• Title/Summary/Keyword: submicron particles

Search Result 138, Processing Time 0.027 seconds

Photoluminescence Characteristics of Eu-doped Yttrium Oxide Submicron-sized Particles Prepared by Aerosol Pyrolysis

  • Park, Il-Woo;Park, Chang-Kyun;Lee, Deok-Jin;Yoo, Jea-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • Europium doped yttrium oxide submicron-sized particles were prepared by ultrasonic aerosol pyrolysis. To examine the size effect of submicron-sized-particle, the photoluminescence of the particles was investigated. The particle size was controlled by pH, reaction temperature, molar concentration of yttrium in precursor solution. The PL intensity of submicron-sized particles was decreased with particles size. When the particle size is above about 150 times of Bohr radius of Y$_2$O$_3$, the optical property of the particles shows the bulk characteristics.

Removal characteristics of submicron particles with electrostatic precipitator under $CO_2$ rich condition ($CO_2$ 농후 조건에서 전기집진장치의 Submicron 입자 제거 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Song, Dong-Keun;Jeong, Sang-Hyun;Won, Jong-Oung;Kim, Yong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2116-2121
    • /
    • 2008
  • Removal of particles at rich $CO_2$ condition has been important in the gas cleaning for $CO_2$ capture in Oxy-fuel combustion. Electrostatic precipitators (ESPs) have been widely used to remove particles in exhaust gases from present air combustion. However, few studies on characteristics of ESPs under a $CO_2$ rich gas condition have been conducted. In this study, we investigated integration of electrostatic precipitators (ESP) for removing submicron particles along with corona discharge characteristics and collection efficiency of submicron particles at $CO_2$ rich condition. The overall performance of ESP is represented by collection efficiency as function of energy consumption. The experiment results showed that higher the concentration of $CO_2$ gas, the corona discharge currents were lower at the same applied voltages and the spark over occurred at lower voltages, and the collection efficiency of submicron particles under 50, 80% $CO_2$ conditions was much lower than that under 100% Air.

  • PDF

Influence of gas flow on structural and optical properties of ZnO submicron particles grown on Au nano thin films by vapor phase transport (가스 유입량이 기상이동법으로 금 나노박막위에 성장된 산화아연 입자에 미치는 영향)

  • Kim, So-A-Ram;Nam, Gi-Ung;Kim, Min-Su;Park, Hyeong-Gil;Yun, Hyeon-Sik;Im, Jae-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.211-212
    • /
    • 2012
  • ZnO submicron particles were grown on Au-catalyzed Si substrate by a vapor phase transport (VPT) growth process under different mixture gas ratio at growth temperature of $900^{\circ}C$. The structural and optical properties of the ZnO submicron particles were investigated by field-emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), and photoluminescence (PL). The ZnO submicron particles could be clustered with the $O_2/Ar$ mixture gas ratio(%) higher than 10%, and it was mainly determined by the gas ambient. Particularly, when the $O_2/Ar$ mixture gas ratio was 30%, it was observed the ZnO submicron particles with diameters in the range of 125 to 500 nm and the narrowest full width at half maximum (FWHM) of XRD and PL spectra with $0.121^{\circ}$ and 92 meV, respectively. It was found that the structural and optical properties of the ZnO submicron particles were improved with increasing the $O_2/Ar$ mixture gas ratio through the XRD and PL spectra.

  • PDF

A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - II. Collection Efficiency Characteristics (전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-II. 집진 효율 특성)

  • 김용진;여석준;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.579-587
    • /
    • 2001
  • This study investigates particle collection characteristics of a cylindrical electrostatic precipitator. Experimental work has been made for the submicron particles. The effects of polarity of discharge electrode wire, particle diameter, gas velocity, gas temperature, and specific corona power on the particle collection efficiency are investigated. The efficiency of negative corona is higher than that of positive corona. as the particle diameter increases, the efficiency is decreased when the diameter is in the range of 0.02-0.6 micron, but is increased for the nanometer particles with diameter smaller than 0.02 micron. The efficiency is increased with increase of specific corona power. As the gas temperature increases, overall collection efficiency is increased for a negative corona, but is deceased for a positive corona.

  • PDF

Charge Distribution of Submicron Particles Charged by Spray Electrification or Corona Discharge (분무 및 코로나 방전에 의해 대전된 서브마이크론 입자의 대전량 분포)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jeong-Ho;Lee, Gyu-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.124-132
    • /
    • 2001
  • This paper reports on the charge distribution measurements of submicron particles for three different charging mechanisms, which are spray electrification, bipolar ionization and corona discharge process, respectively. The number of elementary charges per particle was investigated by classifying and counting of a discrete mobility class. Charge distribution measurements were performed with NaCl particles generated from a collision atomizer for 0.01, 0.1, 1% NaCl solutions. Experimental results show than charge level of atomized NaCl particles is high and decreases with increasing the dissolved ion concentration. The charge level of the atomized NaCl particles can be reduced to that o Boltzmann equilibrium conditions by the bipolar ionization(Po(sup)210 bipolar ionizer). The charge level on NaCl particles passing through the corona discharge reactor is much higher than those of atomized or bipolar ionized NaCl particles. The evaluation of these measurements results in charge distribution of the submicron particles.

