• Title/Summary/Keyword: subsurface dam

Search Result 37, Processing Time 0.027 seconds

Trend and Barrier in the Patents of Artificial Recharge for Securing Goundwater (지하수자원 확보를 위한 인공함양 기술 특허동향 및 장벽 분석)

  • Kim, Yong-Cheol;Seo, Jeong-A;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.59-75
    • /
    • 2012
  • It is getting difficult to manage water resources in South Korea because more than half of annual precipitation is concentrated in the summer season and its intensity is getting severe due to global warming and climate change. Artificial recharge schemes can be a useful method to manage water resources in Korea adapting to climate change. Patent analysis enables us to prevent overlapping investment and to find out unoccupied technology. In this study, international patent trends and barriers of artificial recharge technology are analysed for patents of Korea, Japan, the United States and Europe. The four artificial recharge methods such as well recharge, surface infiltration, bank filtration and underground structures are classified as main class and the nine sub-technologies such as water intake, water treatment, injection wells, monitoring of groundwater flow, groundwater pumping, surface infiltration/soil aquifer treatment, radial collection well, iron/manganese treatment, and underground subsurface dam are classified as intermediate class. Water intake techniques are subdivided into five classifications. Total 1,281 of patents, searched by WIPS DB tool and selected after removing noisy patents, are analyzed quantitatively to evaluate application trends by year, applicant, country for each classified technologies and analyzed qualitatively to find out occupied and unoccupied technologies. It is expected that upcoming research and development project could be performed efficiently in that an avoidance plan for the similar patents and differentiation plan for the advancing patents are set up based on the quantitative and qualitative analysis results from this research.

Effective Use of Water Resources Through Conjunctive Use - (II) Application (지표수-지하수를 연계한 수자원의 효율적 이용 - (II) 적용)

  • Kim, Su-Min;Lee, Sang-Il;Kim, Byeong-Chan
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.10
    • /
    • pp.799-812
    • /
    • 2004
  • Conjunctive use of surface and ground water has drawn much attention as a promising means to solve water shortage problems. Characterized by its maximum utilization of regional resources and environmental friendliness, conjunctive use is expected to contribute to the integrated water resources management in the coming era. This paper examines the applicability of the methodology for conjunctive use developed in the companion paper (this issue). The method consists of the entire process of conjunctive use, including site assessment using analytic hierarchy process, management scenario development based on drought analysis, and evaluation of benefits obtained. Sokcho City was chosen as the study area, and the application of derived operation scenarios for surface and subsurface reservoirs revealed that water of 4.9∼7.4 million cubic meters a year can be attainable additionally. The developed methodology enables one to devise management schemes and to quantify their effectiveness, which makes the method useful for water resources planners as well as practitioners.

A study on the analysis of groundwater falling by subsurface dam (지하댐 건설로 인한 주변부 지하수위 하강 분석 연구)

  • Oh, Jun Oh;Young, Jeon Ju;Park, Jae Hyeon;Jun, Sang Mi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.117-117
    • /
    • 2017
  • 울산시는 반구대 암각화 보존과 시민들을 위한 청정원수 공급과의 갈등을 지난 20년간 논의해 왔다. 이는 반구대 암각화 보존을 위하여 사연댐 수위를 낮추어 관리하여 발생하는 12.0만$m^3$의 용수부족량분과 장래 용수부족량분 30.0만$m^3$에 대하여 낙동강원수를 사용하여야 하는데 사연댐에 비해 수질이 나쁜 낙동강 원수사용의 비율이 높아지면 정수비용 증가로 인한 시민의 부담이 증가한다는 울산시의 입장과 반구대 암각화 보존을 위하여 사연댐의 수위를 낮추어 관리해야 한다는 문화재청의 입장으로 마찰을 빚어왔다. 이에 울산시의 신규 수자원 개발의 필요성이 대두되었고 그 방안으로 지하댐건설이 하나의 대안으로 제시되었다. 이에 본 연구에서는 울산시 울주군 사연리 주변에 지하댐이 건설된다면 그 주변 지하수위 변화에 대하여 지하수 모델(Visual-MODFLOW)를 사용하여 분석하였다. 먼저 울산시 울주군 사연리 인근에 지하댐을 건설한다면 일 30.0만$m^3$의 취수가 가능한지에 대한 여부를 분석하였으며, 가능하다면 용수취수로 인한 주변부 지하수위 하강이 어떻게 발생하는지에 대하여 분석하였다. 그 결과 일 30.0만$m^3$의 용수취수가 가능한 것으로 분석되었으며, 그로 인한 지하수위 하강은 취수정이 설치된 지점에서는 최대 1.8m의 지하수위 하강이 발생하며, 그 영향반경은 약 50.0m인 것으로 분석되었다. 또한 지하수위 하강이 약 0.3m ~ 1.8m까지 발생하는데 그 반경은 최대 약 700.0m 인 것으로 분석되었다. 본 연구 결과를 바탕으로 울산시 신규 수자원 개발을 위하여 지하댐을 건설이 가능할 것으로 판단되며 만약 울산시 신규 수자원으로 지하댐을 건설한다면 추가 정밀조사를 통하여 정확한 지하수위 변동 특성을 분석해야 할 것으로 판단된다.

