• Title/Summary/Keyword: suction pump

Search Result 209, Processing Time 0.023 seconds

Suction Detection in Left Ventricular Assist System: Data Fusion Approach

  • Park, Seongjin
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.3
    • /
    • pp.368-375
    • /
    • 2003
  • Data fusion approach is investigated to avoid suction in the left ventricular assist system (LVAS) using a nonpulsatile pump. LVAS requires careful control of pump speed to support the heart while preventing suction in the left ventricle and providing proper cardiac output at adequate perfusion pressure to the body. Since the implanted sensors are usually unreliable for long-term use, a sensorless approach is adopted to detect suction. The pump model is developed to provide the load coefficient as a necessary signal to the data fusion system without the implanted sensors. The load coefficient of the pump mimics the pulsatility property of the actual pump flow and provides more comparable information than the pump flow after suction occurs. Four signals are generated from the load coefficient as inputs to the data fusion system for suction detection and a neural fuzzy method is implemented to construct the data fusion system. The data fusion approach has a good ability to classify suction status and it can also be used to design a controller for LVAS.

Improvement of Pump Performance and Suction Performance of a Very Low Specific Speed Centrifugal Pump (극저비속도 원심펌프의 펌프성능 및 흡입성능 향상)

  • Choi Young-Do;Kurokawa Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.29-35
    • /
    • 2006
  • There are high expectations of improving the performance of a centrifugal pump in the range of very low specific speed which has been developed recently for the use instead of a conventional positive displacement pump. However, even though elaborated studies has been done for the pump intensively, the pump performance has not increased so much. Also, it is difficult to find detailed information from published literatures for suction performance of the very low specific speed centrifugal pump. Therefore, this study is aimed to improve the pump performance more and to make clear suction performance of the very low specific speed centrifugal pump. Recircular flow stopper is installed on the pump casing wall at the region of impeller outlet to improve the pump performance and J-Groove is also installed at the inlet of the pump casing for the purpose of suppressing occurrence of cavitation as well as improving pump performance. The result suggests that the simultaneous improvement of pump performance and suction performance of the very low specific speed centrifugal pump is possible by adopting optimum configuration of the recirculation flow stopper and J-Groove.

Effects of Inducer Tip Clearance on the Suction Performance of a Pump for Turbopumps (인듀서 익단간극이 터보펌프용 펌프의 흡입성능에 미치는 영향)

  • Choi, Chang-Ho;Kim, Dae-Jin;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.41-45
    • /
    • 2012
  • The effects of inducer tip clearance on the suction performance of a pump for turbopumps are investigated. Experiments for the pump with inducer tip clearances of 1.8% and 1.4% of blade height were performed. The experimental results showed that the suction performance of the pump increased as the tip clearance decreased. It seems that the suction performance of the pump becomes better with smaller tip clearances because the strength of the inducer backflow becomes weak with the decreased tip clearance.

Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method (퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출)

  • Park, Seung-Kyu;Choi, Seong-Jin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.500-506
    • /
    • 2012
  • A method to model left ventricular assist device (LVAD) and detect suction occurrence for safe LVAD operation is presented. An axial flow blood pump as a LVAD has been used to assist patient with heart problems. While an axial flow blood pump, a kind of a non-pulsatile pump, has relative advantages of small size and efficiency compared to pulsatile devices, it has a difficulty in determining a safe pump operating condition. It can show different pump operating statuses such as a normal status and a suction status whether suction occurs in left ventricle or not. A fuzzy subtractive clustering method is used to determine a model of the axial flow blood pump with this pump operating characteristic and the developed pump model can provide blood flow estimates before and after suction occurrence in left ventricle. Also, a fuzzy subtractive clustering method is utilized to develop a suction detection model which can identify whether suction occurs in left ventricle or not.

