• Title/Summary/Keyword: subway tunnel station

Search Result 71, Processing Time 0.028 seconds

Characteristics of Particulate Matter Concentration and Classification of Contamination Patterns in the Seoul Metropolitan Subway Tunnels (서울시 지하철 터널 내 입자상물질의 농도 특성 및 오염형태 분류)

  • Lee, Eun-Sun;Lee, Tae-Jung;Park, Min-Bin;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.593-604
    • /
    • 2017
  • The suspended particulate matter(PM) was measured in subway tunnel of Seoul Line 1 to 9 in order to evaluate the pollution degree and characteristics of the PM in the subway tunnel. Also, to analyze the effect of outdoor aerosol concentration on the PM concentration of subway tunnels, the ambient PM concentration around the subway station was extracted by spatial analysis using $PM_{10}$ data of Seoul air pollution monitoring network. Finally, in order to understand pollution pattern in the Seoul subway tunnels, cluster analysis was performed based on input data set such as PM levels in tunnel, tunnel depth, length, curvature radius, outdoor ambient air pollution levels and so on. The average concentration of $PM_{10}$, $PM_{2.5}$, and $PM_1$ on subway tunnels were $98.0{\pm}37.4$, $78.4{\pm}28.7$, and $56.9{\pm}19.2{\mu}g/m^3$, respectively. As a result of the cluster analysis, tunnels from Seoul subway Line-1 to Line-9 were classified into five classes, and the concentrations and physical properties of the tunnels were compared. This study can provide a method to reduce PM concentration in tunnel for each pollution pattern and provide basic information about air quality control in Seoul subway tunnel.

A study on safety evaluation by changing smoke ventilation mode in subway tunnels (지하철터널 환기변환모드에 따른 안전성 평가에 관한 연구)

  • Rie, Dong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.389-400
    • /
    • 2003
  • In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation (SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station. Fire Dynamic Simulation (FDS) is used the SES's velocity boundary conditions to clarity the smoke exhaust effectiveness by the variations with mechnical ventilation system. We compared each 6 types of smoke exhaust systems for the result of smoke density and temperature distributions for 1.5m height from the subway station base in order to clarify the safety evaluation for the heat and smoke exhaust on subway fire.

  • PDF

NLOS Propagation Characteristics in a Curved Subway Tunnel (지하철 곡선 터널에서의 NLOS 전파 특성)

  • 정회동;윤찬의;강영진;송문규
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.322-325
    • /
    • 2003
  • In this paper, path loss characteristics in a curved subway tunnel are measured and analyzed. The measurement is carried out in the frequency bands of 2.45GHz and 5.8GHz. A directional antenna is employed for transmission and an omnidirectional antenna for reception. This measurement is performed in the subway tunnel in the vicinity of the Daejon station. The tunnel is curved and its cross section is arch-shaped. The path loss is measured with the location of the transmitter antenna fixed and the receiver antenna moving in the tunnel. The measured path loss ratio is about 0.1dBm/m. Also, the signal received from the antenna located on the outer side of curve in the tunnel experiences weaker path loss.

  • PDF

A study on the development of thermal environment prediction program in tunnel of the subway (지하철 터널내 열환경 예측 프로그램 개발에 관한 연구)

  • Kim, J.R.;Kim, D.G.;Kum, J.S.;Choi, K.H.;Jeong, H.M.;Park, J.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.504-516
    • /
    • 1997
  • Recently scientists and engineers are developing a system to get waste heat of low-temperature level with advanced heat pump, which have not been used up to now. As the reason, it is necessary to examine capability of using waste heat which is raised up in the tunnel of subway out of widely distributed low-temperature waste heat in large cities. Therefore we surveyed thermal environment of the tunnel of subway in $S\check{o}my\check{o}n$, downtown of Pusan, from November 1995 to December 1996 and developed a program to predict the thermal environment of subway on the basis of experimental data and the geometries of tunnels. This paper has proved availability of waste heat of subway when the measured results obtained in subway in the winter time and the simulated results of thermal environment prediction program are compared, as well as has reported results of estimating reliability of the simulation program. As the result, the charateristics of thermal environment in the tunnel of subway in $S\check{o}my\check{o}n$ station in the winter time are to be followed; 1) temperature in the tunnel is about $10^{\circ}C$ higher than outside air temperature, 2) temperature change in the tunnel is less than that in the platform so that we may obtain stable heat source, 3) and when the measured results obtained in subway in the winter time and the simulated results of thermal environment prodiction program is compared, both results show similar tendency. Therefore, we confirm estimating reliability of the simulation program.

  • PDF

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway (5678 서울도시철도 지하역사의 라돈 관리 현황)

  • Kim, Jun-Hyun;Yoon, Hun-Sik;Seo, Kang-Jin;Woo, Hee-Yeong;Kim, Man-Hwa;Park, Jong-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

Fundamental study on enlargement method of existing subway tunnel during operation for sidetrack construction (부본선 건설을 위한 기존 지하철 터널의 운영 중 확폭 방안에 대한 기초연구)

  • Lee, Hyobum;Koh, Sung-Yil;Jun, Jonghun;Yoon, Hee Taek;Yi, Na Hyun;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.59-76
    • /
    • 2020
  • As a continuous increase in demand for the transportation infrastructure in the metropolitan area, the renovation of existing metropolitan and urban railway lines for the rapid transport system requires the construction of sidetrack that can operate local and express trains simultaneously. However, the construction of sidetrack after stopping the operation of the existing subway line causes a lot of economic losses, therefore it is essential to study the tunnel enlargement scheme during the operation of the existing subway tunnel. Accordingly, in this paper, basic research on the enlargement plan of the existing subway tunnel was carried out for the renovation of the existing subway line. In order to investigate the method for the sidetrack construction, the Government Complex Gwacheon station on the Gwacheon line of subway line 4 was selected as a virtual research station. Subsequently, four construction plans including tunnel cross-sectional plan for each section were reviewed and constructability and economic feasibility were compared. Finally, the stability assessment was conducted for the selected construction plan which was considered to be relatively unstable by 3-D full numerical analysis considering the sidetrack construction process.

Train Wind Analysis of Subway Platforms (지하철 승강장 열차풍 특성 분석)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun;Kim, Shin-Do;Lee, Kyoung-Bin;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.100-106
    • /
    • 2011
  • PSD(platform screen door) was completely installed at all of Seoul subway station(line 1~8) using 640million people per day by 2010. After installation of PSD, the influence of train induced wind at platform decreased, but is estimated to increase in subway tunnel. In this paper, train induced wind occurred by pass of subway at platform was measured and analyzed using numerical analysis by computational fluid dynamics.

  • PDF