  • PDF

Study of Continuous Monitoring for Underground and Geotechnical Structures using Accelerometers (가속도계를 활용한 지하 및 지반구조물 상시 계측 방안에 관한 연구)

  • Gunwoong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.19-27
    • /
    • 2024
  • Geotechnical structures such as dams, tunnels, and slopes require regular inspection and monitoring to ensure stability. Domestically, drones and accelerometers have become common tools for inspecting and monitoring various structures. However, drones have difficulty identifying internal changes in structures and the subsurface, and accelerometers generally serve for seismic design or strain measurement purposes. Therefore, this paper proposes to utilize accelerometers to monitor the internal information of the ground on a real-time or periodic basis. The proposed method utilizes a part of the analysis technique from the SASW test to monitor the stability and state changes of geotechnical structures. Cases where SASW was used to evaluate the safety of geotechnical structures, such as slopes, dams, and tunnels, were reviewed to verify the suitability of the technology. To make the proposed method more practical, the study considered using only the first-step analysis to derive the dispersion curve rather than the second-step analysis to determine the shear wave velocity profile, which requires complex analysis. The proposed technique is expected to enable the continuous monitoring and inspection of geotechnical structures by utilizing accelerometers.

A Development of Dielectric Measurement System for Detecting Physical Parameters of Ground in Subsurface Dam (지하댐 지반 물성치 측정을 위한 유전율 측정 시스템 개발)

  • Kim Man-il;Jeong Gyo-Cheol;Park Chang-Kun
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.361-369
    • /
    • 2004
  • The authors designed a new technique to measure dielectric constant of a soil media by Frequency Domain Reflectometry (FDR) system and its measurement sensor probe with different length such as 7m, 10cm and 15cm for estimating the variations of dielectric constant. Measurement of dielectric constant of soil material is possible to measure an interference wave generated by between incidence wave and reflection wave which are detected to electro-magnetic wave through the directional coupler at the high frequency range,0.1 to 1.7GHz, by FDR system. The obtained experimental results verified that the technique is very promising for non-destructive and continuous soil volumetric water content measurement monitoring in a laboratory. The relationship between the soil volumetric water content and the dielectric constant of soil media (standard sand) was expressed by a single regression ewe independent of soil texture at a small experimental error. Also the derived regression curve coincided well with that obtained by Topp curve.

Analysis on Spatiotemporal Variability of Erosion and Deposition Using a Distributed Hydrologic Model (분포형 수문모형을 이용한 침식 및 퇴적의 시.공간 변동성 분석)

  • Lee, Gi-Ha;Yu, Wan-Sik;Jang, Chang-Lae;Jung, Kwan-Sue
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.11
    • /
    • pp.995-1009
    • /
    • 2010
  • Accelerated soil erosion due to extreme climate change, such as increased rainfall intensity, and human-induced environmental changes, is a widely recognized problem. Existing soil erosion models are generally based on the gross erosion concept to compute annual upland soil loss in tons per acre per year. However, such models are not suitable for event-based simulations of erosion and deposition in time and space. Recent advances in computer geographic information system (GIS) technologies have allowed hydrologists to develop physically based models, and the trend in erosion prediction is towards process-based models, instead of conceptually lumped models. This study aims to propose an effective and robust distributed rainfall-sediment yield-runoff model consisting of basic element modules: a rainfall-runoff module based on the kinematic wave method for subsurface and surface flow, and a runoff-sediment yield-runoff model based on the unit stream power method. The model was tested on the Cheoncheon catchment, upstream of the Yongdam dam using hydrological data for three extreme flood events due to typhoons. The model provided acceptable simulation results with respect to both discharge and sediment discharge even though the simulated sedigraphs were underestimated, compared to observations. The spatial distribution of erosion and deposition demonstrated that eroded sediment loads were deposited in the cells along the channel network, which have a short overland flow length and a gentle local slope while the erosion rate increased as rainfall became larger. Additionally, spatially heterogeneous rainfall intensity, dependant on Thiessen polygons, led to spatially-distinct erosion and deposition patterns.

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF