• Title/Summary/Keyword: sulfuric acid-resistant

Search Result 13, Processing Time 0.029 seconds

Service Life Prediction of Concrete Structures Exposed to a Sulfuric Acid Environment

  • Jeon, Joong-Kyu;Moon, Han-Young;Jeon, Chan-Ki;Song, Jong-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.385-389
    • /
    • 2007
  • In this study, it was investigated the resistance of OPC, 60% GGBS, 20% PFA and 10% SF mortar specimens against sulfuric acid corrosion. As an index for degree of acid corrosion, the corrosion depth was evaluated. Then, it was found that an increase in the duration of immersion and a decrease in the pH, as expected, resulted in a more severe corrosion irrespective of binders; 60% GGBS mortar specimen was the most resistant to sulfuric acid corrosion. From the laboratory testing of sulfuric acid corrosion, an empirical prediction model was suggested as a power function of time and the pH of sulfuric acid, and was applied to an assessment of concrete structures exposed to an acidic environment. It was found that the empirical model gave a more precise prediction of sulfuric acid deterioration of concrete rather than a conventional model, mostly used for predicting carbonation of concrete.

Effect of Ground Granulated Blast Furnace Slag, Pulverized Fuel Ash, Silica Fume on Sulfuric Acid Corrosion Resistance of Cement Matrix

  • Jeon, Joong-Kyu;Moon, Han-Young;Ann, Ki-Yong;Kim, Hong-Sam;Kim, Yang-Bea
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.2E
    • /
    • pp.97-102
    • /
    • 2006
  • In this study, the effect of supplementary materials(GGBS, PFA, SF) on sulfuric acid corrosion resistance was assessed by measuring the compressive strength, corroded depth and weight change at 7, 28, 56, 91, 180 and 250 days of immersion in sulfuric acid solution with the pH of 0.5, 1.0, 2.0 and 3.0. Then, it was found that an increase in the duration of immersion and a decrease in the pH, as expected, resulted in a more severe corrosion irrespective of binders: increased corroded depth and weight change, and lowered the compressive strength. 60% GGBS mortar specimen was the most resistant to acid corrosion in terms of the corroded depth, weight change and compressive strength, due to the latent hydraulic characteristics and lower portion of calcium hydroxide. The order of resistance to acid was 60% GGBS>20% PFA>10% SF>OPC. In a microscopic examination, it was found that acid corrosion of cement matrix produced gypsum, as a result of decomposition of hydration products, which may loose the structure of cement matrix, thereby leading to a remarkable decrease of concrete properties.

A Study on Resistant Comparisons of Landscape Trees by Simulated Acid Rain (인공산성우에 대한 조경수목의 내성 비교)

  • 정용문
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.208-218
    • /
    • 1991
  • To compare the resistance of landscape trees by acid rain, simulated acid rain was treated on the seeds of 6 coniferous species (Pinus densiflora, Pinus thunbergii, Pinus koraiensis, Taxus cuspidata, Cedrus deodara, Thuja occidentalis) and 6 broad-leafed species (Ligustrum obtusifolium, Acer Buergerianum, Acer Ginnala, Styrax obassia, Cornus Kousa, Magnolia obovata). The experimental design of randomized block arrangement with three replications was implemented in the experimental field of Yesan National Agri-Tech Junior College. The seeds of 12 tree species were planted on the nursery soil in the early spring of 1991. The regime of artificial acid rain, in terms of spray frequency per monthly and spray amount at year records. Simulated acid rain (pH 2.0, pH 4.0, pH 5.6 as control) containing sulfuric and nitric acid in the ratio of 3:2 (chemical equivalant basis) diluted ground water, were treated on the experimental plants under condition of cutting off the natural precipitation with vinyl tunnel, during the growing season (April 8 to August 31) in 1991. Seedling establishment, seedling growth and nutrient contents in needles and leaves were measured and compared among the treatment. The results were summerized as follows; 1. In general, coniferous species were more resistant than broad-leafed species in the resistant comparisons of landscape trees by simulated acid rain. But there were resistant tree species to acid rain among the broad-leafed species. 2. Among 6 coniferous species used in this experiment, Pinus densiflora, Pinus koraiensis, Taxus cuspidata, Cedrus deodara and Pinus thunbergii revealed the resistant tree species to acid rain. But Thuja occidentalis was very susceptible to acid rain, because of no germination in pH 2.0 treatment plot of acid rain. 3. Among 6 broad-leafed species used in this study, Magnolia obovata, Styrax obassia and Ligustrum obtusifolium showed relative resistant tree species to acid rain. But Acer Buergerianum, Acer Ginnala and Cornus Kousa were very susceptible to acid rain, because of no germination in pH 2.0 plot of acid rain treatment.

