• Title/Summary/Keyword: suggested temperature

Search Result 2,710, Processing Time 0.038 seconds

Preferred and Suggested Winter Indoor Temperatures of College Students (남녀 대학생의 겨울철 실내 쾌적온도 및 적정온도)

  • Shim, Huen-Sup;Jeong, Woon-Seon
    • The Korean Journal of Community Living Science
    • /
    • v.22 no.3
    • /
    • pp.485-491
    • /
    • 2011
  • This study was to present the preferred and the suggested indoor temperature of college students in winter based on their body composition. A total of 14 subjects(6 males and 8 females) participated in this study. They sat in a climatic chamber controlled at $24^{\circ}C$ wearing experimental garments(0.7clo). The air temperature decreased $1^{\circ}C$ every 15 minutes until it reached $19^{\circ}C$. After the stepwise temperature change, subjects were asked to select a comfortable air temperature by dialing the temperature control switch inside the chamber. The preferred temperature was determined when subjects did not change the air temperature for 10 minutes. The measurements were oxygen consumption, rectal temperature, skin temperature, and subjective sensation. Main results are as follows. In a mild cold condition, females demonstrated lower oxygen consumption and mean skin temperature than males while keeping a constant rectal temperature. Females increased rectal temperature and decreased mean skin temperature greater than males from $24^{\circ}C$ to $19^{\circ}C$. Males showed larger oxygen consumption increase than females. It appears that the thermo-physiological responses in a mild cold condition might be different between males and females. The preferred winter indoor temperature was $22.3^{\circ}C$ for males and $23.4^{\circ}C$ for females, and the suggested temperature was $21^{\circ}C$ for males and $23^{\circ}C$ for females.

Strip Tension Control Considering the Temperature Change in Multi-Span Systems

  • Lee Chang Woo;Shin Kee Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.958-967
    • /
    • 2005
  • The mathematical model for tension behaviors of a moving web by Shin (2000) is extended to the tension model considering the thermal strain due to temperature variation in furnace. The extended model includes the terms that take into account the effect of the change of the Young's Modulus, the thermal coefficient, and the thermal strain on the variation of strip tension. Computer simulation study proved that the extended tension model could be used to analyze tension behaviors even when the strip goes through temperature variation. By using the extended tension model, a new tension control method is suggested in this paper. The key factors of suggested tension control method include that the thermal strain of strip could be compensated by using the velocity adjustment of the helper-rollers. The computer simulation was carried out to confirm the performance of the suggested tension control method. Simulation results show that the suggested tension control logic not only overcomes the problem of the traditional tension control logic, but also improves the performance of tension control in a furnace of the CAL (Continuous Annealing Line).

Dynamic Constitutive Equations of Auto-body Steel Sheets with the Variation of Temperature (II) - Flow Stress Constitutive Equation - (차체용 강판의 온도에 따른 동적 구성방정식에 관한 연구 (II) - 온도에 따른 동적 구성방정식 -)

  • Lee, Hee-Jong;Song, Jung-Han;Park, Sung-Ho;Huh, Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.182-189
    • /
    • 2007
  • This paper is concerned with the empirical flow stress constitutive equation of steel sheets for an auto-body with the variation of temperature and strain rate. In order to represent the strain rate and temperature dependent behavior of the flow stress at the intermediate strain rates accurately, an empirical hardening equation is suggested by modifying the well-known Khan-Huang-Liang model. The temperature and strain rate dependent sensitivity of the flow stress at the intermediate strain rate is considered in the hardening equation by coupling the strain, the strain rate and the temperature. The hardening equation suggested gives good correlation with experimental results at various intermediate strain rates and temperatures. In order to verify the effectiveness and accuracy of the suggested model quantitatively, the standard deviation of the fitted result from the experimental one is compared with those of the other two well-known empirical constitutive models such as the Johnson-Cook and the Khan-Huang-Liang models. The comparison demonstrates that the suggested model gives relatively well description of experimental results at various strain rates and temperatures.

Temperature Monitoring System of Power MOSFET for IPCM (지능형 전력제어모듈을 위한 온도 모니터링 시스템)

  • Choi Nak-Gwon;Kim Ki-Hyun;Kim Hyoung-Woo;Seo Kil-Soo;Kim Nam-Kun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • We suggest a novel temperature detection method utilized in temperature monitoring system. Suggested method detects temperature variation by using $R_{ds(on)}$ characteristics of MOSFET, while conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. For voltage detection between drain and source, 10 bits resolution ADC is needed. Therefore possible measurement signal range is about ten mV. If detected temperature's voltage exceed protection temperature's voltage then controller generates OT (Over Temperature) signal to stop MOSFET's trigger signal. Whole process of measurement is controlled by software. Experimental results show that the developed temperature monitoring system can provide the suitable temperature monitoring method and difference between detected and data sheet value of the suggested system is about $3\%$.

Development of Ultrasonic Magnetostrictive Sensors System to Measure in Very High Temperatures (초고온 온도 측정을 위한 초음파 자왜 센서 시스템 개발)

  • 구길모;김상백;박치승;최종호;고덕영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.66-74
    • /
    • 2001
  • The temperature measurement of yen high temperature core melt is of importance in LAVA (Lower-plenum Arrested Vessel Attack) experiment in which gap formation between core melt and the reactor lower head, and the effect of the gap on thermal behavior are to be measured. The delay time of ultrasonic wavelets due to high temperature is suggested. As a first stage, a molten material temperature was measured up to 2300℃. Also, the optimization design of the ultrasonic temperature sensor with persistence at the high temperature was suggested in this paper. And the utilization of the theory suggested in the reference〔1〕and the efficiency of the developed system are certified by performing experiments. This sensor welded magnetostrictive element and tungsten element will be able to measure a temperature range of 3000℃ hereafter.

