• Title/Summary/Keyword: subtraction technique

Search Result 151, Processing Time 0.022 seconds

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

Electrical Compound Action Potential: Effects of different parameters (전기 자극 청신경 복합활동전위: 변인 영향)

  • Heo, S.D.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Electrical compound action potential (ECAP) can be recorded on cochlear implant. This study will investigate stimulation and recording to enhance the efficacy of ECAP. 34 articles was used. We analyzed pulse and stimulating condition, artifact suppression, recording condition. The cathod-leading biphasic pulse was used with as short as possible pulse width and inter phase gap for the efficacy of neural firing, stable threshold and preventing neural degeneration. Around C-level was stimulated to apical, middle and basal turn of cochlea. Artifact was eliminated by forward-masking, template-subtraction technique. For clearer waveform, we need to change distance between stimulating and recording electrode, the gain of amplification, number of average.

  • PDF

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

Development and Application of MEA(Model-Eliciting Activities) Program Applying the Invention Technique(TRIZ): Focus on Students' Conceptual Change (발명기법(TRIZ)을 적용한 MEA(Model-Eliciting Activities) 프로그램 개발 및 적용 -학생들의 개념 변화를 중심으로-)

  • Kang, Eunju
    • Journal of The Korean Association For Science Education
    • /
    • v.42 no.1
    • /
    • pp.161-176
    • /
    • 2022
  • This study developed an MEA program to which the invention technique was applied and analyzed the conceptual change of students. The MEA activity applying the invention technique (TRIZ) was composed of the topic of making a paper electric circuit in the section 'Using electricity' presented in the 6th grade textbook. As a way to materialize ideas for problem solving, among the TRIZ techniques, division, integration, multi-purpose, overlapping, subtraction, and converse techniques were extracted and applied. The devised program consists of examining invention techniques (1st session), problem-solving (2nd and 3rd sessions), and expressing the problem-solving process (4th session). As a result of applying to 6th grade elementary school students, it was confirmed that the scientific concept of the experimental group participating in the MEA class to which the invention technique was applied was improved compared to the control group participating in the general class. As a result of calculating the scientific concept improvement index, the control group showed a low educational effect of 0.15, and the experimental group showed an intermediate educational effect of 0.69. This study is meaningful in that it suggests a specific way to graft invention education into science subjects.

Comparisons of Color Spaces for Shadow Elimination (그림자 제거를 위한 색상 공간의 비교)

  • Lee, Gwang-Gook;Uzair, Muhammad;Yoon, Ja-Young;Kim, Jae-Jun;Kim, Whoi-Yul
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.5
    • /
    • pp.610-622
    • /
    • 2008
  • Moving object segmentation is an essential technique for various video surveillance applications. The result of moving object segmentation often contains shadow regions caused by the color difference of shadow pixels. Hence, moving object segmentation is usually followed by a shadow elimination process to remove the false detection results. The common assumption adopted in previous works is that, under the illumination variation, the value of chromaticity components are preserved while the value of intensity component is changed. Hence, color transforms which separates luminance component and chromaticity component are usually utilized to remove shadow pixels. In this paper, various color spaces (YCbCr, HSI, normalized rgb, Yxy, Lab, c1c2c3) are examined to find the most appropriate color space for shadow elimination. So far, there have been some research efforts to compare the influence of various color spaces for shadow elimination. However, previous efforts are somewhat insufficient to compare the color distortions under illumination change in diverse color spaces, since they used a specific shadow elimination scheme or different thresholds for different color spaces. In this paper, to relieve the limitations of previous works, (1) the amount of gradients in shadow boundaries drawn to uniform colored regions are examined only for chromaticity components to compare the color distortion under illumination change and (2) the accuracy of background subtraction are analyzed via RoC curves to compare different color spaces without the problem of threshold level selection. Through experiments on real video sequences, YCbCr and normalized rgb color spaces showed good results for shadow elimination among various color spaces used for the experiments.

