• 제목/요약/키워드: sum of temperature

검색결과 225건 처리시간 0.02초

야간투시경용 영상증폭관(KIT-7)의 가속수명시험에 관한 연구 (A STUDY ON THE ACCELERATED LIFE TESTS OF IMAGE INTENSIFIER ASSEMBLY(KIT-7))

  • 김성민;박정원;함중걸;김광연
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권3호
    • /
    • pp.127-136
    • /
    • 2007
  • The accelerated life tests(ALTs) and degradation characteristics of image intensifier assembly(KIT-7) under low illuminance and high temperature were investigated. The accelerated life tests were carried out at $5{\times}10^5\;fc-40^{\circ}C,\;10{\times}10^5\;fc-40^{\circ}C,\;5{\times}10^5\;fc-50^{\circ}C,\;10{\times}10^5\;fc-50^{\circ}C$ and relationship related to illuminance and temperature was used as an accelerated life test model. An ALTA program[6] was used to calculate an acceleration factor and the test of life distribution fit, and estimate three parameters of an life test model. To sum up, MTTF 10,000 h at $5{\times}10^{-5}\;fc-40^{\circ}C$ of image intensifier assembly was certificated.

  • PDF

슬래브축열의 최적제어방책에 관한 연구 -평가함수의 선택이 결과에 미치는 영향- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - Results Influenced by the Choice of a Criterion Function -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.896-905
    • /
    • 2006
  • An optimal control of an air-conditioning system with slab thermal storage is investigated by making use of the Maximum Principle. An optimal heat input to a plenum chamber and an air-conditioned room is determined by minimizing a criterion function which is given as integral sum of two terms. The first term is the square of the deviation in the room air temperature from the set-point value, and the second is the absolute value of the heat input. The result indicates that it tries to keep a room air temperature in set-point value by heating as much as possible at the time of a setup of a room air temperature or just before that, in order to avoid a heat loss arising at the time of the non-air conditioning. The result is compared with that of the case when the square of the heat input is used as a criterion.

The Distribution Characteristics of Polychlorinated Biphenyls in Rural Atmosphere

  • Yeo, Hyun-Gu;Park, Minkyu;Chun, Man-Young;Young Sunwoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E3호
    • /
    • pp.143-151
    • /
    • 2002
  • Atmospheric concentrations of polychlorinated biphenyl (PCB) congeners were measured every two weeks from July, 1999 to January, 2000 at Hankyong University in Ansung, Kyounggi-do. Atmospheric concentrations of ∑$_{24}$PCB showed a range of 19.8~71.9 pg/m3. The highest concentration of PCB homolog was tri-CBs (sum of PCB 18, 27, 28, 33, 38) which had a comparatively higher vapor pressure than other homologs. The contribution ratio of lighter PCB homologs (tri-CBs) to total PCBs was 44.5%, and these homologs were the main components of PCBs. The ratio PCB homologs/deca-CB (PCB 209) suggested that the contribution of vapor phase PCBs increased greatly in summer relative to other seasons. In addition, the regression lines for PCB homologs/deca-CB (PCB 209) and temperature ($^{\circ}C$) appeared as an exponential function with high correlation (R2>0.67, p< 0.01). This suggests that the concentration of vapor phase PCB homologs increases steeply with increasing temperature.

Improvement of COMS Land Surface Temperature Retrieval Algorithm

  • Hong, Ki-Ok;Suh, Myoung-Seok;Kang, Jeon-Ho
    • 대한원격탐사학회지
    • /
    • 제25권6호
    • /
    • pp.507-515
    • /
    • 2009
  • Land surface temperature (LST) is a key environmental variable in a wide range of applications, such as weather, climate, hydrology, and ecology. However, LST is one of the most difficult surface variables to observe regularly due to the strong spatio-temporal variations. So, we have developed the LST retrieval algorithm from COMS (Communication, Ocean and Meteorological Satellite) data through the radiative transfer simulations under various atmospheric profiles (TIGR data), satellite zenith angle (SZA), spectral emissivity, and surface lapse rate conditions using MODTRAN 4. However, the LST retrieval algorithm has a tendency to overestimate and underestimate the LST for surface inversion and superadiabatic conditions, respectively. To minimize the overestimation and underestimation of LST, we also developed day/night LST algorithms separately based on the surface lapse rate (local time) and recalculated the final LST by using the weighted sum of day/night LST. The analysis results showed that the quality of weighted LST of day/night algorithms is greatly improved compared to that of LST estimated by original algorithm regardless of the surface lapse rate, spectral emissivity difference (${\Delta}{\varepsilon}$) SZA, and atmospheric conditions. In general, the improvements are greatest when the surface lapse rate and ${\Delta}{\varepsilon}$ are negatively large (strong inversion conditions and less vegetated surface).

