• 제목/요약/키워드: sudden change

검색결과 550건 처리시간 0.022초

관로 연결부의 응력집중저감기법연구 (A Study on Stress Concentration Alleviation at Pipe Connections)

  • 정소영;한택희;한금호;강영종
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.289-292
    • /
    • 2007
  • Stress concentration have a effect on commission of structures and sometimes it cause the fracture of structures. Stress concentration is appeared where have a sudden section change like pipe connections. So stress concentration is a potent influence at pipe connentions. This paper make a study of pipe connections to alleviate stress concentration, and propose the stress concentration alleviation method that will make better efficient pipe system and will have a good effect on economic, social aspect.

  • PDF

비선형 적응제어를 이용한 전력계통 안정화 (Power system stabilization via adaptive feedback linearization)

  • 윤태웅;이도관
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1221-1224
    • /
    • 1996
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method is combined with an identification algorithm which estimates the effect of a fault.

  • PDF

자동차 발전기 전압변동에 따른 차량 신호 변화에 대한 실험적 연구 (Experimental Study of Vehicle Signal Change for Generator Voltage Variation)

  • 고광호
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.235-240
    • /
    • 2018
  • The generator of an automobile supplies electric voltage and current for various electric components. The supplied voltage can be changed by sudden variation of the electric load. The voltage was controlled by independent power supply in the study. The TPS and APS signal was changes as the voltage of the power supply. The ECU output voltage and OBD signal voltage was changed also as the variance of the power supply.

급격한 조명 변화에 강건한 동영상 대조비 개선 방법 (Robust Method of Video Contrast Enhancement for Sudden Illumination Changes)

  • 박진욱;문영식
    • 전자공학회논문지
    • /
    • 제52권11호
    • /
    • pp.55-65
    • /
    • 2015
  • 동영상 대조비 개선 과정에서 단일 영상을 위해 연구된 대조비 개선 방법들을 사용할 수 있지만, 동영상의 연속성이 고려되지 않으면 원본 동영상에 없는 깜박임을 야기할 수 있다. 또한 동영상의 연속성을 고려하는 경우, 깜박임은 억제할 수 있지만 연속성 때문에 조명의 급격한 변화할 때 불필요한 페이드인/아웃(fade-in/out) 현상이 발생하는 단점이 발생할 수 있다. 본 논문에서는 깜박임과 페이드인/아웃 현상 없이 동영상의 대조비를 개선하는 방법을 제안한다. 제안하는 방법은 Fast Gray-Level Grouping(FGLG)를 사용하여 각 프레임의 대조비를 개선하고, 깜박임을 억제하기 위해 Exponential smoothing 필터를 사용한다. 불필요한 페이드인/아웃 현상을 억제하기 위해서는 S형 함수로 Exponential smoothing 필터의 평활화 비율을 프레임 별로 적응적으로 계산하여 적용한다. 실험에서 제안하는 방법과 기존의 방법들은 6가지 측정 기준을 적용하여 성능을 비교 및 분석한다. 실험 결과, 제안하는 방법은 영상 형태 보존을 측정하는 MSSIM과 깜박임을 측정하는 Flickering score에서 정량적으로 가장 높은 결과를 보여주었으며, 시각적인 품질 비교를 통해 조명 변화에 따른 적응적인 개선을 정성적 결과로 입증하였다.

슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템 (An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor)

  • 이준환;이승환;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.15-17
    • /
    • 2007
  • The variable speed engine generator set is interested for an isolated power system due to reduced fuel consumption and less emission. However, because of sluggish dynamic behavior of the internal combustion engine the power quality would be degraded during the sudden load power surge, where the power required by the load is not available by the engine due to the reduced engine speed. An isolated power system based on variable speed engine with a super-capacitor bank improves dynamic characteristics under sudden load change, and power quality, fuel consumption, and pollutants can be reduced remarkably. Also, it is verified by the computer simulation that the inverter of 3phase-4leg is compatible to the isolated power system with unbalanced load. In this paper, the feasibility of the system has been verified based on a 26kw commercial diesel engine system.

  • PDF

농형유도 풍력발전기의 성능개선을 위한 에너지저장장치의 동작특성 분석 (Operational Analysis of Energy Storage System to Improve Performance of Wind Power System with Induction Generator)

  • 이지헌;심명보;이혜연;한병문;양승철
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1138-1145
    • /
    • 2009
  • This paper presents an active and reactive power compensator for the wind power system with squirrel-cage induction generator. The output power of a wind power system changes irregularly according to the variation of wind speed. The developed system is able to continuously compensate the active and reactive power. The 3-phase inverter operates for the compensation of reactive power, while the DC/DC converter with super-capacitors operates for the compensation of active power. The operational feasibility of the proposed model was verified by simulations with PSCAD/EMTDC and the feasibility of hardware implementation was confirmed by experimental works with a scaled hardware model. The proposed compensator can be expected that developed system may be used to compensated the abrupt power variation due to sudden change of wind speed or sudden power-drop by tower effect. It can be also applied for the distributed generation and the Micro-Grid.