  • PDF

Influence of Mineral Admixtures on the Resistance to Sulfuric Acid and Sulfate Attack in Concrete (콘크리트의 황산 및 황산염 침투 저항성에 미치는 광물질 혼화재의 영향)

  • Bae, Su-Ho;Park, Jae-Im;Lee, Kwang-Myong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.219-228
    • /
    • 2010
  • It has been well known that concrete structures exposed to acid and sulfate environments such as sewer, sewage and wastewater, soil, groundwater, and seawater etc. show significant decrease in their durability due to chemical attack. Such deleterious acid and sulfate attacks lead to expansion and cracking in concrete, and thus, eventually result in damage to concrete matrix by forming expansive hydration products due to the reaction between portland cement hydration products and acid and sulfate ions. Objectives of this experimental research are to investigate the effect of mineral admixtures on the resistance to acid and sulfate attack in concrete and to suggest high-resistance concrete mix against acid and sulfate attack. For this purpose, concretes specimens with three types of cement (ordinary portland cement (OPC), binary blended cement (BBC), and ternary blended cement (TBC) composed of different types and proportions of admixtures) were prepared at water-biner ratios of 32% and 43%. The concrete specimens were immersed in fresh water, 5% sulfuric acid, 10% sodium sulfate, and 10% magnesium sulfate solutions for 28, 56, 91, 182, and 365 days, respectively. To evaluate the resistance to acid and sulfate for concrete specimens, visual appearance changes were observed and compressive strength ratios and mass change ratios were measured. It was observed from the test results that the resistance against sulfuric acid and sodium sulfate solutions of the concretes containing mineral admixtures were much better than that of OPC concrete, but in the case of magnesium sulfate solution the concretes containing mineral admixtures was less resistant than OPC concrete due to formation of magnesium silicate hydrate (M-S-H) which is non-cementitious.

A Study on the Characteristics of Inorganic Polymer Mortar for Concrete Sectional Rehabilitation (콘크리트 단면복구용 무기성 모르타르의 특성에 관한 연구)

  • Hwang, Tae-Ha;Song, Tae-Hyeob;Im, Chil-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.171-177
    • /
    • 2010
  • As concrete structures are exposed to chemical substances, damaged from salt, or progressed to the neutralization, the surface damage of the structures is generated timely fashion, resulting shortened service life. Especially, the sulfate erosion causes rapid surface defects, and the steel skeleton becomes corroded due to the water infiltration, generating stability deterioration of the concrete structure. In this study, the physical characteristics of the acid-resistant mortar with aluminosilicates was investigated in order to resolve problems of the acid resistance, one of the most serious problems of the cement type repair material. As the result of the experiment, the test specimen turned to exhibit almost equivalent physical characteristics with those of concrete sectional repair materials in terms of compressive and bending strengths. As both the cement sectional repair material and the test specimen were immerged in sulfuric acid solution to examine weight changes, the test specimens exhibited only 4% loss of their weights while the cement sectional repair materials reached at the level of 80% or above, proving the excellence acid resistant characteristics of the test specimens. Consequently, the physical characteristics of acid resistant mortar with aluminosilicates were revealed to be superior than those of concrete sectional repair materials. It can be utilized as a sectional repair material where the acidic erosion is anticipated.

Service life of concrete culverts repaired with biological sulfate-resisting mortars

  • Hyun-Sub, Yoon;Keun-Hyeok, Yang;Nguyen, Van Tuan;Seung-Jun, Kwon
    • Computers and Concrete
    • /
    • v.30 no.6
    • /
    • pp.409-419
    • /
    • 2022
  • The purpose of this study is to examine the effectiveness of biological repairing mortars on restoring the structural performance of a sewage culvert deteriorated by sulfate attack. The biological mortars were developed for protecting concrete structures exposed to sulfate attack based on the block membrane action of the bacterial glycocalyx. The diffusion coefficient of sulfate ions in the biological mortars was determined from the natural diffusion cell tests. The effect of sulfate-attack-induced concrete deterioration on the structural performance of culverts was examined by using the moment-curvature relationship predicted based on the nonlinear section lamina approach considering the sulfuric-acid-induced degradation of the structure. Typical analytical assessments showed that biological mortars were quite effective in increasing the sulfate-resistant service life of sewage culverts.