A numerical study on the suction performance of a submerged cargo pump (수중 카고 펌프의 흡입성능에 관한 수치해석적 연구)

  • Kim, Joon-Hyung;Choi, Young-Seok;Lee, Kyoung-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.18-23
    • /
    • 2008
  • In this paper, effects of inlet shape on the performance of a submerged cargo pump were numerically studied using a commercial CFD code ANSYS-CFX. The inlet shape, especially the gap between pump and suction well, is an important parameter in a point of view of performances of submerged cargo pump due to its effects on the residual and also hydraulic performance of the pump, respectively. To investigate the optimized gap, the overall performance degradations were calculated with the gap. In addition to that, the flow field through the gap was investigated to explain the effect of velocity non-uniformity on the performance of the pump impeller.

Numerical analysis of flow characteristic in double suction pump (양흡입 펌프 내부 유동특성에 관한 수치적 연구)

  • Kim, S.-J.;Kim, D.-W.;Kim, Yon J,
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.257-263
    • /
    • 1999
  • The flow characteristics of double suction pump are investigated by numerically Calculations are performed by using SIMPLE algorithm at the design and off-design points. Symmetric nature of flow fields in blade channels is discovered at design point, but asymmetirc effects are discovered at the off-design point. Numerical results show that the formation of secondary flow in volute of double suction pump shows different trends when compared with the case of single suction pump. Also results show that double vortices are formed in the volute cross section.

  • PDF

Vortex Cavitation from Baffle Plate and Pump Vibration in a Double-Suction Volute Pump

  • Sato, Toshiyuki;Nagahara, Takahide;Tanaka, Kazuhiro;Fuchiwaki, Masaki;Shimizu, Fumio;Inoue, Akira
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.76-83
    • /
    • 2011
  • This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in a double-suction volute pump and pump oscillation which causes cavitation noise from the pump. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

The effect of suction pipe leaning angle on the internal flow of pump sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.849-855
    • /
    • 2015
  • A better flow condition for the intake of pump is provided by the sump pump that connects the forebay to the intake of the pump station. If the suction sump is improperly shaped or sized, air-entraining vortices or submerged vortices may develop. These phenomena may greatly affect pump operation if vortices become sufficiently large. Moreover, any remaining vortices in the pump flow passage may result in an increase in the noise and vibration of the pump. Therefore, the vortices in the pump flow passage must be reduced to achieve good pump sump station performance. In this study, the effect of suction pipe leaning angle on the pump sump's internal flow is investigated. Additionally, a pipe type with an elbow shape is investigated. The results show that the air entraining vortices occur under the condition of a water level ratio H/D = 1.31 for each suction pipe type.

Microfluidic Suction Pump based on Restoring Force of Elastomer for Liquid Transportation in Microfluidic System (미세유체시스템의 유체이송을 위한 탄성체의 복원력을 이용한 흡입형 미세유체펌프)

  • Byun, Kang Il;Han, Eui Don;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • This paper presents a disposable passive suction pump that uses the restoring force of an elastomeric chamber for liquid transportation in a microfluidic system. The proposed suction pump can be operated by finger pressure without any peripheral equipment. To adjust the generated suction pressure, five different displacements of the suction chamber ceiling, two different chamber shapes, and five different elastic moduli of the elastomer were considered. For a cylindrical chamber with a 5 mm height and 5 mm radius, the generated suction pressure and flow rate increased almost linearly up to about 31 kPa and $160.8{\mu}L/min$, respectively, depending on the chamber deformation. A maximum suction pressure of $42.9{\pm}0.7kPa$ was obtained for a hemispherical chamber with a 2.1 mm height and 5 mm radius.

A Study of Impeller-Casing Interactions in a Centrifugal Pump (원심펌프 임펠러와 케이싱 사이의 상호 작용에 대한 연구)

  • Chung Kyung-Nam;Park Pyun-Gu
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.585-588
    • /
    • 2002
  • Pump casing has blockage effects on Impeller flow in a centrifugal pump such that the flow field around volute tongue has quite large change when the impeller rotates. A double suction pump is widely used in industrial world because it has lower NPSH required than a single suction pump. Thus, in this study, the interaction between impeller and volute casing has been investigated by using CFD for a double-suction centrifugal pump. Quasi-steady method and full pump model has been employed for the numerical calculation.

  • PDF