  • PDF

Radioimmunoscintigraphy Using IMACIS-1 in Gastrointestinal Cancer (IMACIS-1을 이용한 위장관 종양의 방사면역신티그램)

  • Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 1990
  • Most of the diagnostic methods currently used for the detection of neoplastic masses provide indirect evidence. To obtain greater specificity in the interpretation of neoplasias by in vivo methods, the immunological approach appears to be most promising. Two problems that interfered with progress in this field were the lack of tumor specific antigen and the lack of well-defined and reproducible antibodies. To improve the sensitivity and specificity of radioimmunoscintigraphy as a technique for tumor localization, the use of monoclonal antibodies, fragments of antibodies and single photon emission computerized tomography (SPECT) are reasonable. The obvious advantages of monoclonal antibodies are their homogeneity, their specificity for the immunizing antigen and the reaction with a single determinant-thus no large immunecomplexes with antigen are formed. Monoclonal antibody technique has recently provided an opportunity to reevaluate the role of nuclear medicine for the diagnosis of malignant diseases by using the immunological approach. Out first results by means of radioimmunoscintigraphy of CEA and CA 19-9 producing tumors using a cocktail of fragments F $(ab')_2$, of mocolonal antibodies to CA 19-9 and CEA labeled with $^{131}I$ (IMACIS-1) are reported. The aims of this investigation was to evaluate the role of immunoscintigraphy in patients with colorectal and other cancers for diagnosis of local recurrences and metastasis. This report contains results of the first 8 colorectal and pancreas cancer patients with the elevation of the level of serum CEA and/or CA 19-9. IMACIS-1 was injected intravenously during 30 minutes in 100 ml saline solution after skin test. Planar scintigrams were recorded 3, 5 and 7 days after the injection of the IMACIS-1. Anterior, lateral and posterior views of the liver as well as anterior and posterior views of the pelvis were obtained in each patients as an $^{131}I-antibody$ image. We were able to localize exactly the malignant process with the double-nuclide double-compound $^{99m}Tc\;^{131}I$ (Tc+l) scintigrams. In Tc & I double-nuclide scintigraphy, computer subtraction display provided more clear localization of the tumor. We compared the results of radioimmunoscintigraphy with CT, ultrasonograms, conventional scintigrams. The results were as follows: 1) The sensitivity and specificity of radioimmunoscintigraphy using the fragments $F(ab')_2$ of the cocktails of CEA and CA 19-9 monoclonal antibodies were 80% and 100% respectively. 2) Tumor detection rate was not proportionated to the level of serum tumor markets. 3) Second tracer technique was essential for tumor localization as an anatomic landmark using double-nuclide scintigraphy. 4) A slow infusion of the antibodies was necessary to prevent the formation of large immune complexes. 5) Tumor/non-tumor radioactivity was most elevated at 7 days delayed imaging. 6) Using planar scintigraphic technique of $^{131}I$ labeled monoclonal antibodies are possible for imaging most of the tumors.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.

Edge-Based Tracking of an LED Traffic Light for a Road-to-Vehicle Visible Light Communication System

  • Premachandra, H. Chinthaka N.;Yendo, Tomohiro;Tehrani, Mehrdad Panahpour;Yamazato, Takaya;Fujii, Toshiaki;Tanimoto, Masayuki;Kimura, Yoshikatsu
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.475-487
    • /
    • 2009
  • We propose a visible light road-to-vehicle communication system at intersection as one of ITS technique. In this system, the communication between vehicle and a LED traffic light is approached using LED traffic light as a transmitter, and on-vehicle high-speed camera as a receiver. The LEDs in the transmitter are emitted in 500Hz and those emitting LEDs are captured by a high-speed camera for making communication. Here, the luminance value of each LED in the transmitter should be found for consecutive frames to achieve effective communication. For this purpose, first the transmitter should be identified, then it should be tracked for consecutive frames while the vehicle is moving, by processing the images from the high-speed camera. In our previous work, the transmitter was identified by getting the subtraction of two consecutive frames. In this paper, we mainly introduce an algorithm to track the identified transmitter in consecutive frames. Experimental results using appropriate images showed the effectiveness of the proposal.