• Title/Summary/Keyword: suction detection

Search Result 22, Processing Time 0.03 seconds

Suction Detection in Left Ventricular Assist System: Data Fusion Approach

  • Park, Seongjin
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.3
    • /
    • pp.368-375
    • /
    • 2003
  • Data fusion approach is investigated to avoid suction in the left ventricular assist system (LVAS) using a nonpulsatile pump. LVAS requires careful control of pump speed to support the heart while preventing suction in the left ventricle and providing proper cardiac output at adequate perfusion pressure to the body. Since the implanted sensors are usually unreliable for long-term use, a sensorless approach is adopted to detect suction. The pump model is developed to provide the load coefficient as a necessary signal to the data fusion system without the implanted sensors. The load coefficient of the pump mimics the pulsatility property of the actual pump flow and provides more comparable information than the pump flow after suction occurs. Four signals are generated from the load coefficient as inputs to the data fusion system for suction detection and a neural fuzzy method is implemented to construct the data fusion system. The data fusion approach has a good ability to classify suction status and it can also be used to design a controller for LVAS.

Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method (퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출)

  • Park, Seung-Kyu;Choi, Seong-Jin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.500-506
    • /
    • 2012
  • A method to model left ventricular assist device (LVAD) and detect suction occurrence for safe LVAD operation is presented. An axial flow blood pump as a LVAD has been used to assist patient with heart problems. While an axial flow blood pump, a kind of a non-pulsatile pump, has relative advantages of small size and efficiency compared to pulsatile devices, it has a difficulty in determining a safe pump operating condition. It can show different pump operating statuses such as a normal status and a suction status whether suction occurs in left ventricle or not. A fuzzy subtractive clustering method is used to determine a model of the axial flow blood pump with this pump operating characteristic and the developed pump model can provide blood flow estimates before and after suction occurrence in left ventricle. Also, a fuzzy subtractive clustering method is utilized to develop a suction detection model which can identify whether suction occurs in left ventricle or not.

How Reliable Are Diagnostic Methods of Hirschsprung Disease? (히르슈슈프룽병의 진단법은 얼마나 신뢰할 만한가?)

  • Kim, Hanbaro;Kim, Dae Yeon;Kim, Seong Chul;Namgoong, Jung-Man;Hwang, Ji-Hee
    • Advances in pediatric surgery
    • /
    • v.20 no.2
    • /
    • pp.33-37
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the diagnostic accuracy of the non-invasive diagnostic methods and rectal suction biopsy for the detection of Hirschsprung disease (HD). Methods: We reviewed diagnostic methods and results retrospectively in patients who underwent anorectal manometry, barium enema and rectal suction biopsy for the diagnosis of HD at Asan Medical Center from January 2000 to December 2012. Results: There were 97 patients (59 neonates and 38 infants) in the study period. The overall accuracy of anorectal manometry for the diagnosis of HD was 71.1% and its sensitivity was 51.4% (48.1% in neonate and 62.5% in infant, respectively) and its overall specificity was 82.3% (81.3% in neonate and 83.3% in infant, respectively). The Overall accuracy of barium enema was 66.0% (72.8% in neonate and 55.3% in infant, respectively) and specificity of barium enema was 53.2% (56.3% in neonate and 50.0% in infant, respectively). These results were lower than those of anorectal manometry. The overall sensitivity of barium enema was 88.6% (92.6% in neonate and 75.0% in infant, respectively) and it was higher than the sensitivity of anorectal manometry. Histological studies confirmed HD in 35 patients, in one of whom the suction biopsy showed negative finding. Conclusion: Accuracy of non-invasive methods for diagnosis of HD in our study is lower than those in previous study, so we need to improve the quality of diagnostic tools in our hospital. We conclude that the rectal suction biopsy is the most accurate test for diagnosing HD, so the biopsy to confirm the diagnosis of the HD is very important.

Fault Detection and Diagnosis of the Deaerator Level Control System in Nuclear Power Plants

  • Kim Kyung Youn;Lee Yoon Joon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.73-82
    • /
    • 2004
  • The deaerator of a power plant is one of feedwater heaters in the secondary system, and it is located above the feedwater pumps. The feedwater pumps take the water from the deaerator storage tank, and the net positive suction head(NSPH) should always be ensured. To secure the sufficient NPSH, the deaerator tank is equipped with the level control system of which level sensors are critical items. And it is necessary to ascertain the sensor state on-line. For this, a model-based fault detection and diagnosis(FDD) is introduced in this study. The dynamic control model is formulated from the relation of input-output flow rates and liquid-level of the deaerator storage tank. Then an adaptive state estimator is designed for the fault detection and diagnosis of sensors. The performance and effectiveness of the proposed FDD scheme are evaluated by applying the operation data of Yonggwang Units 3 & 4.

Design of Cavitation-Resistive Pump Inducer (공동현상을 고려한 펌프 인듀서 설계)

  • Jung, Keun-Hwa;Ahn, Kwang-Woon;Lee, Seungbae;Kim, Jin-Hwa;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.185-190
    • /
    • 2001
  • The cavitation causes suction performance and efficiency of the high-speed pump to be reduced significantly To diminish these effects, the inducer has been used. Most of the inducer is designed at a maximum efficiency point of the pump, therefore suction performance drop due to effects of flow separation and inlet inverse flow is often observed at off-design point. The objective of this study is to find out the cavitation modes at various conditions by applying event detection technique and to design an inducer reducing cavitation. The pressure fluctuations at each cavitating condition were measured at inducer inlet and outlet locations using pressure transducers, which were located 90 degrees apart from each other to identify the cavitation modes. The time-frequency characteristics were analyzed by using Choi-williams distribution. In the second part of this paper, the inducer design method which uses nominal performance characteristic and onset condition of cavitation is introduced and applied to real situation.

  • PDF

Effect of Blade Tip Geometry on Heat Transfer Coefficients on Gas Turbine Blade Tips and Near Tip Regions (가스터빈 블레이드 끝단 형상에 따른 블레이드 끝단 및 그 주변에서의 열전달 계수 변화)

  • Kwak Jae-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.328-336
    • /
    • 2006
  • Detailed heat transfer coefficient distributions an two. types of gas turbine blade tip, plane tip and squealer tip, were measured using a hue-detection base transient liquid crystals technique.. The heat transfer coefficients an the shroud and near tip regions of the pressure and suction sides af the blade were also. measured. The heat transfer measurements were taken at the three different tip gap clearances af 1.0%, 1.5%, and 2.5% of blade span. Results shaw the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. By using squealer tip, however, the reductions af heat transfer coefficients near the tip regions of the pressure and suction sides were nat remarkable.

Heat Transfer Coefficients on a Gas Turbine Blade Tip and Near Tip Regions (가스 터빈 블레이드 팁과 그 주변에서의 열전달 계수)

  • Kwak, Jae-Su
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.430-435
    • /
    • 2003
  • Detailed heat transfer coefficient distributions on a gas turbine blade tip were measured using a hue-detection base transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Both plane tip and squealer tip blade were considered. The heat transfer measurements were taken at the three different tip gap clearance of 1.0%, 1.5%, and 2.5% of blade span. Results show the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. However, the reductions of heat transfer coefficients near the tip regions of the pressure and suction sides were not remarkable.

  • PDF

Analysis of Volatile Fatty Acids in Air by Dynamic SPME (Dynamic SPME를 이용한 공기 중 지방산 분석)

  • Yu, Mee-Seon;Yang, Sung-Bong;Ha, Nam-Ki
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

Technical and Commercialization Status of Urine and Feces Disposal Systems (자동배설처리기 기술 및 상품화 현황)

  • Koh, E.J.;Park, S.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.169-175
    • /
    • 2015
  • Urine and/or feces disposal systems are expected to replace the diapers currently used for urine and feces disposal for the elderly with urinal and/or fecal incontinence. The are designed to detect the urine and/or feces, cleanse the excremental body organs with water transported from a cleansing water container in the main body, suction them into a fluid waste storage container for future disposal, and dry the area with hot air supplied also from the main body. These systems thus could relieve the chores of a caregiver and could also enhance the patient's hygiene. We reviewed in this paper the detection systems of urine and feces, the main components of the urine and feces disposal systems, and tried to classify the systems currently available in the market.

  • PDF

Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps (소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.