Synthesis of Submicron Silver Particle Using Room Temperature Ionic Liquids (상온 이온성 액체를 이용한 미세 은 입자 제조)

  • Yoo, Kye Sang
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.14-17
    • /
    • 2012
  • Submicron silver particles were synthesized by chemical reduction with various room temperature ionic liquids. The size and distribution of silver particles were significantly affected by the anion type of ionic liquids and this is mainly attributed to the different abilities of the anions to coordinate with the silver particle, leading to various coagulation of silver particles. Among ionic liquids, 1-butyl-3-methylimidazolium hexafluorophosphate was the most effective to synthesize submicron silver particles.

Removal of Endotoxins and Nucleic Acids Using Submicron-sized Polymeric Particles

  • Kim, Chan Wha;Chokyun Rha
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.3
    • /
    • pp.189-193
    • /
    • 1996
  • Submicron-sized polymeric particles (SSPP) were used to remove nucleic acids and endotoxins from cell lysates. The positively charged SSPP selectively adsorb nucleic acids and endotoxins and form complexes with them. The complexes can be easily removed by sedimentation or centrifugation. The removal of nucleic acids and endotoxins using SSPP also can be accomplished in the presence of cell and cell debris. Therefore, nucleic acids and endotoxins can be removed in an initial step of the down-stream processes. In bakers yeast and E. coli lysate systems, the level of DNA could be reduced more than three orders of magnitudes and endotoxins more than seven orders of magnitudes concurrently willi the cell debris removal process using SSPP.

  • PDF

A Theoretical Study on the Initial Collection Efficiency of Submicron Particles by a Unipolar Charged Fiber (단일 전하로 하전된 단일 섬유에서의 미세입자의 초기 집진효율에 관한 이론적 연구)

  • 오용학;전기준;정용원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.3
    • /
    • pp.259-268
    • /
    • 2001
  • In this study, we have developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber in the electret filters. The particle sizes considered were in the submicron range and thus Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigators experimental data on single fiber efficiency as well as with the calculated results using the existing correlations on single fiber efficiency. It has been shown that simulation results are in good agreement both with the experimental data with those predicted by the correlations.

  • PDF

Nano and Submicron Sized Particle Collection with Various Voltage Waveforms for Dielectric Barrier Discharge Type 2-Stage ESP (유전체 베리어 방전형 2단 전기집진기의 인가전압 파형별 나노 및 서브마이크론 입자 집진 특성)

  • Park, Jae-Hong;Byeon, Jeong-Hoon;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1261-1266
    • /
    • 2004
  • Dielectric Barrier Discharge (DBD) in air, which has been established for the production of large quantities of ozone, is more recently being applied to a wider range of aftertreatment processes for HAPs (Hazardous Air Pollutants). Although DBD has high electron density and energy, its potential use as precharging nano and submicron particles are not well known. In this work, we measured I-V characteristics of DBD and estimated collection efficiency of the particles by DBD type 2-stage ESP. To examine the particle collection with various applied voltage waveforms of DBD for nano and submicron sized, bimodal particles were generated by a electrical tube furnace and an atomizer.

  • PDF

Aspect Ratio Behavior of Grinding Particles with Variation of Particle Size by Wet Grinding (습식분쇄에 의한 입자크기 변화에 따른 분쇄입자의 종횡비 거동)

  • Choi, Jin Sam
    • Korean Journal of Materials Research
    • /
    • v.30 no.5
    • /
    • pp.223-230
    • /
    • 2020
  • As a case study on aspect ratio behavior, Kaolin, zeolite, TiO2, pozzolan and diatomaceous earth minerals are investigated using wet milling with 0.3 mm media. The grinding process using small media of 0.3 pai is suitable for current work processing applications. Primary particles with average particle size distribution D50, ~6 ㎛ are shifted to submicron size, D50 ~0.6 ㎛ after grinding. Grinding of particles is characterized by various size parameters such as sphericity as geometric shape, equivalent diameter, and average particle size distribution. Herein, we systematically provide an overview of factors affecting the primary particle size reduction. Energy consumption for grinding is determined using classical grinding laws, including Rittinger's and Kick's laws. Submicron size is obtained at maximum frictional shear stress. Alterations in properties of wettability, heat resistance, thermal conductivity, and adhesion increase with increasing particle surface area. In the comparison of the aspect ratio of the submicron powder, the air heat conductivity and the total heat release amount increase 68 % and 2 times, respectively.