• Title/Summary/Keyword: subtractive

Search Result 289, Processing Time 0.023 seconds

The linguistic and cultural phenomena derived from the interpretative ambiguity in the traditional Catalan time telling expressions (카탈루냐어의 전통적 시각표현의 해석적 모호성과 관련된 언어-문화적 현상)

  • Kwak, Jaeyong
    • Cross-Cultural Studies
    • /
    • v.50
    • /
    • pp.225-259
    • /
    • 2018
  • In this study, according to the Institut d'Estudis Catalan, it is noted that the traditional Catalan time telling system is essentially based on delineating time by the use of the 'quarts (=quarters)' of an hour. In this fasion, to tell the time 8:15, 8:30 and 8:45 they use '${\acute{E}}s$ un quart de nou.,' '$S{\acute{o}}n$ dos quarts de nou.,' and '$S{\acute{o}}n$ tres quarts de nou.,' but do not use constructions such as '$S{\acute{o}}n$ les vuit i quinze.,' '$S{\acute{o}}n$ les vuit i trenta/mitja.,' '$S{\acute{o}}n$ les vuit i quaranta-cinc.,' because these expressions are considered to be as dialectal variants or international notation-based variants. Moreover, the traditional Catalan time telling system does not use cardinal numbers, except in the case of 'cinc (five)' and 'deu (ten).' These linguistic phenomenon cause the invention of a unique Catalan digital watch, and has noted special designs for the creation of a Catalan analogue watch. For this reason, the quarter system in colloquial Catalan provokes an enormous interpretative ambiguity in daily routine expressions with 'quarts' like '$S{\acute{o}}n$ quarts of nou.' or 'entre dos i tres quarts' whose meaning is not delineated between sixteen and forty-four minutes. We will argue that the traditional Catalan time telling expressions do not have the use of the subtractive system, and the fraction word 'quart' lacks a specific meaning of fifteen minutes because the Catalan word 'quart' is etymologically related to the classical public bell system, not definitively to the traditional clock system.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review (국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰)

  • Yi, Yuseung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.370-378
    • /
    • 2021
  • Purpose. The purpose of this study was to evaluate the currently published literatures investigating the accuracy of computer-aided design and computer-aided manufacturing removable partial denture (CAD-CAM RPD) framework with different manufacturing techniques and methods. Materials and methods. A comprehensive search for literatures was conducted in PubMed database using specific keywords with the patient, intervention, comparison, and outcome (PICO) question, "Is there a difference in accuracy of RPD frameworks manufactured using digital workflow according to the manufacturing process and methods?" Results. A total of 7 articles were selected. Two studies compared intraoral scanning and laboratory scanning for RPD frameworks and had heterogenous results. In the studies using different manufacturing process, RPD frameworks had clinically acceptable accuracy in both subtractive and additive manufacturing. Polyetheretherketone (PEEK)-milled RPD frameworks showed higher fit accuracy than traditionally casted or 3D printed RPDs. Direct milling method showed a higher accuracy than indirect milling method. However, in rapid prototyping, indirect method showed higher accuracy than direct method. Conclusion. The RPD frameworks fabricated using CAD-CAM technology showed a clinically acceptable level of accuracy regardless of manufacturing process or techniques. Consistent results have not been reported regarding the digital impression methods, which were intra oral scanning or laboratory scanning, and further studies are needed.

Psychological functions and values of counterfactual thinking (사후가정사고의 심리적 기능과 응용적 가치)

  • Taekyun Hur
    • Korean Journal of Culture and Social Issue
    • /
    • v.8 no.2
    • /
    • pp.171-190
    • /
    • 2002
  • Counterfactual thinking refers to a mental simulation of "What might have been," a cognitive process of once-possible-but-unrealized alternatives to facts, Counterfactuals have been reported to produce intensive emotional experiences, specifically regret. The present research reviewed and tried to integrate the previous inconsistent findings in the view of functional value of counterfactuals. Social psychologists proposed that counterfactuals could be categorized into upward(thoughts of better alternatives) versus downward(thoughts of worse alternatives) and additive versus subtractive. Counterfactual processes are more likely to occur following negative or unexpected rather than positive expected outcome, consistent with the minimization-mobilization hypothesis. Downward counterfactuals serve affective functions(to make one feel better) through contrast effects. Upward counterfactuals serve preparative functions(to prepare and improve performance in the future similar tasks) through causal inferences. Also, upward counterfactuals have been demonstrated in several studies to be followed by success-related attitudes and intentions and actual performance improvement. Furthermore, in terms of regulatory focus, downward counterfactuals were related with the prevention focus(to maintain the current status and upward counterfactuals were related with the promotion focus(to improve the current status). Those findings from numerous studies support that counterfactuals are functional to serve human ongoing motives. In conclusion, applicability and limitation of functional value of counterfactual thinking were discussed.

  • PDF

Fabrication of complete denture using conventional method and monolithic digital denture system: a case report (전통적 제작법과 모놀리식(monolithic) 디지털 의치 시스템을 이용한 상·하악 총의치 동시 수복 증례)

  • Young-Baek Park;Ga-Hyun Lee;Young-Gyun Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.6-19
    • /
    • 2024
  • With the advancement of Computer-Aided Design/Computer-Aided Manufacturing (CAD-CAM) technology, fabrication of dentures using this technology has gained popularity. As one of CAD-CAM technologies, digital complete denture system has been introduced, which fabricates complete dentures using subtractive manufacturing of monolithic block containing both the color of a denture base and an artificial tooth. In this case, two pairs of upper and lower dentures were fabricated for two patients. Two pairs of complete dentures were fabricated for a 74-year-old male and a 73-year-old female respectively by conventional denture fabrication method and digital method of milling. To obtain a digital complete denture, monolithic block (Ivotion, Ivoclar Vivadent, Schaan, Liechtenstein) was chosen for the materials to fabricate the digital complete dentures. An individual tray was designed using CAD software and manufactured by 3D printing technique. The final impression and interocclusal relationship were recorded using the fabricated individual tray. The final impression was scanned, and the complete denture design and try-in denture were 3D printed using CAD-CAM software. Subsequently, the monolithic block was milled, and the final dentures were fabricated and tried on patients. Previously mentioned two patient cases compared and analyzed stability, fit, speaking, mastication, aesthetics, and patient satisfaction of two pairs of dentures: one fabricated using CAD-CAM system and the other using traditional methods. This was performed to evaluate and report the findings from both denture-making approaches.

Genetic Expression of Color Approved by Color Qualities of Munsell System on the Cocoon of Silkworm, Bombyx mori (누에 고치색 유전자 발현의 다양성 검정 및 색채과학적 해석)

  • Han, Myung-Sae;Park, Hyun-Ro;Han, Sang-Mi;Nam, Ki-Soo;Kwon, Soon-Ha;Lim, Jong-Sung;Nguyen, Mau Tuan
    • Journal of Sericultural and Entomological Science
    • /
    • v.41 no.1
    • /
    • pp.20-28
    • /
    • 1999
  • Color qualities investigated on the basis of Munsell code and Korean standard color code for the cocoons from various strain of mulberry silkworm, Bombyx mori. 16 of different color qualities were identified from 21 of original silworm strains, and determinated international name with the revision of Korean color name for cocoon. The various cocoon color confirmed on the sphere from 567 to 593 nm wavelength, 78% of those located at the region about 580 nm (575~584) of sensitive "color difference limen". Y gene engaged broad ranges of wavelength (575~593 nm) in the color expression, by contrast with other genes of Pk (593 nm), F (584~593), Grc and relative G group (567~570 nm), on the transmission of carotenoid or flavonoid color substance. YC gene expression by original silk worm strain was also distinguished by those variation of specific yellow than other colors from Grc, GaGb, Gc, and YPkF. Appearance of chrome yellow cocoon was dominant than other yellow in the cross among vivid yellow group. F1 of pin${\times}$green produced the cocoon of yellow such as "additive mixture" as color light, however, most of the hybrid between yellow cocoon showed the color similar to "subtractive mixture" as a mixture of dyestuff. Hybrid cocoons among yellow or green colors were decreased their hue, value, and chroma, than those of parent. Diallel cross among the strain of various green cocoon suggest the existence of Grc, Ga, Gb, Gc genes. Cream colored cocoon of B. mandarina was differed from other yellow cocoon of Bobyx mori B. mori. Y$^A$ with Ymc showed the similar role of Y with C, therefore, segregated yellow cocoon from the B. mori${\times}$B. mandarina (+$^YC/Y^AYmc$). YC expression of $Y^AY$mc genes might be suppressed by deficiency of outer layer sericin on the middle division of silk giand in the B. mandarina.