Electrical Resistance Characteristics of Conductive Cement Composite with Deterioration Damage (열화손상이 발생된 전도성시멘트복합체의 전기저항특성)

  • Kim, Young-Min;Lee, Gun Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.149-150
    • /
    • 2020
  • Granting self-sensing performance in a building is an important performance to ensure the degree of damage and safety of the building. Since the current research is being conducted in the state before deterioration loss occurs, it is necessary to confirm whether the self-sensing performance is maintained even in the damaged conductive cement composite. As part of the study, electrical resistance characteristics were analyzed in conductive cement composites in which freeze-thawing and chemical corrosion occurred. As a result, it was found that the change in electrical resistance value due to freeze-thawing was not as large as 1%, and chemical corrosion occurred. It was found that the change in electrical resistance value of the tested specimen increased by about 10%.

  • PDF

The Study of Corrosion Behavior for Solution and Aging Heat Treated Ti alloy (Ti 합금의 용체화열처리와 시효열처리에 따른 부식거동)

  • Baik, Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.138-144
    • /
    • 2016
  • Titanium is resistant to general corrosion and in sea water because of the passivity layer film on the surface of material, but may be attacked by environments that cause breakdown of the protective oxide layer including hydrochloric, sulfuric and phosphoric acids. In this study, the Ti alloys were solution heat treatment 5hours at $1066^{\circ}C$ and $966^{\circ}C$, and followed by aging heat treated, 1, 4, 8 and 16 hours in $500^{\circ}C$, $600^{\circ}C$ and $650^{\circ}C$ respectively. The heat treated specimens were measured micro Vicker's hardness, and then accomplished electrochemical polarization test for comparing corrosion in 1N sulfuric acid solution. Additionally, micro structures were taken for corrosion tested specimens. The results showed that corrosion resistance was higher in solution heat treated alloy than base and age heat treated metal. Measured corrosion resistants were increased as increasing aging heat treatment time and temperature.

Microstructure Characteristics of Conductive Cement Mortar with Deterioration Damage (열화손상이 발생된 전도성시멘트모르타르의 미세구조 특성)

  • Kim, Young-Min;Lee, Gun Cheol;Yun, Hyun Do;Kwon, Hyun Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.195-196
    • /
    • 2021
  • The pore distribution of the cement mortar mixed with carbon nanotubes was found to have a large number of pores at (370~80)㎛, and the distribution ratio was larger as the carbon nanotubes were mixed. However, the pores with a fine particle diameter of (10-0.5) ㎛ were found to be larger as the carbon nanotubes were incorporated. However, the distribution of pores of the test specimens of conductive cement mortar with deterioration damage was found to be distributed in a number of particle diameters of (500 to 100) ㎛ and (10 to 0.5) ㎛. It is judged that the particle diameter of the internal pores increased due to the damage. However, as the mixing ratio of the test specimen with carbon nanotubes increased, the distribution of voids was relatively lower than that of plain, and it was judged to have excellent resistance to deterioration damage.

  • PDF

Application of Cathodic Protection on Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.140-146
    • /
    • 2005
  • Fossil fired power plant produces the electric energy by using a thermal energy by the combustion of fossil fuels as like oil, gas and coal. The exhausted flue gas by the combustion of oil etc. contains usually many contaminated species, and especially sulfur-content has been controlled strictly and then FGD (Flue Gas Desulfurization) facility should be installed in every fossil fired power plant. To minimize the content of contaminations in final exhaust gas, high corrosive environment including sulfuric acid (it was formed during the process which $SO_2$ gas combined with $Mg(OH)_2$ solution) can be formed in cooling zone of FGD facility and severe corrosion damage is reported in this zone. These conditions are formed when duct materials are immersed in fluid that flows on the duct floors or when exhausted gas is condensed into thin layered medium and contacts with materials of the duct walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of those ducts. The frequent shut down and repairing works of the FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, corrosion problems have severely occurred in a cooling zone even though high corrosion resistant materials were used. In this work, a new technology has been proposed to solve the corrosion problem in the cooling zone of FGD facility. This electrochemical protection system contains cathodic protection method and protection by coating film, and remote monitoring-control system.