전도냉각형 펠티어 전류도입선의 최적화 (Optimization of Conduction-cooled Pottier Current Leads)

  • 정은수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

평판형 태양열 집열기의 각도에 따른 집열성능 연구 (Study on the Heat Collecting Performance of Flat-Plate Solar Collector by the angle)

  • 지명국;공태우;배철환;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.316-321
    • /
    • 2000
  • In this study, heat collecting performance was study of flat plate solar collector by the angle. A method of study on were made turn out artificial sun by the angle of 0, 15, 30 degrees. The heat performances were measured the tube array surface temperature by thermo-couple. The winter season natural condition for 4 times on the angles of various general and emboss glass at optimum distance(0.68m) calculated of between sun and solar collector. To sum up temperature rise is appear more or less that emboss glass is all the better for general glass. The temperature variable at below of 30 degree was appear very less. The maximum performance of this system at that it is tilt angle of 30 with general glass is appear Q:11.54(kcal/min) and ${\Delta}T=18.9^{\circ}C$.

  • PDF

레이저유도 형광법을 이용한 화염내 OH 농도분포 계측 (Hydroxyl Radical Measurements in the Flame Using LIF)

  • 이병준;길용석;정석호
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.710-719
    • /
    • 1996
  • Laser applied combustion diagnostic techniques-laser induced fluorescence (LIF) and coherent anti-Stokes Ramann spectroscopy (CARS)-are demonstrated. The profiles of hydroxyl radical (OH) and temperature in the counterflow burner are measured and compared with the numerical results. OH radical is excited on the Q$_1$(6) line of the $A^2$$\sum^+$$\leftarrow$$X^2{\prod}$(1, 0) band transition (281.1 nm) and LIF signal is measured at the the bands of (0, 0) and (1, 1) transition (306~326 nm). Absolute OH radical is obtained by using the laser absorption technique. The quenching effects are considered. Temperature is measured using broadband CARS system. Two dimensional OH radical profile is also obtained. The profiles of OH radical and temperature are found to agree well with those of numerical calculation.

Size Variation and Cyclomorphosis of the Rotifer, Brachionus rotundiformis, Isolated from Cheju island, Korea

  • Song, Choon-Bok;Kim, Yeon-Hee;Lee, Je-Hee;Rho, Sum
    • 한국양식학회지
    • /
    • 제12권4호
    • /
    • pp.267-274
    • /
    • 1999
  • A rotifer starin has been isolated from tide pools located near Sogwipo, Cheju Island and the effects of environmental factors (water temperature and salinity) and clonal differences have been examined with regard to size variation and cyclomorphosis. Adult female rotifers varied from 141.61 to $173.97 \mutextrm{m}$ in their mean lorica length under different rearing conditions in the laboratory and also had pointed anterior spines . Thus, this strain was classified as Brachionus rotundiformes. Mean lorica length tended to be smaller as rearing temperature increased although there were some exceptions. Statistical analysis indicated that lorica length was largely influenced by both clonal differences and rearing temperatures although the former as a genetic factor affected lorica length a little more than the latter did ; overall effect of salinity on lorica length was not statistically signicicant; furthermore, cyclomorphosis was also largely influenced by both clonal differences and rearing temperatures, but clonal differences as a genetic factor affected rotifer cyclomorphosis much more than temperature did.

  • PDF

미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구 (A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.

아트리움 공간에서 화재발생시 복사열전달의 영향 분석 (Effects of Radiation Heat Transfer on the Fire in an Atrium)

  • 윤경범;장희철;김태국
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.18-24
    • /
    • 2007
  • 본 연구는 아트리움 방호공간에서 화재발생시 복사열전달의 유무에 따른 유동장 및 온도분포의 예측을 목적으로 수치해석을 수행하였다. 화재모델로 Field 모델을 사용하였으며 난류 모델로 SIMPLE 알고리즘이 적용된 표준 $k-{\varepsilon}$ 모델을 사용하였다. 복사열전달 해석에 필요한 복사물성치의 계산은 속도를 단축하며 정확성을 유지하는 WSGGM-RG를 사용하였다. 난류유동장과 복사열전달의 계산은 자체 개발된 CCRHT-3D 프로그램을 사용하였다. 해석결과에 의하면 화재지점을 제외하고 아트리움의 천장부가 높은 온도분포로 나타났다. 유동과 온도의 분포가 출입문 방향으로 편향되고 화재의 위치에서 아트리움의 천장과 벽에 가까워질수록 온도가 낮아지는 경향을 보였다. 이러한 결과는 천장 스프링클러헤드의 작동 시점을 예측하는데 복사열의 영향이 크다는 것을 의미하게 된다.