  • PDF

A Study on the Screening of the Novel Genes Associated with Lysosomal Trafficking and Mutation Detection in Fibroblasts of the Patients with Mucolipidosis type II and III (리소좀 교통 이상을 초래하는 뮤코지방증 2형과 3형 환자의 섬유아세포를 이용한 신규 유전자 탐색 및 돌연변이에 대한 연구)

  • Song, Seng Mi;Chang, Soo Hee;Paik, Kyung Hoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.5 no.1
    • /
    • pp.65-75
    • /
    • 2005
  • Purpose: To understand genetic differences and similarities between mucolipidosis and control. Methods: Using the fibroblast of the mucolipidosis II and control, forward and reverse subtracted libraries were constructed. Among these clones, we investigated mutations in the GNPTA (MGC4170) gene, which codes for the ${\alpha}/{\beta}$ subunits of phosphotransferase, and in the GNPTAG gene, which codes for the ${\gamma}$ subunits in 5 Korean patients with mucolipidosis type II or IIIA. Result: Several differentially expressed cDNAs were cloned and their sequences were determined. Mutation analysis of the interested gene, GNPTA was performed and we identified 7 mutations in the GNPTA gene, but none in the GNPTAG gene. The mutations in type II patients included p.Q104X(c.310C>T), p.R1189X(c.3565C>T), p.S1058X(c.3173C>G), p.W894X(c.2681G>A) and p.H1158fsX15(c.3474_3475delTA), all of which are non-sense or frame shift mutations. However, a splicing site mutation, IVS13+1G>A (c.2715+1G>A) was detected along with a non-sense or a frame shift mutation (p.R1189X or p.E858fsX3(c.2574_2575delGA)) in two mucolipidosis type IIIA patients. Conclusion: This report shows that mutations in the GNPTA gene coding for the ${\alpha}{\beta}$subunits of phosphotransferase, and not mutations in the GNPTAG gene, account for most of mutations found in Korean patients with mucolipidosis type II or IIIA.

