• Title/Summary/Keyword: subway

Search Result 2,103, Processing Time 0.033 seconds

Concentration of Sulfur dioxide ($SO_2$) of Subway Stations in Seoul (서울지역 지하철역 구내의 아황산가스 농도)

  • 손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 1999
  • This study was performed to survey the $SO_2$ level at several underground spaces connected to 5 subway stations (City Hall, Nam, Seoul stations, Hye Hwa and Ulchiro 1 Ga) in Seoul. The period of survey was from July to November, 1997.The results of the study were as follows; 1. The mean concentration of $SO_2$ was $0.057{\pm}0.015ppm$ in all subway stations. The highest $SO_2$ level among the five stations was $0.067{\pm}0.011 ppm$ at City Hall (P<0.01), and the highest with $0.071{\pm}0.013ppm$ at November (P<0.01).2. In underground shopping centers, the mean concentration of $SO_2$ was $0.112{\pm}0.059ppm$. 3. The mean concentration of $SO_2$ at evening with 0.057 pp and morning with 0.053 ppm were significantly higher than at noon with 0.043 ppm(P<0.05). 4. The $SO_2$ level of floor at Kang Nam station with 0.044 ppm was significantly higher than that of platform with 0.37 ppm(P<0.01). 5. For the City Hall stations, the line #1 and line #2 subway spaces show significantly different level of $SO_2$, 0.042ppm and 0.033 ppm respectively (P<0.05).

  • PDF

Implementation of Indoor Air Quality Monitoring System for Subway Stations (지하철 역사 공기질 모니터링 시스템의 구현)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of $PM_{10}$, $CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.

서울시 지하철구간내 지하수위강하에 따른 지하공간 환경오염 감시의 필요성 및 대책

  • 이기철;김윤영;이주영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.167-172
    • /
    • 2002
  • Seoul subway system has been constructed to solve traffic difficulties of Seoul metropolitan, and now is the major public transportation. However, the more line has added in the system the deeper the bottom of the tunnel base. And a huge amount of groundwater along the line has seeping into the tunnel. Several subway stations has pumping system to extract the groundwater to the outside and consequently, groundwater table along the line has declined gradually. Groundwater table has dropped about 40 meters at some areas, There was some study for the proper usage of the abstracted groundwater and the project to use the groundwater has launched already by the local government. However. more serious problem is expected on quality degradation of soil and groundwater as the decline of groundwater table along the subway line. This study suggests that the detailed groundwater environmental study should be made as soon as possible for this. If there is any pollution leaking at the surface area of the groundwater depression, the pollution will be seep into the subway tunnel in some day even though the time will be different with the soil material and hydraulic characteristics of the aquifer. And the polluted area of the soil and groundwater would be enlarged along the pathway The study on possibility of the soil subsidence and reducing surface water flow in small creek were also needed. This study suggest one of the counter measurement that restoring the declined groundwater table after groundwater environmental study

  • PDF

The Meeting Plaza Design around "Myeonmok" Subway Station, Seoul (면목역 만남의 광장 설계)

  • Kim, Sung-Kyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.1 s.120
    • /
    • pp.20-27
    • /
    • 2007
  • This paper presents a landscape design for the meeting plaza around the "Myeonmok" subway station. The site is located at 120-1 Myeonmok 1-dong, Jnngrang-gu, Seoul, and its area is approximately $2,664.7m^2$. The goal of the design was to make an environmentally friendly meeting and rest place which was related to the subway station. To achieve this goal, concepts of history, tradition, sense of place, community, environmental friendliness, and function were developed. For history, stone sculpture and art tiles symbolizing the paleolithic area were introduced because the site is located near an archaeological site of paleolithic min. For tradition, considering that the site is a 'sailing ship' form in terms of Pungsu theory, a sculpture symbolizing a sailing ship and paving patterns symbolizing waves were introduced. For asense of place, a grass hill, a waterfall and a pond symbolizing an old meadow for horse pasture was introduced. In addition, a multi-purpose round plaza as a meeting place for local community and subway users was proposed. A zelkova grove symbolizing a village forest was proposed for a restand relaxation area. All areas were designed to be environmentally friendly and barrier-free. Concepts for a defensible space wereadapted for safety because the site was a crime-prone area.

