• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.029 seconds

Numerical Study on the characteristics of fire driven flow for smoke ventilation system operating in the deeply underground subway station (대심도 지하역사에서의 화재시 급 배기 동작유무에 따른 열 연기 거동 분석)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.66-72
    • /
    • 2008
  • In this study, transient 3D numerical simulations were performed to analyze the characteristics of fire driven flow for smoke ventilation system operating conditions in the deeply underground subway station. The smoke flow patterns were compared and discussed under smoke fan operating mode and off mode in the platform. Soongsil Univ. station(line number 7)was chosen for simulation which was the one of the deepest underground subway stations in the each lines of Seoul. The geometry for model is 365m in length include railway, 23.5m for width, 47m for depth. Therefore 10,000,000 structured grids were used for fire simulation. The parallel computational method for fast calculation was employed to compute the heat and mass transfer eqn's with 6 CPUs(Intel 3.0GHz Dual CPU, 12Cores) of the linux clustering machine. The fire driven flow was simulated with using FDS code in which LES method was applied. The Heat release rate was 10MW and The Ultrafast model was applied for the growing model of the fire source.

  • PDF

A study on the Design of a u-railroad Disaster Prevention System for Urban Disaster Prevention Management (도시 재난 관리를 위한 u-철도 방재시스템 설계에 관한 연구)

  • Ham, Eun-Gu;Roh, Sam-Kew
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.72-80
    • /
    • 2010
  • This study suggests ubiquitous railway disaster prevention system that gearing Ubiquitous Sensor Network system information take to the subway fire accident information which emergency response procedure as occurring subway fire accident scenario. Also it is proposed that emergency response system though fire scenario. collected Information was analyzed each system over providing information and it is designed to exchanging information structure though relation system. The ubiquitous railway disaster prevention system basically consists by four unit stages as prevention, preparedness, response and recovery system. Especially, in this system can supply real time accident information to the relevant government offices and public through forecasting and warning system by utilizing recognition of the five senses in case of accident. also, it is build that to make decisions as linking 2-dimension and 3-dimension space information interface of ubiquitous sensor networks and expected scenarios.

Gateless System in the Subway station (전철역에서의 Gateless 시스템)

  • Lee, Yong-Jea;Kim, Do-Hun;Lee, Kyo-Sung;Oh, Se-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1211-1213
    • /
    • 2002
  • We have frequently felt it inconvenient to collect fare drawing the card in transportation system. Especially, for subway the fares of mass transportation at rush hours of the days, it's important to find a way to collect fares without unnecessarily delaying passengers. In this paper, we proposed a system for the gateless fare collection passing through the booth in only carrying the card. In this system that RF-ID system and Bluetooth are applied. We designed two wireless communication channels. One is the 125kHz communication channel by FSK and PSK for power supplying on the card and identification and the other is 2.4GHz channel for the collection.

  • PDF

A Conceptual Study on Disaster Detection and Response System (재난전조 감지 및 재난대응 시스템에 관한 개념연구)

  • Park, Mi-yun;Koo, Won-yong;Park, Wan-soon;Kwon, Se-gon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • If a disaster occurs in the underground like subway, disaster response system should minimize the casualties. It must quickly guide passengers to a safe evacuation route. But sometimes the system does not work properly. And then they need distributed disaster response system which make decision autonomously. We perform conceptual research about distributed autonomous decision-making disaster detection and response system and disaster detection method.

Recent Trends in the Intelligent Surveillance Technologies (도시철도 지능형 감시시스템에 대한 국외기술 동향 분석)

  • An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.630-635
    • /
    • 2008
  • An urban transit is representative public transportation which lots of people take everyday. Especially, the station of urban transit is one of the very important public civil infrastructures. From the teachings of subway fire disaster occurred at Daegu on 2003, a certain incident might create large numbers of deaths or injuries and a lot of damages to the subway station without having an accurate grasp of emergency situation and doing proper action on the situation. Therefore, the passive surveillance system, which means the present CCTV based system, needs to be changed into the active one. The active surveillance system is the CCTV based system with intelligent softwares which affords to prevent a certain incident or trouble and its aggravation. In this paper, the state of the art of the representative companies developing intelligent softwares and its application sites of Australia and Hong Kong are briefly introduced. Finally, with the consideration of its recent trends, some technical contents for the intelligent surveillance system of domestic urban transit are briefly described.

  • PDF

Current Status on Seismic Design/Evaluation of Metropolitan Rapid Transit System (도시철도 구조물의 내진설계 및 평가 현황조사)

  • Kim, Jong-Min;Kim, Jin-Ho;Lim, Nam-Hyoung;Kang, Young-Jong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.220-223
    • /
    • 2008
  • Many structural engineers believed that RC underground structures like subway system might not be seriously damaged during earthquakes, until the Great Hanshin earthquake(a.k.a Kobe earthquake). But there is only one domestic seismic code of rapid transit system that established by Ministry of Construction & Transportation in 2005. Therefore, to investigate of current status on seismic design and evaluation method of rapid transit system is essential to estimate seismic performance of subway structural systems. In this study, comparing domestic codes and seismic evaluation methods with foreign system is performed.

  • PDF

Insulation Design of the Induction Motor for Subway Traction (전동차 견인용 유도전동기 절연 설계)

  • Lee, J.I.;Lee, J.I.;Kim, K.C.;Lee, K.J.;Kim, J.H.;Choi, Y.C.;Park, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.333-335
    • /
    • 1999
  • In this paper, the insulation system of induction motor for subway traction was designed. In order to design the insulation system of induction motor, various types of insulation system were compared, at first, and test method was investigated in order to verify the designed insulation system. The designed insulation system was satisfied economically, technically by experimental test.

  • PDF

A Study On Card Discrimination of Gateless Fare Collection System in the Subway (지하철 무개찰 시스템에서의 카드 판별에 관한 연구)

  • Kim, Hyun;Park, Jung-Gyun;Ryu, Hyoung-Sun;Choi, Hyun-Young;Kim, Si-Ku;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2461-2463
    • /
    • 2001
  • In this paper, we propose gateless fare collection system in the subway, which is removed the gate and it's critical to find a way to collect fares without unnecessarily delaying passengers. The gateless fare collection system consists of data communication zone and card check zone. Card's checking zone system may extract fare from two or more cards that one person carries. In this system, the multiple carrier frequencies of 125KHz and 2.45GHz are adopted.

  • PDF

The study of Safety education, safe experience for students to develop research simulreyiteo (안전체험 시뮬레이터 개발에 관한 연구)

  • Kim, Tae-hwan
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.1
    • /
    • pp.46-59
    • /
    • 2010
  • In this study, the safety training of comparative analysis of the realities of Korea's safety training and international experience and practical training for the safety experience of a virtual reality simulator, the development of safe conduct as a controlled motion simulator system, image H / W and the control system works, sound effects H / W and the control system works, 4D special effects (smoke, heat, wind, vibration) and a control system integration, mission control system for the selection and evaluation of the proposal, and safety training on Game S / W of development as we have never experienced an earthquake action plan and evacuate to escape the power of experience and the experience of an earthquake (vibration + video), Also the collapse and a fire escape on the experience of following second disaster, the building collapsed during an escape experience in the field, in case of fire According to the initial fire suppression and fire extinguisher usage experience - experience of smoke and heat to escape in, Moreover, the Daegu subway fire in public places such as subway and evacuated to escape the experience, considering the suggested Simulator.

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.