• 제목/요약/키워드: sulfate resistance

검색결과 239건 처리시간 0.029초

Effect of Surface Roughness, Thickness and Current Density on Surface Resistance of Electro-deposited Copper Layer

  • Kim, Y.M.;Cho, S.K.;Choi, Y.;Lee, J.Y.;Kim, M.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.179-179
    • /
    • 2013
  • Surface resistance of electro-deposited copper with its thickness, current density and surface roughness was determined by using a 4-point probe analyzer. The copper was prepared electrochemically on 316 stainless steel substrate in copper sulfate solution at the condition of $1A/dm^2$, 298 K, and 6.5 cm-electrode distance. The surface resistance of the copper sheet in the range of $0.93-0.97{\Omega}$ increased with the copper thickness in the range of $21-70{\mu}m$. The surface resistance in the range of $0.963-1.009{\Omega}$ also increased with current density in the range of $0.5-2A/dm^2$. The increased surface resistances corresponded to 11% for thickness and 25% for current density, respectively.

  • PDF

Characterizations of Cr-P-PTFE composite coatings electroplated from trivalent chromium-based bath

  • Park, Jong-Kyu;Byoun, Young-Min;Seo, Sun-Kyo;Park, Su-Young;Choi, Sun-Woo
    • Journal of Ceramic Processing Research
    • /
    • 제19권6호
    • /
    • pp.455-460
    • /
    • 2018
  • Chromium plating is a common surface treatment technique extensively applied in industry due its excellent properties which include substantial hardness, abrasion resistance, corrosion resistance, surface color, and luster. In this study, the effect of PTFE on corrosion behavior of Cr-P plating, low carbon steel substrates are electroplated in Cr(III) baths without and with PTFE. Trivalent chromium carbon plating was electroplated from trivalent chromium sulfate-based baths with different PTFE dispersion contents. The study focused on the microstructure, PTFE content, roughness, and corrosion resistance of the Cr-P-PTFE composite plating. Scanning electron microscopy and atomic force microscopy images showed a smoother plating and a decrease in the surface roughness of the electrodeposited. The results demonstrate that PTFE eliminates the cracks within plating by reducing internal stress. Therefore, the corrosion resistance of Cr-P-PTFE composite platings were better than that of Cr-P alloy platings.

콘크리트용 혼화재(混和材)로서 고로(高爐)슬래그 미분말(微粉末)의 품질(品質)에 대한 연구(研究) (A Study on the Quality of Ground Granulated Blast Furnace Slag as a Mineral Admixture for Concrete)

  • 문한영;최연왕
    • 대한토목학회논문집
    • /
    • 제14권4호
    • /
    • pp.721-728
    • /
    • 1994
  • 본 연구는 국내 제철소에서 산업부산물로 발생되는 고로슬래그 미분말을 콘크리트용 혼화재료로 사용 가능한지를 알아보기 위한 연구의 일환으로 고로슬래그 미분말 자체의 화학성분, 물리적 성질 등과 같은 품질에 대하여 분석 검토하였다. 아울러 고로슬래그 미분말을 몇 단계로 혼합한 모르터 및 콘크리트의 콘시스텐시와 각 재령별 압축강도 및 내약품성에 대하여 기초적인 실험을 실시해 본 결과 장기재령에서 압축강도가 증가되었으며, 약품에 대한 모르터의 저항성도 우수함을 알 수 있었다.

  • PDF

동결융해와 황산염의 복합작용을 받는 부순모래 모르타르의 기초 특성 평가 (Evaluation on Basic Properties of Crushed Sand Mortar in Freezing-Thawing and Sulfate Attack)

  • 김명식;백동일;최강석
    • 한국해양공학회지
    • /
    • 제23권5호
    • /
    • pp.54-60
    • /
    • 2009
  • Exposed to various environments, concrete confronts degradation by a lot of physical and chemical reaction. Though so many experiments and theorizations on the single condition of concrete degradation have been carried out by constant studies, the truth for now is that there are few studies on the compound phenomenon of degradation related with marine environments. Accordingly, this study measured the degree of degradation in the change of external shape, the change of unit weight and compressive strength, ultrasonic velocity test, and the change of length, etc. after exposing the specimen of cement mortar to the environment between 0 cycle and the maximum of 300 cycles under the condition of aquatic curing, freezing and thawing, and compound degradation, using mineral admixture effective for concrete degradation as a binder. The result indicated that the case of adding mineral admixture showed greater resistance than that of using OPC only, and specifically, the specimen with the additive of slag powder and three component system showed very excellent resistance to freezing and thawing, and compound degradation.

