• 제목/요약/키워드: subway system

검색결과 859건 처리시간 0.044초

전동차내 폼알데하이드 저감방안에 관한 연구 (A research to decrease Formaldehyde on the train)

  • 최성호;최순기;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1009-1013
    • /
    • 2011
  • Seoul Metro Line 1 to 4 guests per day to 4.5 million people have been using the subway. This is close to the city population, 57 percent of people use the subway and found that 57 percent of people use the subway and found that this is close to the city population. Motor vehicle indoor air quality, especially of the major factors affecting is passenger's clothing, cosmetics, adhesives and formaldehyde by the action and so are able to keep. Enclosure 30ppm formaldehyde during prolonged exposure at concentrations above the nose, bronchial cough and a burning can cause symptoms. It is necessary to introduce an appropriate ventilation system. 1-4 Line Press in 2008, leaving the subway, and normally the train measured in room air quality. Measurements in 2005, $19.3{\sim}83{\mu}g/m^3$, 2008 Year ND ~ $61.7{\mu}g/m^3$ is. When congestion(rush hour) to temporarily increase the formaldehyde can result in a higher number. Automatic detection of formaldehyde and improve ventilation to a practical system, and it is necessary to chatneun. In research since 2006, Removal of formaldehyde were analyzed for the study. the passengers on the effects of formaldehyde in rush hour, the plan for increasing the ventilation through the analysis of various factors, such as electric vehicle practical ways to improve air quality have been studied.

  • PDF

지하철 재난 전조 예측 모델 개발 (Development of Predictive Models for Subway Disaster Forecasting)

  • 박미연;박완순;이정훈;권세곤
    • 한국방재안전학회논문집
    • /
    • 제10권2호
    • /
    • pp.1-6
    • /
    • 2017
  • 사물 인터넷(IOT)을 기반으로 한 지하철 재난 조기경보 및 승객 대피를 위한 재난전조 시스템 개발 연구가 이미 선행연구를 통해 수행하였다. 본 논문에서는 역에 설치된 센서 데이터를 분석하여 재난을 신속 하게 감지하기 위한 후속 연구이다. 특히, 본 연구는 초기 시스템 구축 시 센서의 설치 위치에 따라 다를 수 있는 환경변화를 고려한 마할라노비스 거리를 기반으로 통계적 방법론을 개발하였다.

도시철도 이기종 차지상간 네트워크에 VoiceXML의 적용방안 연구 (A Study on Adapting Method of VoiceXML in Urban Transit Heterogeneous Subway & Railway Networks)

  • 이문호;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1993-1998
    • /
    • 2009
  • Recently, with expansion and advent of the wire&wireless networks has been set up by various heterogeneous networks in urban transit networks. It's focussing on an interworking technology. As same as way, In a subway & railway monitoring system networks has been set up by various heterogeneous technologies such as IEEE802.11 WLAN, IEEE802.15 WPAN, DVBT, UWB, BinaryCDMA, ZigBee. These heterogeneous technologies is deeply investigating for the purpose of interworking and easy control as a research area. In this paper, we propose using VoiceXML based of XML for ensure interworking within heterogeneous subway & railway networks. Therefore It will be provide service for staff who has moving and anywhere, anytime in outside. Eventually, we expect that confirm efficiency of effective system through this study.

  • PDF

프리스트레인 가변형 광섬유센서를 이용한 지하철 구조 모니터링시스템 (1Monitoring system for the subway structures using pre-strain controllable FBG sensors)

  • 김기수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.700-709
    • /
    • 2009
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well.

  • PDF

지하철 화재 사례분석에 따른 사고대응방안에 대한연구 (A study on the confrontation plan of accident through the subway fire instance analysis)

  • 김명규;한성호;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.997-1004
    • /
    • 2005
  • Representative of Korean accidents is that occurrence number of accidents is not many. But the extra-large size disaster like as Taegu subway accident are occurred continuously from multi place. It brings a big problem that people has spirit shock and a life damage nationally and socially. The problem point which brings like this tragic death is caused from the fire confrontation system of absent and human confrontation mistake. Therefore, we need the confrontation plan to overcome these accidents. It will be able to prepare favorably in accident confrontation. In this paper, we analyzed fire accidents case study on domestic and oversea and proposed the plan which confronts encounter to fire accidents in subway system urgently and properly.

  • PDF

지하철 직류 급전시스템의 표유전류 실태조사 (On-site Investigation of the Stray Current Condition in DC-Powered Subway System)

  • 하윤철;배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.373-375
    • /
    • 2003
  • The subway, a typical electrified transit, is operated by the 1500 V DC-powered system with the overhead positive feeder and the rails negative return. This return path would bring about considerable stray current circuits, that is, from the bottom of rails to sell and then to the station ground, unless the rail-to-soil resistance is sufficiently high. The stray current can cause electrolytic corrosion of subway metallic structures and adjacent underground utilities. In this paper, we reports on-site investigation of the stray current condition, especially influenced by drainage method. The drainage method including both forced drainage and polarized drainage, extensively adopted as a countermeasure for electrolytic corrosion of underground pipelines, was found out to exert a harmful influence upon rail components as well as the pipelines.

  • PDF

인공자연광을 이용한 지하역사 환경개선 방안 연구 (A Study on Improvement of Means of Realization of Train Destination Equipment System)

  • 여용주;윤인영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.352-357
    • /
    • 2008
  • Using the artificial sun, namely the BIOSUN, we can control the sun light according to the latitude and longitude and for the seasonal changes and apply that to subway stations. By doing this, we can expect three effects, a. allowing the plants to grow inside the stations which will in turn contribute to improving air purity, controlling humidity, and reducing dust for pleasant environment, b. pleasant environment will foster positive emotional responses of the passengers and that would increase the satisfaction, and c. fostering good service for the citizenry and establishing an environmental friendly image of the Seoul Metro Subway System. The purpose of this thesis paper is to contemplate on the uses of the artificial sun powered by the microprocessor of a Light Emitting Diode (LED) in controlling the light and how the light can be utilized in facilitating photosynthesis that would allow plants to grow inside subway stations.

  • PDF

도시철도 역무실 통합 안전관리시스템 디스플레이의 Ecological Interface Design Prototype 개발 (Development of Ecological Interface Design Prototype on Integrated Safety Management System Display in Subway Station Office)

  • 이봉근;백지승;조성식;명노해;이덕희
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.661-665
    • /
    • 2010
  • Current subway station's office employee must perform safety management tasks by monitoring the various safety management systems. But these monitoring systems are limited in effective situational awareness and response to a state of emergency immediately. It is necessary to develop an integrated safety management system display. In this study, we developed subway station safety management system's (CCTV, fire detection & alarm system, screen door control equipment) integrated prototype display with ecological interface design framework and evaluated prototype display interface's usability with GOMS model. The result was that the ecological interface's performance was better than existing safety management system's interface.

Groundwater system Investigation of the Cheonggyecheon watershed Area

  • Choi, Doo-Hyung;Yang, Jae-Ha;Jun, Seong-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.326-329
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of the groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze the influence on the‘groundwater’ below the Cheonggyecheon watershed by the‘maintenance water’on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and the amount of leakages into subway stations and its influence on the groundwater system. Results show that groundwater level was influenced by the direction and depth of subway tunnel. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in the Cheonggyecheon watershed.

  • PDF