  • PDF

A Study of Superheater Temperature Control on an Once Through Boiler in Thermal Power Plant (화력발전소 관류보일러의 과열기 온도제어에 관한 연구)

  • Lee, Jo-Hyun;Jeong, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2022-2027
    • /
    • 2009
  • An supercritical once through boiler system has been used in the korea standard-type thermal power plant. It is critical in boiler operation that superheater temperature should be controlled within the specified limit. In this paper, control logic scheme is suggested for superheater temperature in once through boiler. Finally the simulation result using process model based simulator shows the validity of suggested control logic.

Estimation of small pan evaporation using temperature data (기온자료를 이용한 소형증발접시 증발량 산정)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.1
    • /
    • pp.37-53
    • /
    • 2017
  • Pan evaporation has been used as an indirect method for the estimation of reservoir evaporation. Therefore, in this study, pan evaporation estimation equations using only temperature data were suggested in the case that available meteorological data is limited. A formula for estimating the pan evaporation were suggested by comparing estimated pan evaporation with measured pan evaporation in 12 study areas in Korea. The suggested pan evaporation equations were verified in 44 study areas by comparing not only with temperature-based equations but also with equations using other meteorological data (temperature, wind speed, relative humidity, and sunshine duration). The study results indicate that the suggested equations in this study provide much better pan evaporation estimates, compared with other temperature-based equations. Overall, the suggested equations provide appropriate pan evaporation estimates in most of 56 study areas. Therefore, the suggested equations using only temperature data in this study are considered appropriate for the estimation of pan evaporation in Korea especially in the case that available meteorological data is limited. In the future, using the air temperature and pan evaporation data measured at the reservoir, further research is needed to examine the applicability of suggested equations for the estimation of reservoir evaporation.

An Experimental Study on the Evaluation of Adiabatic Temperature Rise of Concrete (콘크리트의 단열온도 상승량의 정량화에 관한 실험적 연구)

  • 강석화;이용호;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.186-196
    • /
    • 1995
  • In this study, parameters such as unit cement weight and placing temperature which influence on temperature rise and temperature rise velocity are investigated through adiabatic tests for the domestic ordinary portland cement(0PC). Adiabatic temperature rise suggested by Korean Concrete Spec. are compared with that from this experimental results. As a result of this study, adiabatic temperature rise of OPC suggested spec. is overestimated. Also it is shown that 2-parameter equation suggested in the spec. overestimate heat evolution at early age and reasonable prediction of heat evolution can be obtained by using 3-parameter equation. Results of numerical analysis by using the input data from this test and the suggested values from spec. shows similar temperatures. However thermal stresses pridicted using input value from spec. may result 20% more than that from this test in case of externally restricted state.

A Study on Generating Process of Regional Balance Point Temperature for Heating Degree-days in Korea (국내 난방도일의 지역별 균형점온도 산정 과정에 관한 연구)

  • Park, So Min;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.482-495
    • /
    • 2017
  • Degree-days are practically used as a tool to estimate energy consumption for heating and cooling. Degree-days are calculated by summing differences of balance point temperature and outside temperature for the analyzed period. Determining balance point temperature is a key point in calculating accurate degree-days. However, ASHRAE standards are used for balance point temperature in Korea because balance point temperature considering climate conditions and building thermal performance is not proposed in Korea. This study proposes the process to generate balance point temperature for heating degree-days considering Korean climate and building conditions. Also, a new balance point temperature for three regions in Korea will be suggested in this study. Balance point temperature of Seoul is approximately $15.0^{\circ}C$, lower than the current standard of $18.3^{\circ}C$. Balance point temperature of Seoul considering climate conditions and building performance can be different from the ASHRAE suggested value ($18.3^{\circ}C$). Results revealed the current standard for balance point temperature should be changed considering climate and building conditions in Korea.

Measurement of Irrigation Water Temperature and Preventive Measure against Cold Watter Damage to Paddy Rice (벼의 냉수피해 감소를 위한 관개수온 조사와 대책수립)

  • 정상옥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.52-59
    • /
    • 1999
  • Paddy rice is semi-tropical crop and requires warmirrigation water. If mean water temperature at the water source during the growing period is below 18$^{\circ}C$, sime kinds of water warming mechanism should be taken. In this study irrigation water temperature is measured and preventive measures to cold water damage on paddy rice are suggested. Field observations were performed at 100ha field area downtream of the Unmoon reservoir during the growing season of 1997. Land use, canal system, water temperature at irrigation canals. reservoir, and paddy fields were observed. In addition, growth and yield of the rice at selected plots were observed. Accordingly to the record, cold water damage occurred in this area due to the cold irrigation water supply in 1996. It did not occur because of the effective irrigation water management practice in 1997. However, several preventive measures such as pontoon intake system, using existing weir and construting a new warming pond, are suggested to prevent cold water damage in the future. If a new warming pond is construted to raise irrigation water temperature by 2 $^{\circ}C$, a pond area of 2.94 ha is required.

  • PDF