Chondrosarcoma Apoplexy in Thoracic Spine

  • Kim, Sang Woo;Kim, Min Su;Jung, Young Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권1호
    • /
    • pp.46-48
    • /
    • 2013
  • Chondrosarcoma is a very uncommon malignant primary bone tumor, especially, it occurs extremely rare in the spine. A 52-year-old man was admitted to the emergency room with sudden paraplegia. Twelve hours prior to a paraplegic event, he visited an outpatient clinic with discomfort and tenderness around the medial border of the right scapular, and his neurologic status was absolutely intact. Magnetic resonance imaging showed a lobulated soft tissue mass from T3 to T5, which extended to the epidural space. Computed tomography scans showed soft tissue mass on the spinal posterior arch and osteolytic change of the adjacent bony structures. Emergent surgery was performed and the lesion was removed. Dark reddish blood and gel-like material were encountered around the dura and posterior arch during the operation. Multiple pulmonary nodules were found on a chest CT scan and a biopsy of one of them had been proven to be a metastasis of chondrosarcoma. The histologic examination showed dedifferentiated chondrosarcoma. The patient's neurologic deficit was improved slowly from ASIA A to ASIA D. Chondrosarcoma in the spine is extremely rare, even more with acute hemorrhage and sudden expansion into the epidural space. We named it chondrosarcoma apoplexy. We should consider the possibility of a hemorrhagic event when the patient's neurologic deficit worsens suddenly with spinal bone tumor.

AA-GWR Water Retention Meter를 이용한 부동화 농도 측정법

  • 최창학
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 춘계학술발표논문집
    • /
    • pp.80-92
    • /
    • 2003
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids(IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the mean of the solids differences is 0.36% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

  • PDF

Structure and Source of Low Salinity Water Observed During May in the Cheju Strait

  • Byun, Sang-Kyung
    • Journal of the korean society of oceanography
    • /
    • 제35권4호
    • /
    • pp.170-178
    • /
    • 2000
  • Low salinity water was observed during May in the Cheju Strait. Its structure and source were studied by using both the hydrographic data collected not only in the Cheju Strait during 1987-1989 but also in the wider area around Cheju Island extending to the Bank of Changjiang river in 1994 and the current data taken in the Strait during 1987-1989. The water had lower values of temperature, salinity, and density compared with the surrounding water and it was found in the surface layer outside of Tsushima Current Water 10-50 km off Cheju coast. The density of low salinity water was more dependent on salinity than on temperature. The low salinity water flowed into the Strait from the west as a series of intermittent waters whose size was variable in width and in thickness. The low salinity water was originated from the Chanajiang River Diluted Water. In the Cheju Strait, the water showed changes within 3 days on time and 30-50 km on space, and its sudden appearance was marked especially in May. Such strong variability and sudden appearance may be attributed to the beginning stage in May when the fresh water of Changjiang River Diluted Water starts to arrive in the Cheju Strait.

  • PDF

FESWMS-2DH를 이용한 하천의 흐름 해석 (Flow Analysis of Rivers by using FESWMS-2DH)

  • 이철응;심재욱;박동헌
    • 산업기술연구
    • /
    • 제29권A호
    • /
    • pp.111-122
    • /
    • 2009
  • In this study, flood stage was computed by HEC-RAS, 1-D numerical analysis model and FESWMS-2DH, 2-D numerical model. Flood stages computed by two different models were compared for straight line, dot axle watercourse, dead-zone watercourse, section sudden-changing watercourse, and curved watercourse. From the results, flow velocity and water level were similar in straight watercourse and dot-reduction watercourse. However, there was difference of flow velocity and water level in dead-zone watercourse, sudden expansion, dot-reduction, and curve-watercourse. This result might be influenced by rapid change of watercourse due to dead-zone, the angle of inflow and outflow, and the curvature. Especially in this study, numerical model was applied to Wol-Song-Cheon at Chuncheon in order to analyze the effect of flood stage by two different models. By flowing properties around the bridge and confluence of rivers, it was found that flow velocity and water level was changed. Therefore, it was concluded that a lot of uncertainties are contained in the present bank.

  • PDF