Study on the environment design element of Japan subway station wall - Laying stress on techniques of ceramic mural that is manufactured in 2000 years - (일본 지하철 역 벽면의 환경디자인 요소에 관한 연구 - 2000년도에 제작된 도자 벽화의 기법을 중심으로 -)

  • 이병수
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.170-173
    • /
    • 2003
  • Because effect about environmental effect that get to human visually is absolute, ability that mural of subway interior considers relation with space is required. Also, public environment element should be designed must intend agreeableness sex by same traitor effect of quality of the material and color and can be evaluated by cultural inheritance that is powerful enemy same time. Wish to accomplish access as meaning of city environment improvement of wall of subway station or underground space etc. through Japan course South Korea's illustration regarding environment landscaping features that is designed in wall of latest domestic building subway interior in this research. Various and new reading by that study and analyze manufactured wall environment landscaping features recently that could find and was approached in variouser technique, practical use of material than single material and is expressed according to history's special quality and planning know can. Underground space can give agreeableness feel and psychological sense of security by user though expression method, material, color plan etc. consist because is having image blockade enemy. Therefore, wall environment landscaping features of underground space to be cultural value and environment Dija because diversified research that is accompanied in element is gone subway interior space of our country and underground space etc. as new culture space develop be able to must.

  • PDF

Stability Analysis of Existing Tunnel in Stratified Sedimentary Rocks Subjected to Bridge Pier Load (퇴적암 지역에서의 교각 기초 하중을 받는 기존터널의 안정성에 대한 해석적 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.153-161
    • /
    • 1998
  • An anisotropic characteristics of stratified sedimentary rocks should be considered in the design of tunnel. The second line of Taegu subway is under construction through the sedimentary rocks which is stratified by alternation of shale and sandstone, and Tongsoe over bridge road is planned to be constructed along the subway line. Thus the subway twin tunnels will be subjected by the bridge load of 76.2 MN per pier that will be placed in between the twin tunnels of the subway line. A numerical analysis is carried out for the stability of the twin tunnel, and the result shows that the maximum principal stress of surrounding ground is increased by 5∼6 MPa and the additional displacement of concrete lining is reached up to 8∼10mm due to the external bridge load. For the safety operation of the subway, reinforcement of the tunnel structure is highly recommended.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

Dynamic Response of Building Structures Induced by Subway Operation (지하철 진동에 의한 건축구조물의 진동특성)

  • 김희철;이동근;민경원
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.95-106
    • /
    • 1995
  • Noise and vibration induced by subway operation are one of the major factor that annoy residents living near the subway tracks. In general, lateral vibration is the major concern when we are considering vibration of a building. However, the vertical vibration is the major concern in considering the vibration induced by the subway operation. Analysis model for the vertical vibration of the structure should consider the effect of beam vibration. Thus, the same model used for the lateral vibration analysis can not be used for an analysis of vertical vibration of the structure. Appropriate analysis model which can consider the inertia force of the beam is necessary when analyzing a structure for the vertical vibration. Modeling technique for the vertical vibration analysis of structures has been studied on this paper. It is recommended to use one or more elements for columns and to use two or more elements for beams when analyzing structures for vertical vibration induced by subway operation.

  • PDF

Guidance system improvement method of subway and urban bus (도시철도 및 버스의 안내체계 개선방안)

  • Han, Woo-Jin;Kwon, O-Hyeon;Park, Jeong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1777-1782
    • /
    • 2007
  • Since July in 2004, starting with urban bus reorganization of Seoul metropolitan government, the change of the public transportation which integrates the urban bus and the subway of the metropolis are being continued. But the integration of such bus and the subway is staying to only a fare system mainly, and the guidance system of the subway and the bus has not changed. So we propose the concept of the new guidance system following public transportation change tendency. At first we introduce the new information system which can guide city railroad and bus altogether, and we propose new system which can guide divided by the trunk line and the branch line instead of bus and subway. Last high-functional guidance system which can give passengers tip and hint for various and effective usage of public transportation in more complicated city transit network is introduced. This new guidance system can increase competitiveness of public transportation system and stretch transportation share of it. And that guidance system is high-class contents that all public transportation business can utilize, so it can originate new industry. In conclusion, this new innovative guidance system is important field that government, local administration and public transportation business must be concerned and develop.

  • PDF

A Numerical Study on Passengers' Evacuation in a subway station in case of Fire Occurrence (화재 발생 지하철 역사에서의 여객 대피 해석에 관한 연구)

  • Kim, Chi-Gyeom;Lee, Sung-Won;Hur, Nahm-Keon;Nam, Seong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.142-147
    • /
    • 2009
  • In the present study, a numerical simulation of passenger evacuation in a subway station was performed. Algorithm for passenger flow analysis based on DEM(Discrete Element Method) has been improved to simulate passenger flow in detailed geometry. The effect of grid density was assessed in the present study to show the advantage of using finer grid in the simulation. The method of coupling passenger flow and fire simulation has also been investigated to analyze passenger evacuation flow under fire. In this method the CO distributions in the subway station was used to assess fire hazards of passenger by means of FED(Fractional Effective Dose) model. Using the coupled algorithm a simulation for passenger evacuation flow and fire analysis were performed simultaneously in the simplified subway station. This algorithm could be used in the design of subway station for the purpose of passengers' safety in case of fire.

  • PDF