase Transformation Behaviors of Metastable Tetragonal Phase in 2Y-TZP Powder.)

  • 김환;이종국
    • 한국재료학회지
    • /
    • 제2권5호
    • /
    • pp.320-329
    • /
    • 1992
  • 2mol%의 이트리아로 안정화된 정방정상 지르코니아 분말을 80$0^{\circ}C$부터 150$0^{\circ}C$ 까지 온도별로 열처리하여 분말내 입자크기 및 입자간에 존재하는 구속력을 변화시킨 다음, 정방정상의 전이도 및 안정화효과가 무열상전이, 응력유기상전이, 등온상전이 에 미치는 영향을 고찰하였다. 그 결과 Y-TZP 분말내 정 방정상의 전이도는 고용체의 양이 일정할 경우 열처리온도의 변화에 따른 입자크기와 입자간에 존재하는 구속력의 크기에 의존하였는데 열처리온도가 증가함에 따라 전이도가 점차 증가하여 130$0^{\circ}C$로 열처리한 분말에서 최대값을 보였다. 그러나 130$0^{\circ}C$ 이상으로 열처리한 분말에서는 열처리온도가 증가함에 따라 구속효과의 증가에 따라 전이도가 정차로 감소하였다. 전이도가 큰 분말에서는 정방정상이 무열상전이, 응력유기상전이, 등온상전이를 쉽게 일으켜 단사정상으로 전이하였다.

  • PDF

기온자료에 근거한 주요 포도품종의 휴면해제 및 발아시기 추정 (Prediction of Dormancy Release and Bud Burst in Korean Grapevine Cultivars Using Daily Temperature Data)

  • 권은영;송기철;윤진일
    • 한국농림기상학회지
    • /
    • 제7권3호
    • /
    • pp.185-191
    • /
    • 2005
  • An accurate prediction of dormancy release and bud burst in temperate zone fruit trees is indispensable for farmers to plan heating time under partially controlled environments as well as to reduce the risk of frost damage in open fields. A thermal time-based two-step phenological model that originated in Italy was applied to two important grapevine cultivars in Korea for predicting bud-burst dates. The model consists of two sequential periods: a rest period described by chilling requirement and a forcing period described by heating requirement. It requires daily maximum and minimum temperature as an input and calculates daily chill units (chill days in negative sign) until a pre-determined chilling requirement for rest release is met. After the projected rest release date, it adds daily heat units (anti-chill days in positive sign) to the chilling requirement. The date when the sum reaches zero isregarded as the bud-burst in the model. Controlled environment experiments using field sampled twigs of 'Campbell Early' and 'Kyoho' cultivars were carried out in the vineyard at the National Horticultural Research Institute (NHRI) in Suwon during 2004-2005 to derive the model parameters: threshold temperature for chilling and chilling requirement for breaking dormancy. The model adjusted with the selected parameters was applied to the 1994-2004 daily temperature data obtained from the automated weather station in the NHRI vineyard to estimate bud burst dates of two cultivars and the results were compared with the observed data. The model showed a consistently good performance in predicting the bud burst of 'Campbell Early' and 'Kyoho' cultivars with 2.6 and 2.5 days of root mean squared error, respectively.

Invasion of Ambrosia artemisiifolia L. (Compositae) in the Ukrainian Carpathians Mts. and the Transcarpathian Plain (Central Europe)

  • Song, Jong-Suk;Prots, Bohdan
    • Animal cells and systems
    • /
    • 제2권2호
    • /
    • pp.209-216
    • /
    • 1998
  • The invasion of Ambrosia artemisiifolia in the Ukrainian Carpathians Mts. and the Transcarpathian Plain in Central Europe was reconstructed on the basis of floristic records. The first spontaneous occurrence was dated from the beginning of the 1940s. Within the next 55 year period, the distributional spread speed of the species was of 67.6 $km^2/y$ (by the average data). The occupied area by A. artemisiifolia in the range of the studied areas is about $3716.5km^2$ now. The features of behavior of the invader and the habitat preference were determined. The frequency of occurrence by sociologic-ecological classification was carried out. The generalized model of correlations among the gravitation, the active temperature sum and the disturbance gradients and the frequency of occurrence of the species was presented. The scheme of the invasion stages of A. artemisiifolia is reflected in the population status changes of the species during the areal dynamics.

  • PDF