  • PDF

Control of Trophoblast Gene Expression and Cell Differentiation

  • Cheon, Jong-Yun
    • 대한생식의학회:학술대회논문집
    • /
    • 2001.03a
    • /
    • pp.195-205
    • /
    • 2001
  • 태반 영양배엽 (trophoblast)은 포유동물의 발생과정 중 가장 먼저 분화되는 세포로서, 자궁환경내에서 배아가 착상, 발생, 및 분화하기 위해서 반드시 필요한 태반을 형성하는 색심적인 세포이다. 영양배엽 세포의 분화과정중의 결함은 배아의 사산이나 임신질환 등의 치명적 결과를 초래한다. 하지만, 영양배엽 세포의 분화를 조절하는 분자생물학적인 메카니즘은 아직 규명되지 않고 있다. 영양배엽 세포의 분화를 조절하는 경로를 규경하기 위한 선결과제는 분화된 영양배엽 세포에서만 발현하는 많은 유전자들이 밝혀져야만 한다. 본 연구팀은 최근에 분화된 영양배엽 세포에서만 발현하는 두 종류의 새로운 유전자들을 찾았다. 한 종류는 homeobox를 보유하고 있는 조절 유전자 Psx이고, 다른 한 종류는 임신호르몬인 태반 프로락틴 라이크 단백질 유전자 PLP-C${\beta}$이다. 본 연구과제의 목표는 이들 유전자의 기능과 조절 메카니즘을 규명함으로써, 영양배엽 세포의 분화를 조절하는 조절경로를 밝히는 것이다. 이를 위하여 다음과 같은 일련의 연구를 수행할 것이다. 1) Psx 유전자가 분화된 영양배엽 세포에서만 발현케 하는 조절 메카니즘을 규명하기 위해 functional assays, in vitro footprinting, gel mobility shift assays, 생쥐형질전화, UV crosslinking, Southwestern blot 등의 방법을 통해 Psx 유전자의 cis-acting 요인과 trans-acting factor를 밝혀 분석한다. 2) 영양배엽 세포의 분화조절 경로를 규명하기 위해 random oligonuclotide library screening, DD-PCR, subtractive screening 등의 방법을 이용하여 Psx 유전자에 의해 조절되는 하부유전자를 밝힌다. 3) Psx 유전자를 knock-out시켜 영양배엽 세포가 발달 및 분화하는데 미치는 역할을 밝힌다. 4) Yeast two-hybrid screening방법을 이용하여 태반 프로락틴 유전자의 수용체를 찾아 이들의 신호전달 기전을 밝힌다. 제1차년 연구결과로서, mouse와 rat으로부터 각각 Psx 유전자의 genomic DNA를 클로닝하여, 유전자 구조를 비교한 결과, mouse Psx (mPsx2)는 4개의 exons으로 이루어져 있는 반면에, rat Psx (Psx3)는 3개의 exons으로 구성되어 있었다. 즉, rPsx3는 mPsx2의 exon1이 없었다. Notrhern blot과 in situ hybridization 분석에 의해 mouse와 rat에서 Psx 유전자가 다르게 발현 조절되는 현상을 밝혔다. 실제로 mPsx2와 rPsx3의 5'-flanking지역을 클로닝하여 염기서열 분석 결과 전혀 homology를 찾을 수 없었다. 또한, 이들 각각 promoter의 activity를 luciferase reporter를 이용하여 조사한 결과 Rcho-1 trophoblast cells에서 각기 다른 activity를 보여 주는 것을 발견하였다. Psx 유전자의 transcription start sites는 Primer extension에 의해 밝혔다. 또한 Psx2 유전자를 knock-out 시키기 위해 targeting vector를 Osdupde1에 제작하였다. 본 과제를 시작할 때 새로운 프로락틴 유전자 하나를 클로닝하여 이 유전자를 PLP-I라고 이름을 붙였다. 이 후 이 유전자 (PLP-I)는 PLP-C${\beta}$라고 이름을 붙이게 되었다. Mouse PLP-C${\beta}$ 유전자의 counterpart를 rat에서 찾아 염기서열을 비교한 결과 mouse와 rat에서 PLP-C${\beta}$유전자의 homology는 약 79% (amino acid level)였다. 본 연구과정을 통해 또 하나의 새로운 PLP-C subfamily member를 mouse로부터 클로닝 하였고, 이 유전자를 PLP-C${\gamma}$라 하였다. PLP-C${\beta}$와 PLP-C${\gamma}$의 발현 유형은 Northern blot과 in 냐셔 hybridization 분석에 의해 태반의 제한된 spongitrophoblast와 trophoblast giant cells에서만 발현하는 것을 밝혔다. 놀랍게도 이들 두 새로운 유전자는 alternative splicing에 의해 두 종류의 isoform이 있음을 밝혔다. PLP family member 유전자로서 splicing에 의한 isoforms을 보여 주는 유전자로는 PLP-C${\beta}$와 PLP-C${\gamma}$가 최초이다. 이들 isoform mRNAs의 발현 유형은 RT-PCR 방법을 이용하여 규명하였다. 또 하나의 새로운 발견은 PLP-C${\beta}$와 PLP-C${\gamma}$가 독특한 유전자 구조를 갖고 있었다. 즉, PLP-C${\beta}$는 exon3의 alternative splicing에 의해 5개 혹은 6개의 exons을 갖는 two isoforms이 생긴다. 반면에 PLP-C${\gamma}$는 exon2가 alternative splcing이 되면서 7개의 exons을 갖거나 6개의 exons을 갖는 isoforms을 만든다. 그리고, PLP-C${\gamma}$의 promoter activity를 trophoblast Rcho-l${\gamma}$ 세포주를 이용하여 PLP-C${\gamma}$ 의 1.5 kb 5'-flanking 지역이 trophoblast-specific promoter activity를 갖고 있음을 밝혔다. PLP-C${\gamma}$ 유전자의 transcription start site는 Primer extension에 의해 밝혔다. 제 1차 년도의 연구결과를 토대로, 2차년에서는 다음단계의 연구를 수행하고자 한다. 즉, 1) mPsx2와 rPsx3의 promoter를 비교분석 함으로서 mouse와 rat에서 Psx 유전자가 다르게 조절되는 메카니즘 규명, 2) Psx와 PLP-C 유전자의 promoter에 있는 cis-acting elements 탐색, 3) Psx2와 Psx3의 단백질을 이용하여 이들이 binding하는 target sequence 규명, 4) 제작한 Psx2 targeting vector를 이용하여 ES cells에서 Psx2 유전자 knock-out, 5) Psx 유전자를 과발현시키는 세포주를 만들고 Psx에 의해 조절되는 유전자 탐색, 6) 새로 밝히 PLP-C members 유전자들의 조절기전을 Rcho-1 세포주를 이용하여 여러 거지 성장인자와 다른 호르몬에 대한 반응을 탐색, 7) Psx와 PLP-C${\gamma}$ 유전자의 chromosomal mapping 등을 밝힐 것이다.

  • PDF

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.