황산, 염소이온 반응 소재 혼입 수용액에서의 이온반응성 및 전기화학적 철근 부식에 관한 실험적 연구 (An Experimental Study on the Ion Reaction and the Electrochemical Rebar-Corrosion in Aqueous Solution Mixed with Sulfate and Chloride Ion-Reactive Material)

  • 류화성;신상헌;강태원;임창길;김홍태
    • 한국건축시공학회지
    • /
    • 제19권1호
    • /
    • pp.31-38
    • /
    • 2019
  • 본 연구에서는 하수 환경의 콘크리트 구조물(암거, 처리시설)용 보수재료의 요소기술로서 콘크리트 유해요인($SO{_4}^{2-}$, $Cl^-$)을 능동적으로 제어(고정, 반응)하는 아민유도체 및 이온교환수지를 대상으로, 시멘트세공용액을 모사한 수산화칼슘 수용액을 이용하여 이온 크로마토그래피 분석으로 유해요인 흡착성능을 확인하고, Potentiostat으로 철근 부식 저항성을 평가하였다. 실험결과, 아민유도체는 염소이온의 흡착, 이온교환수지는 황산이온의 흡착에 우수한 것으로 확인되었으며, 하수시설환경을 모사한 수용액에서 두 소재의 적절한 조합으로 부식 저항성을 증가시킬 수 있는 것을 확인하였다.

자동차 보호용 아크릴 점착제의 제조 및 내성조사 (Preparation and Resistant Property of Acrylic Adhesives for Automobiles Protection)

  • 함현식;박지영;안성환;김송형;홍석영;박홍수
    • 한국응용과학기술학회지
    • /
    • 제23권2호
    • /
    • pp.169-176
    • /
    • 2006
  • Acrylic adhesives for automobiles protection were prepared by emulsion polymerization. Monomers used were n-butyl acrylate(BA), acrylonitrile (AN), butyl methacrylate(BMA), glycidyl methacrylate(GMA), and acrylic acid (AA). Emulsifiers used were sodium lauryl sulfate and polyoxyethylene lauryl ether, which are an anionic emulsifier and a nonionic emulsifier respectively. Potassium persulfate was used as an initiator and polyvinyl alcohol was used as a stabilizer. Emulsion polymerization was carried out in a semi-batch reactor at $70^{\circ}C$ and agitation speed was kept at 200 rpm. Water resistance, heat resistance, acid resistance, alkali resistance and smoke resistance were examined. As a result, when each 0.03 mole of GMA and AA was introduced, the adhesion properties and various above mentioned resistances of the prepared adhesives were satisfied the standard for automobiles.

해안매립지 하수처리시설물에 적용한 저발열시멘트 콘크리트의 내화학성 평가 (Chemical Resistance of Low Heat Cement Concrete Used in Wastewater Treatment Structures Built on Reclaimed Land)

  • 정용택;이병재;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.113-119
    • /
    • 2019
  • 해안매립지에 건설되는 구조물은 해수로부터 유입되는 염소 및 황산염 이온 등의 화학적 침식에 의한 영향을 복합적으로 받는다. 염해는 콘크리트 내부의 철근을 부식시켜 구조물의 성능을 저하시킨다. 또한, 하수처리시설에서는 내부에서 발생되는 황산염에 의해 콘크리트가 열화되는 문제점을 가진다. 따라서 본 연구에서는 해안매립지에 건설되는 하수처리구조물에 적용할 수 있는 혼합형 저발열시멘트의 특성 및 내화학성을 평가하였다. 실험결과, 모든 배합조건에서 목표슬럼프 및 공기량을 모두 만족하였다. 동일 배합조건에서 LHC사용시 OPC 보다 슬럼프는 증가되고, 공기량은 감소하는 경향을 나타내었다. 압축강도 시험결과, 초기재령에서는 OPC의 강도발현이 빨랐으며, 28일 이후 LHC가 OPC보다 높은 강도를 나타내었다. 염소이온침투저항성 평가결과, LHC-B의 경우 56일 재령에서, "매우낮음" 단계의 염소이온침투저항성을 나타내 LHC의 내염해성을 확인하였다. 내화학성 평가 결과, 에폭시 처리 하지 않은 경우 LHC를 적용한 경우, OPC보다 약 18%정도 내화학성이 개선되는 것으로 나타났으며, 콘크리트 표면에 에폭시 공법 적용시 강도보존율이 95% 이상 확보 가능한 것으로 확인되었다.

알칼리 활성화 슬래그 시멘트 모르타르의 내황산성 (Resistance of Alkali Activated Slag Cement Mortar to Sulfuric Acid Attack)

  • 민경산;이승헌
    • 한국세라믹학회지
    • /
    • 제44권11호
    • /
    • pp.633-638
    • /
    • 2007
  • The setting time of alkali activated slag cement tends to be much faster than ordinary Portland cement, and its compressive strength had been higher from the 1 day but became lower than that of the cement on the 28 days. According to the results of the surface observation, weight loss, compressed strength, and erosion depth tests on the sulphuric acid solution. It has been drawn that alkali activated slag cement has a higher sulphate resistance than ordinary Portland cement, and in particular, the alkali activated slag cement added 5 wt% alumina cement has little deterioration on the sulphuric acid solution. The reason why the alkali activated slag cement has higher sulphate resistance than other hardened cement pastes is that it has no $Ca(OH)_2$ reactive to sulphate ion, and there is little $CaSO_4{\cdot}2H_2O$ production causing volume expansion, unlike other pastes. And it is supposed that $Al(OH)_3$ hydrates with high sulphate resistance, which is produced by adding the alumina cement increases the sulfate resistance.

감자 흑각병원균 Erwinia carotovora subsp. atroseptica의 화학적 방제 (Chemical control of potato Blackleg disease caused by Erwinia carotovora subsp. atroseptica in Korea)

  • 유용만;;배후남;김성문;임춘근;허장현
    • 농약과학회지
    • /
    • 제7권1호
    • /
    • pp.12-17
    • /
    • 2003
  • 감자 생산에 치명적인 흑각병을 유발하는 흑각병원균 (Erwinia carotovora subsp. atroseptica) 을 방제할 수 있는 화학적 방제제를 선발하기 위하여 7 종의 항생제와 oxolinic acid, 그리고 4 종의 구리제를 대상으로 병원균에 대한 억제효과와 저항성을 in vitro에서 조사하였다. Streptomycin, streptomycin sulfate, oxolinic acid는 0.02 mM 처리 24 시간 후, 그리고 구리제인 copper hydroxide, copper oxide, copper sulfate 는 3 mM 처리 24 시간 후 완전히 억제되었다. 약제들에 대한 병원균의 저항성을 조사하고자 최소 억제농도의 1.3 배를 처리하고 72 시간 후에 생존율을 조사한 결과, 항생제 및 oxolinic acid 처리구에서는 저항성균이 관찰되었으나, 구리제 처리구에서는 관찰되지 않았다. 저농도 처리로 병원균을 방제할 수 있는 2 종의 항생제 및 oxolinic acid 와 저항성균 유발 가능성이 낮은 구리제 3 종을 혼합처리였을 경우, streptomycin + copper oxide(0.016 + 1.2 mM, 9.3 + 171.6 ppm), streptomycin + copper hydroxide(0.016 + 1.5 mM, 9.3 + 146.3 ppm), streptomycin sulfate+copper oxide(0.005 + 1.2 mM, 7.0 + 171.6 ppm), streptomycin sulfate+copper hydroxide(0.005 + 1.5 mM, 7.0+146.3 ppm) 처리 24 시간 후 병원균의 생장은 완전 억제되었고, 72 시간 후 저항성균이 전혀 관찰되지 않았다. 그러나 oxolinic acid+구리제 혼합처리의 경우와 2 종의 항생제 및 oxolinic acid + copper sulfate 혼합처리의 경우 공히 균생장 억제효과가 나타나지 않았다. 본 실험의 결과는 효과적인 감자흑각병의 방제를 위하여 약제의 단일 사용보다는 혼합 사용하는 경우 더 높은 방제효과와 낮은 저항성균 유발효과가 있다는 것 을 보여주고 있다.

장내 세균의 약제내성 - 제1보 대장균의 Nalidixic Acid 및 기타 항균제에 대한 내성 (Resistance of Enterobacterianceae to antibacterial drugs I. Resistance of Eseherichia coli to nalidixic acid and six other antibacterial agents)

  • 하대유
    • 대한미생물학회지
    • /
    • 제5권1호
    • /
    • pp.27-31
    • /
    • 1970
  • Nalidixic acid and six other drugs were studied for in vitro effectiveness against 200 strains of Escherichia coli isolated recently from healthy persons and bactericidal activity of ampicillin against one respective strain of Escherichia coli and Salmonella typhi isolated were also studied. The resutlts obtained by the plate dilution method showed the following percentage of resistance: kanamycin, 2.5%; streptomycin, 12.0%; ampicillin, 13.5%; tetracyclin, 15.5%; chloramphenicol, 17.5%; colistin sulfate, 19.5%. No strains were resistant to nalidixic acid, clearly indicating that nalidixic acid is the most effective drug tested. Ampicillin, measured by test-tube diltion method, was highly bactericidal against Salmonella typhi at the concentration of 2.5mcg/ml and against Escherichia coli at 5mcg/ml.

  • PDF